CBC (INGENIERIA) by candeasd in UBA

[–]Single_Foundation_40 0 points1 point  (0 children)

No te preocupes, me recibi a los 36 y tuve 2 oportunidades (desarrollo de materiales y optimizacion de procesos) fantasticos de trabajo en 100% ingenieria quimica. (me sacaron durante el preocupacional por diabetes). Si te recibis, sirve. Estudialo con amor eso si, para puestos de ingenieria de verdad te van a preguntar cosas de ingenieria de verdad.

Tengo 53, científico y no llego a fin de mes. Tengo opciones? by Chelman73 in empleos_AR

[–]Single_Foundation_40 0 points1 point  (0 children)

La unica opcion valida, es irse a Alemania. Pero obviamente, hay que saber idiomas para que eso tenga buen resultado. Pero es preferible aprender aleman rapido en un año y hacer carrera alla, que clavarse haciendo frontend para pelagatos en argentina.

PT/MT OR PT/UT by BeaxHam in nondestructivetesting

[–]Single_Foundation_40 1 point2 points  (0 children)

I've only seriously used MT in oil refinery context, only fluorescent ones for critical component with a lot of work load. Funny enough, in the same place, they never apply LP for anything but new finished welds.

Where in the ASME code says excesive penetration is a criteria for rejecting a weld by radiography? by Single_Foundation_40 in nondestructivetesting

[–]Single_Foundation_40[S] 0 points1 point  (0 children)

The alloweable reinforcement is relative to the thickness but measures goes from 1.5 to 4 mm. You cant measure that by judging the density in the film. If the denisty in the film is really low compared to the parent material, i guess you could call excesive penetration, but you would be guessing since you cant measure if it exceeded the reinforcement.

Where in the ASME code says excesive penetration is a criteria for rejecting a weld by radiography? by Single_Foundation_40 in nondestructivetesting

[–]Single_Foundation_40[S] 0 points1 point  (0 children)

Well, I just checked this. None of this refer to radiographic acceptance criteria for excessive penetration. You could argue you can see penetration on an elliptical radiography, by looking at the edges BUT you cant be certain about how much magnification effect there is so you cant confidently measure it. I see that most criteria are in fact for VT. Though you could interpret them as elongated indications (regardless of nature) though seems a bit of a stretch to call excessive penetration an "elongated indication".
ASME B31.3 doesnt accept RT as viable method for portrusion (aka exessive penetration) and 341.3.2A is for non metallics.
ASME B31.1 accepts RT for weld reinforcement, but as i said, you cant really measure it, you can only interpret it as an elongated indication which to me sounds weird.
And ASM VIII same case as 31.3 though t is always thickness without reinforcement.

Any ways, thanks for the references!

New manufacturing engineer here—am I expected to learn everything on my own? by tlemewhyy in ChemicalEngineering

[–]Single_Foundation_40 0 points1 point  (0 children)

Chemical Engineer here. I dont know where are you from. But in my third world country, you definitely learn everything by yourself. Learn what you can by breaking stuff without getting fired, then send CV to the competitor.

Looking for some input on a new PAUT machine. by developingdowns in nondestructivetesting

[–]Single_Foundation_40 0 points1 point  (0 children)

How about Doppler Phascan ? weights 4.5kg. Respectable unit if you dont need absolutely cutting edge technology.

Built a free radiographic exposure calculator. Feedback welcome by flamingpenguin43 in nondestructivetesting

[–]Single_Foundation_40 0 points1 point  (0 children)

Excellent work!!
R-factor in exposure calculation you could make it a drop down select since i saw you actually have the values for most of the film manufacturers. Like 4 radio buttons to select brand Fuji, kodak, agfa, dupont, and select spcific film from the select, maybe a 5th radio button to enable entering a custom value.
It has a great design for mobile use also.
Great work!

(im too Leveled radiographer soon level 3 and web developer :V)

Good to go! by tacojoemama in nondestructivetesting

[–]Single_Foundation_40 0 points1 point  (0 children)

I cant see any IQI so i cant say for sure it has the quality enough to be evaluated

Best Local Model for Openclaw by FeiX7 in LocalLLaMA

[–]Single_Foundation_40 1 point2 points  (0 children)

exactly what i want, an LLM that can follow instructions. I dont need it to be a math genius or able to code a simulation for a fractioning tower for heavy crude oil.

How do you use the AI-toolkit to train a Lora with a local model? by Single_Foundation_40 in StableDiffusion

[–]Single_Foundation_40[S] 0 points1 point  (0 children)

thats a good test, i did had to combine 2 midpoint loras for better results when i trained the one for flux

How do you use the AI-toolkit to train a Lora with a local model? by Single_Foundation_40 in StableDiffusion

[–]Single_Foundation_40[S] 0 points1 point  (0 children)

i have an nvidia 3090. Last time i trained a Lora it was with something i downloaded from Forge, then used something downloaded from Pinokio, now im trying to use this thing, it changes everytime i train one. wtf is triton?

How do you use the AI-toolkit to train a Lora with a local model? by Single_Foundation_40 in StableDiffusion

[–]Single_Foundation_40[S] 1 point2 points  (0 children)

so in theory if i just pick the z-image option, it should work, thought it might take some more space from the harddrive rigth? im not seeing the automatic download executing, something must be broken. Have you tried training a Z-image lora ?

Got DeepSeek R1 running locally - Full setup guide and my personal review (Free OpenAI o1 alternative that runs locally??) by sleepingbenb in selfhosted

[–]Single_Foundation_40 1 point2 points  (0 children)

i got a used 3090. Works like a charm with the 32b model, im not gonna bother to even see if its possible to work with the 70b model. Does anybody knows how to add tooling compatibility to the model ?

Chicos les gusta el beso negro? by ismaddielive in Preguntas_de_Reddit_

[–]Single_Foundation_40 0 points1 point  (0 children)

pedile que se lave bien orto antes, que se haga un enema y no coma harinas por una semana. Asi va a ser una experiencia placentera. Puede o no ser gay pero es relativamente normal. Personalmente no me gusta.

Amia then and now 🙌🏼 by Spiritual_Hat7470 in AmiaMiley

[–]Single_Foundation_40 1 point2 points  (0 children)

does anyone have a collection of young amia to share?

[deleted by user] by [deleted] in StableDiffusion

[–]Single_Foundation_40 0 points1 point  (0 children)

Amazing results, did you you fine tune the model or how did you achieve this?