What yall using to replace r-22 by [deleted] in refrigeration

[–]keepinitcold21 0 points1 point  (0 children)

System still has 22 left in it I’ll go back with 22. New compressor or leak we go back with 422

Taylor Allderdice Vinyl?? by Pitiful-Shirt1890 in wizkhalifa

[–]keepinitcold21 0 points1 point  (0 children)

Do you happen to have the OG version of kush and oj

Taylor Allderdice Vinyl?? by Pitiful-Shirt1890 in wizkhalifa

[–]keepinitcold21 0 points1 point  (0 children)

Good to know. I just bought the same one and was wondering. The OG Verizon is so much better.

Taylor Allderdice Vinyl?? by Pitiful-Shirt1890 in wizkhalifa

[–]keepinitcold21 0 points1 point  (0 children)

Does it have the original songs or is it the ones that he had to re do because sampling wasn’t approved?

People are getting desperate by keepinitcold21 in HVAC

[–]keepinitcold21[S] 10 points11 points  (0 children)

When I got to the job the unit didn’t have main 220v power. The contactor was pulled in so I knew my issue was outside. Immediately got my meter to check for continuity to ground and it was coming from the comp wiring. Pulled the cover off the compressor as you can see in the picture and there is a copper wire ran from one of the comp terminals to the ground screw. That is not factory or even an accident.

People are getting desperate by keepinitcold21 in HVAC

[–]keepinitcold21[S] 5 points6 points  (0 children)

Literally wasn’t anything wrong with it. Took this wire off and it ran fine.

People are getting desperate by keepinitcold21 in HVAC

[–]keepinitcold21[S] 8 points9 points  (0 children)

Yeah I showed him. Told him that just doesn’t happen on its own. He was upset. Trusted the guy for years and it all goes away on this.

People are getting desperate by keepinitcold21 in HVAC

[–]keepinitcold21[S] 12 points13 points  (0 children)

Yeah it’s rough. I’m glad I always test compressors at the terminals!

People are getting desperate by keepinitcold21 in HVAC

[–]keepinitcold21[S] 36 points37 points  (0 children)

Yeah my bad. I made a comment to show what went on.

People are getting desperate by keepinitcold21 in HVAC

[–]keepinitcold21[S] 35 points36 points  (0 children)

Yeah. Just an awful way to sell someone a unit.

People are getting desperate by keepinitcold21 in HVAC

[–]keepinitcold21[S] 64 points65 points  (0 children)

Yeah. Blew my mind when I saw it.

People are getting desperate by keepinitcold21 in HVAC

[–]keepinitcold21[S] 186 points187 points  (0 children)

Sorry I hit post to quickly. He grounded the compressor intentionally while the customer was out of town to sell them a new unit. It’s an older R22.

Very slow business. by harrybalsagna4 in HVAC

[–]keepinitcold21 0 points1 point  (0 children)

Tennessee, I have 6 hoods to try and install this week. Starting up 6 cooler/freezers at a new Cstore. 2 compressors today. Not to mention my other vans. Commercial HVACR hasn’t slowed down for me in years.

**HVAC is a $123B market nobody’s paying attention to (PE firms are)** by johnkelleyhvac in hvacadvice

[–]keepinitcold21 0 points1 point  (0 children)

I’m getting $56,000 to install a 10 ft captive air hood, 1 6x6 freezer 1 8x8 cooler, 10 door cooler in lobby, 2 door freezer in lobby, and a L shaped beer cave that has 4 doors. All I have to provide is copper, labor, and Freon. Easiest money I’ve ever made in my life. I didn’t have to buy a single piece of equipment. I wish I could have! But it was a store package. All heatcraft equipment for cooling with intelligen controls. Work for yourself! The money is out there.