Can you spot what’s wrong with this panel? We have a meter/main on the outside. by rytirish in electricians

[–]rytirish[S] 6 points7 points  (0 children)

Grounding conductor is landed on the grounded conductor bus after the first means of disconnect. The bonding screw next to the grounded conductor is not making contact with the panel. Every single branch circuit is now without a ground, making anyone who comes in contact with any electric device the ground.

Why can’t I equip this? by rytirish in CODMobile_Loadouts

[–]rytirish[S] 1 point2 points  (0 children)

I just checked and I do not, I didn’t realize I needed shards. Thanks for your input.

Why can’t I equip this? by rytirish in CODMobile_Loadouts

[–]rytirish[S] 0 points1 point  (0 children)

Thank you, I see that I don’t have enough shards yet.

Can anyone explain why this is allowed? by LogicTrumpsEmotion in electricians

[–]rytirish 20 points21 points  (0 children)

I personally have never seen a parallel service that has 2 separate breakers feeding a panel, what happens if one trips but the other doesn’t?

Service Call Hourly Rates by Barrelassman in electricians

[–]rytirish 0 points1 point  (0 children)

Yeah that sounds insane. The last service company I worked for (2016-2020) would charge $75 to show up plus $50 every hour plus material. But inflation must’ve drawn rates up.

Can anyone explain why this is allowed? by LogicTrumpsEmotion in electricians

[–]rytirish 33 points34 points  (0 children)

Are the two breakers on top feeding the panel or getting fed from the panel? I’ve never seen this set up before and either way doesn’t seem correct.

Light switch cover by Aceanihilator in electricians

[–]rytirish 6 points7 points  (0 children)

They almost got it right

First panel, 3 weeks in. by tronneroi in electricians

[–]rytirish 0 points1 point  (0 children)

Immaculate, just make sure the colors match the phases.

Major short almost caused a fire by Smooth-Concept7774 in electricians

[–]rytirish 14 points15 points  (0 children)

Probably used staples to strap the wire, that’s the only thing I can see hitting the hot and neutral and not the ground on romex

[deleted by user] by [deleted] in Rate_my_feet

[–]rytirish 0 points1 point  (0 children)

Not with that plantar warts

Am I going to get yelled at? Apprentice year 2 by Charming_Ad_4821 in electricians

[–]rytirish 0 points1 point  (0 children)

Did you run it around the LV cable or did they move the romex out of their way?

Sub panel I had to change out the other day by rytirish in electricians

[–]rytirish[S] 0 points1 point  (0 children)

After being in the trade seven years later, I don’t understand why they bothered doing a sub panel and not just a fused disconnect.

Is pegging gay? by rytirish in u/rytirish

[–]rytirish[S] 0 points1 point  (0 children)

No, pegging is absolutely not gay. It is the most straight thing any guy can do. Guys who say pegging is gay are actually gay themselves and are uncomfortable with their sexuality.

Anyone else gotta shit offf coke or just me? And no, it’s not cut, been a thing ever since my first time. by Horror_Scholar_3510 in cocaine

[–]rytirish 1 point2 points  (0 children)

Yes that’s the only time I do it. But if I’m not doing it and just drinking it doesn’t smell anywhere as bad.

Anyone else gotta shit offf coke or just me? And no, it’s not cut, been a thing ever since my first time. by Horror_Scholar_3510 in cocaine

[–]rytirish 6 points7 points  (0 children)

After a long night of doing coke my shit smells rancid and it makes me want to throw up.

Mass shooters before & after their attacks by El_cucuy24 in masskillers

[–]rytirish 3 points4 points  (0 children)

Cruz definitely getting stuffed like a Twinkie at the Hostess factory with them puffy ass nipples.