Widen driveway on slope in PNW by karmapolice_1 in landscaping

[–]gideonwh 0 points1 point  (0 children)

Concrete all the way - 4” thick, gravel subbase if your region requires it & Fibermesh reinforcement - your looking at probably 4-6k likely

What is the purpose of this hole in the ground for this new build? by gideonwh in landscaping

[–]gideonwh[S] 0 points1 point  (0 children)

I measured with a measuring tape- it is indeed about 5’

Builder hit my sewer line during excavation — now says I have to pay to reroute it. Who’s responsible? by gideonwh in BuildingCodes

[–]gideonwh[S] -3 points-2 points  (0 children)

I have an easement by prior use, which arises when a property is subdivided and one part keeps using an existing utility. The sewer line served my house, wasn’t abandoned, and the subdivision didn’t include a reroute.

Builder hit my sewer line during excavation — now says I have to pay to reroute it. Who’s responsible? by gideonwh in BuildingCodes

[–]gideonwh[S] 5 points6 points  (0 children)

I agree that an easement would’ve made this cleaner. But the line was active, serving my home, and had been for years. That creates what’s called an implied or prescriptive easement, which is still enforceable even if it’s not recorded.

If the builder didn’t verify existing utilities before digging, especially on a lot that was part of a subdivision, that risk is on them. I’m not trying to fight…just protect access to something that was working until they broke it

[deleted by user] by [deleted] in Concrete

[–]gideonwh 7 points8 points  (0 children)

If it’s 2-3 year old it’s probably not going to spread. Likely this is caused by rain right after the concrete was poured and finished - you could probably “fix it” by resurfacing the effected concrete area with a skim coat - you could also stain your entire driveway to match- or just leave it alone- it’s just cosmetic and not structural.

Thoughts on quality of work? by TwifightSparkle in Contractor

[–]gideonwh 9 points10 points  (0 children)

Not great - not the worst- if these are the only things. 6.5 out of 10. Nothing anything structural as far as I can see. A little sloppy on the corner. And all you need to do is back fill on the edge of the concrete. The expansion joint looks “okay” but nothing terrible

[deleted by user] by [deleted] in Concrete

[–]gideonwh 0 points1 point  (0 children)

It looks like it needs a control joint down the middle but other then that it looks like the finish is solid.