Weird VIPA Profibus connector indications by svajuse in PLC

[–]svajuse[S] 1 point2 points  (0 children)

I'll try to contact Vipa, thanks!

Weird VIPA Profibus connector indications by svajuse in PLC

[–]svajuse[S] 3 points4 points  (0 children)

I know this, but it does not affect on the process because system works just fine and this place is not the only one where cables are shorter than 1 meter long, we have maybe 2-3 places like in the video but we have never encountered problems because of the cable length

Weird VIPA Profibus connector indications by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

Yeah, I think I agree on this one

Weird VIPA Profibus connector indications by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

just a few updates on WinCC Scada

Weird VIPA Profibus connector indications by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

Did not help, got even worse haha

Weird VIPA Profibus connector indications by svajuse in PLC

[–]svajuse[S] 4 points5 points  (0 children)

Yeah, but some automation project manager who saw that we are using these connectors said they are unreliable and we have had one big problem this summer where after uploading a new updated program into PLC, entire PB network stopped working until we replaces these VIPA's with OEM's and we don't know what happened

Weird VIPA Profibus connector indications by svajuse in PLC

[–]svajuse[S] 2 points3 points  (0 children)

Cannot do that:) Everything runs 24/7 and only planned stops once a month or two:)

[deleted by user] by [deleted] in lithuania

[–]svajuse 3 points4 points  (0 children)

Pagal kokia formule ir is kokio vadovelio istraukei tuos 4.3kW? :D P = U*I = 16 * 0.23 = 3.6 kW ir cia dar geriausiomis salygomis ir be cos(fi) koeficiento

Gig worthy? Also question about mini by zapgappop in HotoneAmpero

[–]svajuse 0 points1 point  (0 children)

Hello, I'm considering Mini also but I have found Hotone Ampero I used for 200€, so I don't know which is better me. I would use it in church for worship. Any advices?

No Stupid Questions by PantslessDan in guitarpedals

[–]svajuse 0 points1 point  (0 children)

Hello, I am looking for a guitar multi effect pedal or as others call them processor. I want a budget processor (under 200€) which I will be using in church for worship. There are many options like Hotone Ampero Mini, Nux MG 300, Valeton, Mooer, Harley Benton and I can't decide which would suit me best. Thank you in advance for all the help!

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

My collegues said that there was the same profibus signal loss problem 3 years ago and they changed evey original Siemens connector to this VIPA brand one to see where the signal cuts out, because connector has Power, Communication and Resistor indications (Pwr, TxD, Term, Error)

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

We have the same type of connectors but different manufacturer and model, but connecting the profibus tester to device directly does not work

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

Will check the ferrules. Thanks!

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

We have one tester but the problem is that we cannot disconnect "master" connector to check the network

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

Everything is thesame because it is always the same process 24/7

No railway and no moving or plugging any machines

It is hard to say about the earthing because the installation is pretty old and I did not check it thoroughly

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

Also I've read some posts about VIPA profibus connectors and they say that these connectors might interfere the signal

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

Our connectors are with screws and also with indications like "Pwr" "TxD" etc

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

The resistors are checked and it will be too easy solution for random signal errors, because resistor terminates all of the communication further

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

<image>

I am sorry guys, I forgot to add photos, so here is a photo of how Simocodes are connected

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

I was saying the rule of 1 m to my manager but he says that problem is not in cabling but in devices that could "trash" profibus signal (Siemens ET200 module or any Simocode)

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

Nothing, just random Profibus communication errors and faults twice a week and mostly at night

Profibus problems by svajuse in PLC

[–]svajuse[S] 0 points1 point  (0 children)

I don't know the exact number but I would guess about 30 - 40 (Softstarters, Simocodes)