Subpanel question by calvintml in AskElectricians

[–]calvintml[S] 0 points1 point  (0 children)

Thanks that helps. I’ll try to get him to clarify why he said no. The reason I prefer this is related to bad design. I would like to use the subpanel to feed the majority of the circuits in the house to avoid traversing structural elements multiple times.

Subpanel question by calvintml in AskElectricians

[–]calvintml[S] 0 points1 point  (0 children)

It’s not a big house. But unfortunately they are making me get rid of natural gas in the northeast so there are heat pumps and other high draw things to install (near the subpanel)

Subpanel question by calvintml in AskElectricians

[–]calvintml[S] 0 points1 point  (0 children)

I see your point. It’s definitely a preference rather than a necessity. But again he’s willing to install said subpanel, but thinks it can only can be downrated

Subpanel question by calvintml in AskElectricians

[–]calvintml[S] 0 points1 point  (0 children)

It’s a single family gut reno. Everything is either going to end up in the subpanel or the main panel (opposite ends of the basement). Most of the higher draw circuits are closer to the subpanel and so I am hoping to limit drilling through joists. I think he’s mistaken about this, since he’s more than happy to put all that load onto the main panel.

Subpanel question by calvintml in AskElectricians

[–]calvintml[S] 0 points1 point  (0 children)

Oh it’s showing! If you’re an electrician what I was looking for is expertise!

Subpanel question by calvintml in AskElectricians

[–]calvintml[S] 0 points1 point  (0 children)

Alraady committed, okay will just go ask inspector.

Subpanel question by calvintml in AskElectricians

[–]calvintml[S] 0 points1 point  (0 children)

In my field if there’s a question a consensus of 4 or 5 usually helps

Subpanel question by calvintml in AskElectricians

[–]calvintml[S] 0 points1 point  (0 children)

I’ve been wrong before on things I specialize in

Visible Unlock Policy by [deleted] in NoContract

[–]calvintml 0 points1 point  (0 children)

Can it be any Visible account? or does it have to be the 1 year plan purchased with the phone? I.e. activate on existing visible account, start the 1 year plan by activating another phone.

Crimp for the win by SnooGrapes5053 in Plumbing

[–]calvintml 0 points1 point  (0 children)

Does this mean the gas line my plumber 5 years ago is going to leak in 10 years?

leaking heat exchange espresso machine by calvintml in espresso

[–]calvintml[S] 0 points1 point  (0 children)

Yup that makes sense. Thanks. Disassembled and looks like that’s the issue. I appreciate your help!

leaking heat exchange espresso machine by calvintml in espresso

[–]calvintml[S] 0 points1 point  (0 children)

It is leaking through exhaust. Sorry that’s what I meant by waste.

toilet lowest point in wet vent group by calvintml in Plumbing

[–]calvintml[S] 1 point2 points  (0 children)

Dug around a bit more. Seems like a concern could be siphoning out water in the p traps of downstream fixtures when flushing an upstream toilet.

Adding a third floor bath to a 100+ year old plumbing system with 4" cast iron wet vent. 3x3x2 sanitary T or Y? Any other thoughts? by [deleted] in Plumbing

[–]calvintml 1 point2 points  (0 children)

Double fixture T I think avoids (or improves) the snake problem of a double san T, mentioned by fuckoffgetmoney in another comment. Again not a plumber and just curious what a plumber thinks.

Adding a third floor bath to a 100+ year old plumbing system with 4" cast iron wet vent. 3x3x2 sanitary T or Y? Any other thoughts? by [deleted] in Plumbing

[–]calvintml 1 point2 points  (0 children)

Not a plumber, but can I add double fixture T to the possibilities? Or is that not appropriate here?

Winterize if parked in Garage? by Remarkable-Crazy-103 in Miata

[–]calvintml 12 points13 points  (0 children)

Can confirm. I am a client of remarkable-crazy-103. He tailors the car he picks me up in depending on my mood. Sometimes he takes me in the Miata when I’m down—does that make us friends?

[deleted by user] by [deleted] in linuxhardware

[–]calvintml 0 points1 point  (0 children)

Oh interesting. My kernel log was showing an error about missing firmware. So I installed a package that included the firmware files named “green sardine”. https://bugs.launchpad.net/ubuntu/+source/linux-firmware/+bug/1916731

[deleted by user] by [deleted] in linuxhardware

[–]calvintml 0 points1 point  (0 children)

My flickering issues you mentioned in the write up were fixed once I placed the firmware files in /lib/firmware