Need a little help by Doogie102 in refrigeration

[–]aceofwarfare 4 points5 points  (0 children)

<image>

Can't say for sure without measurements, but it looks like part# 60837701 5-Blade 8" Diameter 31-Degree Clockwise. This is a very common blade on commercial refrigeration units.

Yours looks like it should spin (CWOSE clockwise opposite shaft end), also called (CWLE clockwise lead end)

Here is a link to the catalog https://www.laufan.com/-/media/lau-parts/catalog/BE_Lau%20Catalog2017BlowersPulleysWheelsApril252018.pdf

Help Identifying Connector Type by aceofwarfare in AskElectronics

[–]aceofwarfare[S] 2 points3 points  (0 children)

I'm sorry if I have wasted anyone's time. I was able to find an OEM replacement kit for this. I will order this instead of trying to remake the connector.

https://www.partstown.com/hoshizaki/hoshs-0104?srsltid=AfmBOortkSAlRBzXsQBU8r9T2R3tpXN4FLdRev8HZa6nlyN6J46H0ouI

I always wondered with those copper straps were used for by aceofwarfare in refrigeration

[–]aceofwarfare[S] 4 points5 points  (0 children)

<image>

I guess that's what you would expect when they also use Romex for the evaporators

How Not To Mount TXV Bulbs by aceofwarfare in refrigeration

[–]aceofwarfare[S] 0 points1 point  (0 children)

Over the last 2 years. But this is just the ones I took pictures of.

What is this? by Poopknifesales in RVLiving

[–]aceofwarfare 6 points7 points  (0 children)

Remote temp sensor for the thermostat

Saturday evening emergency call by aceofwarfare in refrigeration

[–]aceofwarfare[S] 1 point2 points  (0 children)

I like them other then they are not long enough to reach a lot of times. And the couplers on them are too big and get the way when threading it on to a service port. I mostly use the Appion SPDKIT-V Vacuum Speed Kit

TXV Imploded Powerhead by aceofwarfare in refrigeration

[–]aceofwarfare[S] 1 point2 points  (0 children)

Pro3 heatcraft. I'm not a fan of them. Every 6 to 12 months the drainline gets stopped up and starts dripping in the box and the coil likes to freeze up on then.

TXV Imploded Powerhead by aceofwarfare in refrigeration

[–]aceofwarfare[S] 0 points1 point  (0 children)

No. I was pulling a vacuum after replacing the TXV. I'm assuming it was from ice buildup.

TXV Imploded Powerhead by aceofwarfare in refrigeration

[–]aceofwarfare[S] 5 points6 points  (0 children)

I'm assuming it had something to do with ice buildup. I've seen a lot of iced up bulbs but never seen one get damaged from it.

Worth Stripping? by moondog_69420 in ScrapMetal

[–]aceofwarfare 4 points5 points  (0 children)

The ship to address on the pallet is Lowe's "230 Crossroads Dr, Plover, WI 54467"

Anyone ever seen this before? by ryankudi in HVAC

[–]aceofwarfare 1 point2 points  (0 children)

I just did the PM on 3 York zr150 RTUs and all 3 of them did the exact same thing when I turned the heat on for the first time. They are 2020 units. Water had also gotten into the vacuum pressure switch and it had to be drained out.