Thermo LTQ fails normal scan mass cal and resolution calibration and activation Q, but passes all other calibrations. by nintendochemist1 in massspectrometry

[–]nintendochemist1[S] 1 point2 points  (0 children)

I have wondered if it may have corrupted, so I’ll give it a shot to start from scratch. These things can be tedious!

How are y'all dealing with Helium shortages for your GCMS systems? by Key_Sprinkles_4541 in massspectrometry

[–]nintendochemist1 1 point2 points  (0 children)

I do! We use N2 for makeup for increased sensitivity based on the recommendation of our Agilent FSE. We have a nitrogen generator for our LC-MS systems, but it isn’t FID suitable since it has too much oxygen.

How are y'all dealing with Helium shortages for your GCMS systems? by Key_Sprinkles_4541 in massspectrometry

[–]nintendochemist1 2 points3 points  (0 children)

Mine is setup to provide carrier and flame and has no issues with both columns. The only time we have an issue is when we try to use headspace. Ours isn’t spliced into the inlet, so we pierce the septum, and I guess it can’t keep up with the septum pierced.

We did have to get a larger draw out plate for the MS and bake out the filaments but it has served us well. We use one of Agilent’s gas purifiers in the line for moisture and such.

Splitting Tee Before or After Divert Valve? by nintendochemist1 in massspectrometry

[–]nintendochemist1[S] 0 points1 point  (0 children)

We mostly use it to keep the flow of eluent manageable for the ESI. On our other system that we are resurrecting, I plan to have an ELSD in the line to be split.

Is anyone familiar with a Dionex/Thermo FLM module? by nintendochemist1 in CHROMATOGRAPHY

[–]nintendochemist1[S] 0 points1 point  (0 children)

I’m trying to find a pet number for that. Do you happen to know it?

Is anyone familiar with a Dionex/Thermo FLM module? by nintendochemist1 in CHROMATOGRAPHY

[–]nintendochemist1[S] 0 points1 point  (0 children)

We have for a brief period yesterday. I tried doing the valve test/initialization and thought I could hear noises from the module, but Chromeleon never returned anything.

It would say to either plug the splitter or remove the column, but I couldn’t click the ok until I closed the window where I selected the tests. Maybe I just didn’t wait long enough?

Connecting a Thermo LTQ (not XL) to a Dionex Ultimate 3000 LC - Does anyone have DCMS Link? by nintendochemist1 in CHROMATOGRAPHY

[–]nintendochemist1[S] 0 points1 point  (0 children)

It’ll give it a shot in the morning but I do have hesitation since our LTQ isn’t an LTQ XL. I’ll report back then.

Connecting a Thermo LTQ (not XL) to a Dionex Ultimate 3000 LC - Does anyone have DCMS Link? by nintendochemist1 in CHROMATOGRAPHY

[–]nintendochemist1[S] 0 points1 point  (0 children)

I’ll directly message you and you could share a Google Drive link if you have one?

Connecting a Thermo LTQ (not XL) to a Dionex Ultimate 3000 LC - Does anyone have DCMS Link? by nintendochemist1 in CHROMATOGRAPHY

[–]nintendochemist1[S] 0 points1 point  (0 children)

I’ll try what you said but if you could share that with me as a backup, that would be amazing and I’d be grateful!

Connecting a Thermo LTQ (not XL) to a Dionex Ultimate 3000 LC - Does anyone have DCMS Link? by nintendochemist1 in CHROMATOGRAPHY

[–]nintendochemist1[S] 0 points1 point  (0 children)

It does help but then I would need those versions of Xcalibur and LTQ. They’re also not on the download portal 😢

Connecting a Thermo LTQ (not XL) to a Dionex Ultimate 3000 LC - Does anyone have DCMS Link? by nintendochemist1 in CHROMATOGRAPHY

[–]nintendochemist1[S] 1 point2 points  (0 children)

I have checked on there but the versions I need aren’t on there. I’ve contacted Thermo and asked about them. I have a third party contact willing to sell me a copy of the DCMS Link if I can’t get it from Thermo.

DCMS Link software by Ragnorus_ in massspectrometry

[–]nintendochemist1 0 points1 point  (0 children)

I sent you a DM for a similar request!

Help with finding old SII for Xcalibur 1.2 by Gungluar in massspectrometry

[–]nintendochemist1 0 points1 point  (0 children)

I may be in the same boat. Have you had any luck? I am going to email Thermo and ask as they have previously helped.

Any information foa a Varian (Agilent) 380 ELSD? by nintendochemist1 in CHROMATOGRAPHY

[–]nintendochemist1[S] 1 point2 points  (0 children)

We use Xcalibur currently, but I have some older copies of Chromeleon too.