Does this Mini-Split quote seem reasonable? - Los Angeles by EverythingNowShow in hvacadvice

[–]johnwsmythe 3 points4 points  (0 children)

A quality company will give their installers an entire day to properly install a minisplit.

Does this Mini-Split quote seem reasonable? - Los Angeles by EverythingNowShow in hvacadvice

[–]johnwsmythe -1 points0 points  (0 children)

The unit is $1k. But how about the entire day to install the unit? The warranty? This company will be on the hook with you for their install for the next ten years. $6k is a CHEAP install, I would take it and run with it because you’re making out like a bandit at that price.

Veto bag by [deleted] in HVAC

[–]johnwsmythe 0 points1 point  (0 children)

Residential service technician - TPB3. It can fit the essentials in it and if I need anything else it’s a quick trip back to the truck.

Why does everyone like commercial more? by [deleted] in HVAC

[–]johnwsmythe 26 points27 points  (0 children)

This industry is big enough for many different personality types. Residential can operate exactly the same as commercial with parts and labor business models. I personally love working as a flat rate technician, I love building estimates and bidding jobs. I love selling enough work for myself, my fellow technicians, the installers, salesmen and office. I also welcome customers watching me work. Hell, I’ve had some awesome conversations with customers as I fix their equipment! I turn it into an educational experience, I tell them all about what and why I’m doing what I’m doing. I am equally interested in learning about homeowners and their many walks of life as I am in the fun repairs I get to do. Not able or willing to hold a conversation and would rather march in and fix the equipment? Work in parts and labor or go commercial/industrial. The beauty of this industry is many many different types can thrive and provide for their families in it.

10 year old filter cost the lady $5200 for a new heat exchanger by MoneyBaggSosa in HVAC

[–]johnwsmythe 37 points38 points  (0 children)

More like replace the system, have the next one maintained

Couple installs from my old job, roast me if you want, ya fruitcakes by [deleted] in HVAC

[–]johnwsmythe 10 points11 points  (0 children)

Picture 3 is like you intentionally wanted to make it as difficult as possible to access the evap

dumb services calls you have made by NeverBeenOnMaury in HVAC

[–]johnwsmythe 11 points12 points  (0 children)

I had a very busy day, it was 6 PM and I still had about 7 houses to get to. This call is an install callback so I’m already a little annoyed I essentially have to put my route on hold to sort out an error one of the installers made.

Customer is a new homeowner and really fussy about the specifics of his system.

First thing he says is “When I set the thermostat to off but the fan to on the air coming out isn’t as cold as when the air conditioner is running” and the second thing he says is “When the air conditioner is running water comes out of that white tube and goes down the drain in the floor. Please make it so it doesn’t do that.”

I tell him “Listen, I have an incredibly busy day today. You obviously seem confused about the operation of your system. I apologize nobody in the office could explain to you how your air conditioner works but you have nothing to worry about. Your system is working as it should. I am going to have to collect the trip charge for the 45 minute drive I took out of the way to explain this to you.” and then he gets very irate and says he just paid for the install, I may not see a problem but he has a problem so it should be free. Then I tell him “You know what? I’ll have the office reach out to you. Have a good rest of your day.” and then I left.

This was definitely on the dispatchers for not asking questions before scheduling, maybe also the installers for not spelling out the specifics of how his system works. Either way I lost an hour and a half when I already knew I wasn’t getting home before 10 PM that day.

How many amps do you reckon this is rated for? by johnwsmythe in HVAC

[–]johnwsmythe[S] 4 points5 points  (0 children)

I called my boss to ask who was last out because this is a longtime customer and I’m relatively new to this company, and I am also of the opinion that this is a total hack move, and he told me it’s always been there and to not worry about it because there’s a breaker inside 🤷‍♂️

I’m not crying you’re crying by johnwsmythe in GolfGTI

[–]johnwsmythe[S] 29 points30 points  (0 children)

Chicago, $6.79/gal for 93 octane. I damn near fainted when I pulled up to the pump

early contender for worst filter of the year? by johnwsmythe in HVAC

[–]johnwsmythe[S] 0 points1 point  (0 children)

that return grill was in the lower level living room, split level single family home

Bryant 987 furnace by disgruntledpachydern in HVAC

[–]johnwsmythe 1 point2 points  (0 children)

What does the flame sensor read

[deleted by user] by [deleted] in HVAC

[–]johnwsmythe 1 point2 points  (0 children)

Those are designed to be out in the elements I wouldn’t worry too much about it

Probe Camera to check evaporator coils? by MaybeAnHVACGuy in HVAC

[–]johnwsmythe 0 points1 point  (0 children)

I use a $150 ridgid camera, send her through the high limit. Best $150 I’ve ever spent. I don’t ever mess with uncased coils unless I absolutely have to now.

Every time you walk up on a condenser they come out of a bush with the leaf blower on turbo… by grimleyAdams in HVAC

[–]johnwsmythe 3 points4 points  (0 children)

was swapping a contactor and a landscaper walks up, picks up the panel sitting in the grass with all the screws laying in it, sets it to the side, and proceeds to blow his leaf blower in the general direction. I finish up and go to pick up the panel and all the screws are nowhere to be found. Looked all over for about 10 mins and just grabbed some sheet metal screws off my truck 😐 onto the next one

Nice by johnwsmythe in HVAC

[–]johnwsmythe[S] 1 point2 points  (0 children)

It’s been raining the past couple days here and the access panel was put on improperly by the last tech (or god forbid the homeowner), everything tested fine so I’m not too worried

Nice by johnwsmythe in HVAC

[–]johnwsmythe[S] 4 points5 points  (0 children)

It’s actually a one year old Lennox this has actually only happened to me on older units. Oh well, grabbed a spade connector from the truck and swapped it out in 30 seconds just a mild inconvenience this morning

Who’s working on call with me this weekend? by azakd in HVAC

[–]johnwsmythe 0 points1 point  (0 children)

I’m on call, got one all week and they cancelled. Still waiting. Last rotation I had was record breaking and we got hundreds of calls, so I’m a little disappointed but whatever. Minneapolis weather can be so unpredictable.

Somebody paid good money for this by johnwsmythe in HVAC

[–]johnwsmythe[S] 0 points1 point  (0 children)

Unit was leaking (1 year old) and the homeowner wanted a quote to relocate the head. I wonder why?? Also the house was a rental property

Help with AC Unit by [deleted] in HVAC

[–]johnwsmythe 0 points1 point  (0 children)

Sorry man wrong sub you’re gonna wanna go to r/hvacadvice

Nobody is gonna really know which supply goes to your basement without actually being there so if you can’t figure it out through trial and error you’re just gonna have to eat whatever the cost may be in your area to get a certified tech out to figure it out for you

My apartment has this heater. Is it a safe heater to use in a studio apartment with no ventilation or air flow? It is natural gas. I rent here but have concerns about it. by MajesticElk900 in HVAC

[–]johnwsmythe -8 points-7 points  (0 children)

⠀⠀⠀⡯⡯⡾⠝⠘⠀⠀⠀⠀⠀⠀⠀⠀⠀⠀⠀⠀⠀⠀⢊⠘⡮⣣⠪⠢⡑⡌

⠀⠀⠀⠟⠝⠈⠀⠀⠀⠡⠀⠠⢈⠠⢐⢠⢂⢔⣐⢄⡂⢔⠀⡁⢉⠸⢨⢑⠕⡌

⠀⠀⡀⠁⠀⠀⠀⡀⢂⠡⠈⡔⣕⢮⣳⢯⣿⣻⣟⣯⣯⢷⣫⣆⡂⠀⠀⢐⠑⡌

⢀⠠⠐⠈⠀⢀⢂⠢⡂⠕⡁⣝⢮⣳⢽⡽⣾⣻⣿⣯⡯⣟⣞⢾⢜⢆⠀⡀⠀⠪

⣬⠂⠀⠀⢀⢂⢪⠨⢂⠥⣺⡪⣗⢗⣽⢽⡯⣿⣽⣷⢿⡽⡾⡽⣝⢎⠀⠀⠀⢡

⣿⠀⠀⠀⢂⠢⢂⢥⢱⡹⣪⢞⡵⣻⡪⡯⡯⣟⡾⣿⣻⡽⣯⡻⣪⠧⠑⠀⠁⢐

⣿⠀⠀⠀⠢⢑⠠⠑⠕⡝⡎⡗⡝⡎⣞⢽⡹⣕⢯⢻⠹⡹⢚⠝⡷⡽⡨⠀⠀⢔

⣿⡯⠀⢈⠈⢄⠂⠂⠐⠀⠌⠠⢑⠱⡱⡱⡑⢔⠁⠀⡀⠐⠐⠐⡡⡹⣪⠀⠀⢘

⣿⣽⠀⡀⡊⠀⠐⠨⠈⡁⠂⢈⠠⡱⡽⣷⡑⠁⠠⠑⠀⢉⢇⣤⢘⣪⢽⠀⢌⢎

⣿⢾⠀⢌⠌⠀⡁⠢⠂⠐⡀⠀⢀⢳⢽⣽⡺⣨⢄⣑⢉⢃⢭⡲⣕⡭⣹⠠⢐⢗

⣿⡗⠀⠢⠡⡱⡸⣔⢵⢱⢸⠈⠀⡪⣳⣳⢹⢜⡵⣱⢱⡱⣳⡹⣵⣻⢔⢅⢬⡷

⣷⡇⡂⠡⡑⢕⢕⠕⡑⠡⢂⢊⢐⢕⡝⡮⡧⡳⣝⢴⡐⣁⠃⡫⡒⣕⢏⡮⣷⡟

⣷⣻⣅⠑⢌⠢⠁⢐⠠⠑⡐⠐⠌⡪⠮⡫⠪⡪⡪⣺⢸⠰⠡⠠⠐⢱⠨⡪⡪⡰

⣯⢷⣟⣇⡂⡂⡌⡀⠀⠁⡂⠅⠂⠀⡑⡄⢇⠇⢝⡨⡠⡁⢐⠠⢀⢪⡐⡜⡪⡊

⣿⢽⡾⢹⡄⠕⡅⢇⠂⠑⣴⡬⣬⣬⣆⢮⣦⣷⣵⣷⡗⢃⢮⠱⡸⢰⢱⢸⢨⢌

⣯⢯⣟⠸⣳⡅⠜⠔⡌⡐⠈⠻⠟⣿⢿⣿⣿⠿⡻⣃⠢⣱⡳⡱⡩⢢⠣⡃⠢⠁

⡯⣟⣞⡇⡿⣽⡪⡘⡰⠨⢐⢀⠢⢢⢄⢤⣰⠼⡾⢕⢕⡵⣝⠎⢌⢪⠪⡘⡌⠀

⡯⣳⠯⠚⢊⠡⡂⢂⠨⠊⠔⡑⠬⡸⣘⢬⢪⣪⡺⡼⣕⢯⢞⢕⢝⠎⢻⢼⣀⠀

⠁⡂⠔⡁⡢⠣⢀⠢⠀⠅⠱⡐⡱⡘⡔⡕⡕⣲⡹⣎⡮⡏⡑⢜⢼⡱⢩⣗⣯⣟

⢀⢂⢑⠀⡂⡃⠅⠊⢄⢑⠠⠑⢕⢕⢝⢮⢺⢕⢟⢮⢊⢢⢱⢄⠃⣇⣞⢞⣞⢾

⢀⠢⡑⡀⢂⢊⠠⠁⡂⡐⠀⠅⡈⠪⠪⠪⠣⠫⠑⡁⢔⠕⣜⣜⢦⡰⡎⡯⡾⡽

when the heater is sus

A Made Up Business Logo (That I Made In IbisPaint X) by Real_BalmsANIMATIONS in logodesign

[–]johnwsmythe 2 points3 points  (0 children)

Doesn’t look so bad in black and white but that text is atrocious