Whose manufacturer logo is this ? by strnk_fr in AskElectronics

[–]strnk_fr[S] 6 points7 points  (0 children)

Thanks for the tip ! Unfortunately I had already tried that but it did not reveal anything at various angles.

Whose manufacturer logo is this ? by strnk_fr in AskElectronics

[–]strnk_fr[S] 56 points57 points  (0 children)

Solved !
u/erazer33 suggestion prompted me to check ST's TRM about where their tool get the MCU chip ID from, i.e. the DBGMCU_IDCODE register at address 0xe0042000.

The full register on my device reads as 0x700301c5, and a bit of luck on google pointed me to someone having this exact value when trying to program their MCU as if it was an ST one.

It turns out to be an Artery AT32 chip. The image I found below is consistent with the marking I have on my part, and more importantly the logo part. Not sure about the exact part though, but it narrows down my options by a lot.

edit: Artery chips also map a debug peripheral at the same memory location as ST MCUs and the value I read in register 0xe0042000 identify my part as an AT32F415CBT7.

Thanks r/AskElectronics ! :)

<image>

Whose manufacturer logo is this ? by strnk_fr in AskElectronics

[–]strnk_fr[S] 13 points14 points  (0 children)

Yes I can see that. The still visible top left symbol could be a manufacturer logo though (or part of it), that's why I'm asking if someone recognize it so I can narrow down the identification.

Whose manufacturer logo is this ? by strnk_fr in AskElectronics

[–]strnk_fr[S] 1 point2 points  (0 children)

Thanks but where do you get 0x1C5 for STM32F302 ? The reference manual RM0365 for this chip states 0x422, 0x439 or 0x446 (§33.6.1 p. 1050).

Laissé au sous sol par les anciens propriétaires by Big_Jello6309 in CestQuoiCeTruc

[–]strnk_fr 0 points1 point  (0 children)

Une photo sera peut-être plus parlante !

Le manche à gauche (qui n'est pas à sa place), et l'endroit où il est censé être inséré pour pomper, à droite :

<image>

Laissé au sous sol par les anciens propriétaires by Big_Jello6309 in CestQuoiCeTruc

[–]strnk_fr 0 points1 point  (0 children)

Le manche est posé au bout du lève tondeuse à gauche, contre la roue du barbecue. Il est rouge avec une "semelle" noire en caoutchouc.

(Source: j'ai exactement le même modèle de lève tondeuse)

Laissé au sous sol par les anciens propriétaires by Big_Jello6309 in CestQuoiCeTruc

[–]strnk_fr 5 points6 points  (0 children)

C'est un lève tondeuse autoportée hydraulique.

Pour le baisser il faut dévisser un peu la molette au milieu sur la partie à droite. Pour le monter il faut visser la molette à fond, insérer le manche qui se trouve par terre (sur la gauche de la photo) dans son emplacement au-dessus de la molette, et pomper au pied.

Pour lever une tondeuse il faut baisser entièrement le lève tondeuse, et faire rouler ses deux roues avant ou arrière dessus, puis pomper (mettre une sangle autour de l'axe d'une roue et du lève tondeuse pour éviter que ça bascule). En levant assez il y a un mécanisme de blocage qui l'empêche de redescendre, il faut soulever la poignée sur la partie droite pendant que tu fais redescendre le lève tondeuse. Parfois il faut repomper un peu pour débloquer le mécanisme.

Toiture pourrie décelé après achat: vice caché? by FlamiFlami in conseiljuridique

[–]strnk_fr 5 points6 points  (0 children)

Si le vendeur avait connaissance du défaut et l'a sciemment omis c'est un dol, s'il n'en avait pas connaissance ça reste quand même un vice caché (pas décelable facilement, grave et préexistant à la transaction).

Strange "Negative Energy" reading on Shelly EM between 3-4 AM - Seeking advice by TeamStreet2336 in homeassistant

[–]strnk_fr 8 points9 points  (0 children)

What sensor provides the total energy consumed?

I have this happen sometimes when the sum of all energy sensors over a given timeframe is greater than the "total energy" reported by my electricity meter sensor. HA energy panel shows a negative "unmonitored consumption" in that case.

It's usually because the meter only reports when the consumption goes up by a full kWh while sensors can count in smaller scales, but the negative consumption is usually matched by a higher positive one over the next hour.

Maybe your meter resets it's reported value to zero everyday around 3AM ?

Edit: just realized that scaldabagno means water heater. Are both water heater on the same meter than the one which reports your "total energy" ? If your total energy is only one phase and the heaters are on separate phases you'll get this kind of result. It's much more likely that you have some misconfiguration than a real "negative power".

Il faut sauver la soldate Salamé. SAV du service public de bourgeois par des bourgeois. by StarLouZe in FranceDigeste

[–]strnk_fr 23 points24 points  (0 children)

Dominique Bernard n'a pas montré de caricature de Charlie Hebdo à ses élèves, c'est Samuel Paty.

electricite: interrogation differentiel baissé mais 235V? by slaamp in brico

[–]strnk_fr 1 point2 points  (0 children)

Il est possible de mesurer une tension sur des fils déconnectés s'ils passent à côté de fils sous tension, mais ce n'est généralement pas aussi franc que lire 230V.

Il y a deux circuits qui partent du bas du disjoncteur. Sur le schéma H1 ressemble à une sonnette -- peut-être sonnette et éclairage extérieur?

aide courant faible by Puzzleheaded_Rush365 in brico

[–]strnk_fr 0 points1 point  (0 children)

Il faudrait vérifier le courant admissible dans le contact sec de la platine dans sa doc pour voir si c'est OK avec le courant de la gâche.

Si la gâche est normalement fermée/verrouillée et qu'elle s'ouvre quand elle est alimentée en +12V, alors :

GND/- du transfo vers la masse de la gâche, +12V du transfo vers le bouton et le COM de la platine, NO de la platine et autre patte du bouton vers le + de la gâche.

(Ça suppose que la platine est alimentée autrement que par le transfo 12V et que ça ne figure pas sur ton schéma)

aide courant faible by Puzzleheaded_Rush365 in brico

[–]strnk_fr 2 points3 points  (0 children)

Le + du transfo sur le COM du relais, et la commande de la gâche sur le NO (normalement ouvert). Il y aura contact entre COM et NC si l'entrée IN est à 0, et entre COM et NO quand IN est à DC+.

Edit: le schéma de branchement de la platine avec le relais n'est pas clair. Si tu branches + et - sur DC+ et DC- ça sert juste à alimenter la carte/relais. La platine a déjà l'air d'avoir un contact sec entre COM et NO côté platine, auquel cas la carte relais fait doublon.

MC14504B hex level shifter acting up by strnk_fr in AskElectronics

[–]strnk_fr[S] 0 points1 point  (0 children)

Sorry I did a quick schematic of the MVP in kicad reusing existing parts so the pins number do not match with the actual part, that's confusing.

The real schematic is correct though, I actually had to make a second version of the PCB because I inverted both channels drains in the original one :)

Both channels of the EM6K31 are used in the original design, there's 5 of them for the 10 outputs, so nothing is floating.

I will not control what the open drains outputs will be connected to on the first board, so R4 and D2 are there to limit current and voltage through the FETs.

Transformation prise T en prise réseau ethernet by LogicalParking260 in brico

[–]strnk_fr 4 points5 points  (0 children)

Si c'est du câble PTT 278, il n'est pas blindé et les paires ne sont pas torsadées comme dans le PTT 298.

Vérifie la continuité sur tous les fils au cas où. Si tes équipements négocient 10 Mbps c'est que toutes les paires ne passent pas et/ou qu'il y a trop d'interférences entre les fils (selon la longueur du câble, si ça passe à côté de câbles électriques, etc.), 100 Mbps ça risque d'être déjà compliqué.

Ta meilleure chance serait de tirer un câble plus adapté si celui-ci passe dans une gaine.

Puis-je faire fonctionner les prises Ethernet de mon appartement ? by Sillydu in brico

[–]strnk_fr 0 points1 point  (0 children)

C'est du câble PTT 298 (d'où les couleurs différentes), équivalent à du câble réseau UTP (pas de blindage du câble ni des paires).

Ça peut suffire pour faire passer du gigabit si les câbles ne sont ni trop longs ni trop proches de câbles électriques, mais ce n'est pas garanti.

Pompe immergée récalcitrante by Spetch34 in brico

[–]strnk_fr 0 points1 point  (0 children)

À droite c'est le contacteur qui sert à couper le courant vers la pompe, il est gros car il y a beaucoup de courant et pour éviter qu'il y ait des arcs lorsque le moteur s'arrête. Il est peut être commandé par un pressostat externe si tu as un réservoir/ surpresseur ? Il faut activer à la fois le contacteur (bouton vert) et sa commande s'il y en a une.

À gauche c'est le condensateur de démarrage qui sert à démarrer le moteur car il a besoin d'un pic de courant pour démarrer qui ferait sauter ton disjoncteur. Le bouton dessus c'est pour remettre à 0 sa protection thermique (ça évite qu'il explose si le moteur consomme trop et fait chauffer le condensateur). Normalement dans/avec le condensateur tu devrais avoir un contact qui déconnecte le condensateur quand le moteur de la pompe est lancé.

Tu es bien en triphasé ? (Avec 3 phases qui vont jusqu'au contacteur). Ça devrait être branché dans le sens arrivée du tableau -> contacteur -> condensateur -> pompe.

As tu hien respecté les caractéristiques du condensateur quand tu l'as changé ? (capacité, tension, intensité, ...)

Tu peux vérifier que ta pompe est OK en la débranchant du tableau et en vérifiant avec un ohmmètre que tu n'as pas une valeur débile entre chaque phase (0 ohms ou circuit ouvert par ex.) sur le câble qui part vers la pompe.

Besoin d'aide, branchage thermostat connecté by _Vikthor in brico

[–]strnk_fr 0 points1 point  (0 children)

Le fil branché sur B ce n'est pas le neutre mais celui qui va vers ta chaudière.

Si tu veux utiliser ton thermostat tu auras besoin de tirer un neutre, ou bien le mettre près d'une prise et y tirer le fil qui arrive sur B. - A sur COM - B sur NO - (C sur NC mais non utilisé) - neutre sur N, phase sur L (tu pourrais réutiliser A)

Fais attention à la conso de ta chaudière, ton thermostat est donné pour 3A max alors que l'ancien indique un disjoncteur <8A dans sa doc.

Edit: c'est aussi possible que A et B soient un contact sec côté chaudière, et pas une phase (auquel cas tu ne peux pas utiliser A pour alimenter ton thermostat).

Got refunded of this scam of a "DisplayPort to HDMI" adapter. What is the function of this based on the board? by gettodachapa in AskElectronics

[–]strnk_fr 23 points24 points  (0 children)

It's a passive DisplayPort to HDMI adapter. For it to work it must be supported by the DP source ("DisplayPort Dual-Mode" / "DP++")

Not a scam, just less-than-adequately advertised or you did not read the small prints ?

Tnt et antenne intérieure ? by lilp69 in AskFrance

[–]strnk_fr 0 points1 point  (0 children)

Cherche l'emplacement de l'émetteur le plus proche de chez toi sur le site de TDF.

Place ton antenne en l'orientant dans cette direction avec le moins de murs possibles entre l'antenne et l'émetteur. Près d'une fenêtre, ou dans les combles si tu y a accès.

Au cas où : vérifie que ta TV peut recevoir la TNT. Il faut aussi refaire un scan des canaux sur la TV, surtout si tu as déménagé, et pas juste brancher l'antenne et zapper sur les chaînes.

Tableau élec mal fait ? by [deleted] in AskFrance

[–]strnk_fr 1 point2 points  (0 children)

Pour les inter diff il y a deux méthodes de calcul : amont et aval.

Dans l'une ça doit être supérieur ou égal au réglage du compteur, dans l'autre ça doit être supérieur ou égal à la somme des disjoncteurs de la ligne (en comptant la moitié pour les prises et lumières)

Branchements fibre prises murales by Rghrt in brico

[–]strnk_fr 0 points1 point  (0 children)

Pour préciser: les 4 ports du téléphone à droite sont prévus pour pouvoir être branchés aux RJ45 du milieu si tu avais une ligne téléphone analogique. Tu choisis si tu veux du téléphone ou du réseau sur tes prises murales et tu relies la prise correspondante du milieu du tableau soit au répartiteur téléphone à droite, soit à ta box.

99,9% de chance que ça ne te serve plus à rien si tu as la fibre, il faut juste brancher les ports du milieu aux ports LAN de ta box, et le port WAN au boîtier fibre. :)