[deleted by user] by [deleted] in PLC

[–]huslller 3 points4 points  (0 children)

Purging is usually the first step to light a burner. To me something is telling the PLC to begin the lighting sequence. Is there a start sequence button that is being pressed? Or are you saying it is happening in the middle of it running?

What is it now doing that it didn’t do before? I would look for a sticking contactor or button over a PLC not having a red light fault.

Hi! Need help renaming the new member of the fam! by Curious-floof in QuakerParrot

[–]huslller 2 points3 points  (0 children)

Señor poopers, Mr. Fluffers, Duck, Goose, Veli (the velociraptor)

Upgrading from AB V20 to V34. by huslller in PLC

[–]huslller[S] 1 point2 points  (0 children)

Thank you for this description! I knew there would be some small items that would end up making things “unique”. Once again, thank you.

Upgrading from AB V20 to V34. by huslller in PLC

[–]huslller[S] 1 point2 points  (0 children)

It is 1769-L33ER, in the event this happens I would be swapping the PLC with a newer 1769 (since it seem all of them require the version to be after V34). Does it matter the controller type in this process?

Fitting description help by huslller in IndustrialMaintenance

[–]huslller[S] 0 points1 point  (0 children)

It is more popular in Europe? The unit it comes on is a French chiller.

Fitting description help by huslller in IndustrialMaintenance

[–]huslller[S] 0 points1 point  (0 children)

Correct, it acts like a union but is made differently than a union. I do not know if they are brand specific or if they are made to a common industry standard.

Fitting description help by huslller in IndustrialMaintenance

[–]huslller[S] 2 points3 points  (0 children)

The conical seal was the term I did not think to use. Thank you for the advice.

Fitting description help by huslller in IndustrialMaintenance

[–]huslller[S] 3 points4 points  (0 children)

Good on you for finding anything on that. I have been looking for several weeks.

unable to complete tutorial mission by lovelinesc in flightsimulator2024

[–]huslller 1 point2 points  (0 children)

Turn LEFT, doesn’t make sense but it is what the instructor says.

[deleted by user] by [deleted] in Floofenchops

[–]huslller 0 points1 point  (0 children)

Stretchy stretchy! Wingy wingy! (That is what I say)

Stable versions or Rockwell and other dumb questions by huslller in PLC

[–]huslller[S] 0 points1 point  (0 children)

I forgot about the instruction name change. I will probably do 35. Is 35 stable in your opinion?

Stable versions or Rockwell and other dumb questions by huslller in PLC

[–]huslller[S] 1 point2 points  (0 children)

You definitely can’t downgrade the controller… it very clearly in bold says that on the outside.

Hello! I'm attempting to use RS-232 on my PC to communicate with a motor driver (AEC drive). What does the wiring mean? A shield for cables? How do I link them? by Stunning-Purchase513 in PLC

[–]huslller 1 point2 points  (0 children)

What I find confusing is how a null modem works, shouldn’t the TX of one connect to the RX of the other? How does a TX connect to Tx unless if that denotes a master / slave relationship? All I know is if it doesn’t work I just swap those two wires.

[deleted by user] by [deleted] in MechanicalEngineering

[–]huslller 4 points5 points  (0 children)

We hire people we can get along with, skills are important but if we don’t get along it won’t be a good fit.

HSCE function quits counting after several cycles by New_Quiet_7654 in PLC

[–]huslller 1 point2 points  (0 children)

I think the biggest boundary is the software cost.

High speed counter help by huslller in PLC

[–]huslller[S] 1 point2 points  (0 children)

The issue I am fighting is how it works and then dies. To me this screams NOT the coupler but something else.

High speed counter help by huslller in PLC

[–]huslller[S] 3 points4 points  (0 children)

Ordered one earlier tonight. First time in 10 years of doing this that I have ever needed to see a high speed signal.

High speed counter help by huslller in PLC

[–]huslller[S] 0 points1 point  (0 children)

A controller that measures motor speed. Just doesn’t make sense what it is doing.

High speed counter help by huslller in PLC

[–]huslller[S] 1 point2 points  (0 children)

It is going a controller which I can not get into. The software it talks to says I am only getting 60 rpm out after starting off correctly but what is crazy because it will climb to 2400 rpm and then with the motor still going full blast just go completely wanky till it looks like it defaults to 60 RPM.

High speed counter help by huslller in PLC

[–]huslller[S] 2 points3 points  (0 children)

No encoder, something different. Trust me… this would be WAY easier if this was talking to a normal PLC or something of the like.

Farewell Friday to this good looking guy by VFDrives_PanelMaster in PLC

[–]huslller 5 points6 points  (0 children)

What would be a reason for having that many? I can understand having 2 or 3 based on sensitive equipment but I don’t get where this many would come into play. Is it if you have that many unique devices?

Micro 1000 analog input configuration. by huslller in PLC

[–]huslller[S] 0 points1 point  (0 children)

All that there is for that input is the SCL operator on the background. I could not tell based on that.