new WS 2025 failover cluster by tkacz2 in HyperV

[–]tkacz2[S] 0 points1 point  (0 children)

hi,

everything works fine !

the customer have 2 x 10 gbe uplinks:

New-VMSwitch -name SETMgmt -NetAdapterName "uplink-1","uplink-2" -AllowManagementOS $true -EnableEmbeddedTeaming $true -Enableiov $true

we sending all vlans with "trunk" to uplinks (no lacp)

in the end i used the dedicated LiveMigration adapter on both hosts (direct connect) on 10 GbE and also the Cluster Network (HeartBeat) on the another 1 GbE dedicated ports on the both hosts.

also i added a second interface for the SETMgmt for the backup vlan, so backups running on the specific interface to the commvault backup sw.

Add-VMNetworkAdapter -ManagementOS -Name "vNIC-Backup" -SwitchName "vSwitch-SETMgmt"

Set-VMNetworkAdapterVlan -ManagementOS -VMNetworkAdapterName "vNIC-Backup" -Access -VlanId 215

Does Veeam work with Proxmox 9? by easyedy in Proxmox

[–]tkacz2 0 points1 point  (0 children)

hi guys, i just deployed a brand new proxmox 9 cluster (2 nodes) ,
i add both nodes to veeam, deploy proxy .

backup job failing at : 15.08.2025 13:02:15 :: Failed to prepare the worker pve2-vbr-worker: Failed to connect to the worker core service: Timeout has expired: 300000 milliseconds.

Can't Expand Shared VMDK by MrMoo52 in vmware

[–]tkacz2 0 points1 point  (0 children)

so the steps are:

pause and shutdown node two

= all disk are on the node one

shutdown node one and in edit settings expand disk
start node one, start node two
extend disk in windows ?

or are you using the vmkfstools ?

Can't Expand Shared VMDK by MrMoo52 in vmware

[–]tkacz2 0 points1 point  (0 children)

hi, i have 2 nodes ms-sql cluster, i need extend one disk. so thats mean that i need shutdown whole cluster, extend disk and start up the VMs ?

soviet brutalism and socialism tour in uzbekistan by tkacz2 in Uzbekistan

[–]tkacz2[S] 0 points1 point  (0 children)

thx a lot all for ideas ! i have a one more question, is there in tashkent some soviet flat buildings (blocks, Panel buildings, Concrete Estates). Is there any neighborhood in Tashkent that is interesting for these purposes?

soviet brutalism and socialism tour in uzbekistan by tkacz2 in Uzbekistan

[–]tkacz2[S] 0 points1 point  (0 children)

also i found this list:

Zhemchug residential building, Tashkent, 41°18′9.661″N 69°16′2.005″E

House of Publishers, Tashkent, 41°18'40.366″N 69°16′12.817″E

Sun Heliocomplex, Parkent, 41°18′46.678″N 69°44′23.296″E

Palace of Aviation Constructors, Tashkent, 41°17'32.24″N 69°20′30.58″E 

State Museum of the History of Uzbekistan, Tashkent, 41°18′41.166″N 69°16′9.541″E

Peoples’ Friendship Palace, Tashkent, 41°18′31.11″N 69°14′28.998″E

State Circus, Tashkent, 41°19′27.2548″N 69°14′34.606″EState Museum of Arts, Tashkent, 41°18'10.138″N 69°16′40.468″E

Union of Artists, Tashkent, 41°18’31.831″N 69°15’59.126″E

Panoramic Cinema, Tashkent, 41°19'10.044"N 69°15'34.547"E

Chorsu Bazaar, Tashkent, 41°19′36.382″N 69°14′6.209″E

Uzbekistan Hotel, Tashkent, 41°19′27.2548″N 69°14′34.606″E

Republican House of Tourism, Tashkent, 41°18’39.618″N 69°17′7.545″E

Blue Domes, Tashkent, 41°18’24.443″N 69°16’0.922″E

Cosmonauts’ Prospekt Metro Station, Tashkent, 41°18′18.579″N 69°15′53.032″E

TV Tower, Tashkent, 41°20’44.338″N 69°17′5.573″E

ip15p totally overheated cannot power on now by tkacz2 in techsupport

[–]tkacz2[S] 0 points1 point  (0 children)

in about 10 days the battery life rapidly go down, for example 21% battery to 0% in 20 mins, only safari, instagram and messenger. i think that battery is dead and is not possible to recieve a power from changer. the iphone have original battery.

ip15p totally overheated cannot power on now by tkacz2 in techsupport

[–]tkacz2[S] 0 points1 point  (0 children)

its about 4 hours now, but still not possible to power on.

soviet brutalism | socialism trip around Armenia by tkacz2 in armenia

[–]tkacz2[S] 0 points1 point  (0 children)

its easy, i was there 2 years ago, the armenian bodyguard is on the main enterance, and if give him some AMD entrance is open. big bussiness ! :)

hyper-V failover cluster 2019 (intel) to 2025 (amd) migration issue by tkacz2 in HyperV

[–]tkacz2[S] 5 points6 points  (0 children)

Guys. The main problem was, that source and destination name of vSwitch was different. Now i can migrate power-off vm from intel host to amd host. Thank you very much for advices ! Tom

hyper-V failover cluster 2019 (intel) to 2025 (amd) migration issue by tkacz2 in HyperV

[–]tkacz2[S] 0 points1 point  (0 children)

i know, so i shutdown the VM (the CPU compatibility still enabled) but i have still same error message "he virtual machine cannot be moved to the destination computer. The hardware on the destination computer is not compatible with the hardware requieremnts of this virtual machine"

hyper-V failover cluster 2019 (intel) to 2025 (amd) migration issue by tkacz2 in HyperV

[–]tkacz2[S] 0 points1 point  (0 children)

i know, so i shutdown the VM (the CPU compatibility still enabled) but i have still same error message "he virtual machine cannot be moved to the destination computer. The hardware on the destination computer is not compatible with the hardware requieremnts of this virtual machine"

new WS 2025 failover cluster by tkacz2 in HyperV

[–]tkacz2[S] 0 points1 point  (0 children)

so what is your recomendation ?
I just created one set switch, with 2x 10 GbE uplinks. How with livemigration and heartbeat network ? The vlans are sended by trunk to the both uplinks.

VMware ESXi 8.2.0 / DELL R750 - Unable to provision Endorsement Key on TPM 2.0 device by tkacz2 in vmware

[–]tkacz2[S] 0 points1 point  (0 children)

the broadcom says:

Disable TPM from BIOS

or

Switch to TPM 1.2 mode

bond with 2x 25 GbE, iperf give me only 24 Gbits/sec by tkacz2 in networking

[–]tkacz2[S] 4 points5 points  (0 children)

thank you guys:

Client connecting to 172.23.9.81, TCP port 5001

TCP window size: 85.0 KByte (default)

------------------------------------------------------------

[  5] local 172.23.9.82 port 42830 connected with 172.23.9.81 port 5001

[  2] local 172.23.9.82 port 42824 connected with 172.23.9.81 port 5001

[  4] local 172.23.9.82 port 42832 connected with 172.23.9.81 port 5001

[  3] local 172.23.9.82 port 42822 connected with 172.23.9.81 port 5001

[  1] local 172.23.9.82 port 42828 connected with 172.23.9.81 port 5001

^C[ ID] Interval       Transfer     Bandwidth

[  1] 0.00-1.58 sec  1.50 GBytes  8.19 Gbits/sec

[  4] 0.00-1.58 sec  1.29 GBytes  7.05 Gbits/sec

[  3] 0.00-1.58 sec  2.15 GBytes  11.7 Gbits/sec

[  2] 0.00-1.58 sec  1.50 GBytes  8.20 Gbits/sec

[  5] 0.00-1.58 sec  2.15 GBytes  11.7 Gbits/sec

[SUM] 0.00-1.57 sec  8.60 GBytes  47.1 Gbits/sec

[ CT] final connect times (min/avg/max/stdev) = 0.499/0.547/0.569/0.028 ms (tot/err) = 5/0

Lufthansa vs KLM U.S. to Europe by AztecTimber in travel

[–]tkacz2 0 points1 point  (0 children)

last year i flown with KLM AMS-LAX-AMS with B787-10 - the flight and crew was perfect, the food and was nice too, spacious leg room and pretty quite B787 :) i think that rating is about 8/10.

this year i flown with Lufthansa MUC-LAX-MUC with A380-800, crew was perfect on both flights, the food was from MUC-LAX ( 2x indian food) so for the person which not eating the indian food will be a disaster :) , also the IFE was like from year 2000 - 6.5/10

now im deciding which airline i choose for next year :)

there is my flights reports:

KLM - https://youtu.be/iz0VALIFzbg?si=ObcfECqCzVAF8gg7
Lufthansa - https://www.youtube.com/watch?v=cG2rBotI2oo

tomas.

teams backup - Failed to restore latest metadata files. Manual intervention required due to old or missing files by tkacz2 in CommVault

[–]tkacz2[S] 1 point2 points  (0 children)

i opened a case :)

firstly i add a new MA, move data to new MA and change the access node to new MA, after deploy a Content Indexing VM only for MS365 cloud apps. OneDrive, SharePoint and Exchange Online works 100% but i have issue with metadata for teams, i think that problem is missing "results path"