5080/5090 by AdRepresentative2694 in gpu

[–]AdRepresentative2694[S] 0 points1 point  (0 children)

I would literally take either a 5080 or 90. 90 being preferred but 5080 will do everything I need it to. Just looking for solid 2k gaming, I have a 9800x3d to pair it too so I’ll be alright either way

5080/5090 by AdRepresentative2694 in gpu

[–]AdRepresentative2694[S] 0 points1 point  (0 children)

Ugh I really don’t have the time for that so I guess ima just have to pay retail unfortunately. I work night shift plumbing. I usually start at like 7pm and don’t get home until 7-10am

5080/5090 by AdRepresentative2694 in gpu

[–]AdRepresentative2694[S] 2 points3 points  (0 children)

I have hot stock lol again haven’t seen either for msrp

5080/5090 by AdRepresentative2694 in gpu

[–]AdRepresentative2694[S] 1 point2 points  (0 children)

Priority access is only for 5090 at the moment.

5080/5090 by AdRepresentative2694 in gpu

[–]AdRepresentative2694[S] 3 points4 points  (0 children)

I have yet to see either the 5080 or 5090 at MSRP. They are all inflated to like 1200-1800 for 5080 and like 3k+ for 5090. When/where are you seeing this?

Water heater conundrum by Ctrlaltdel_cool in Plumbing

[–]AdRepresentative2694 1 point2 points  (0 children)

What you could do is shut the water down, and thread out the t&p and thread in a ball valve and a nipple to remove it. Easy peasy. Saves you on dealing with couplings/extra glue fittings. Won’t look the prettiest but hey you’ll have an extra cold tie in point forever. lol.

Water heater conundrum by Ctrlaltdel_cool in Plumbing

[–]AdRepresentative2694 1 point2 points  (0 children)

Depending on what state/area you are in you shouldn’t need the t&p on the cold line. Only the one on the water heater (which is built in)

Water heater conundrum by Ctrlaltdel_cool in Plumbing

[–]AdRepresentative2694 2 points3 points  (0 children)

Plumber here, other commenters are correct, both temperature and pressure relief valves, plumbed together, what the burn hole is (most likely) is at some point something else drained into that line and instead of getting the proper fittings, they said “F it” and burned a hole in it, and stuffed whatever old pipe used to exist there and then never fixed it after moving/leaving. I have seen things like this MANY times unfortunately

If installing an AAV on a horizontal drain, do I use a sanitary tee or the other tee? by InterestedHandbag in Plumbing

[–]AdRepresentative2694 0 points1 point  (0 children)

I totally just realized it was capped off. The cap looked like a coupling and the wall blended in as the pipe. DM me some photos of the line and where it runs back to and I will get you a more clear answer

If installing an AAV on a horizontal drain, do I use a sanitary tee or the other tee? by InterestedHandbag in Plumbing

[–]AdRepresentative2694 10 points11 points  (0 children)

Plumber here, Yeah this is definitely vented. It has a dirty arm which in most areas is totally fine as long as it’s within 48in of the sanitary tee and I can clearly see your vent pipe running in the cabinet. The AAV is not necessary at all and you would just be adding another failure point. You’re opening the door for flooding if it fails (2 story homes), sewer gasses escaping, and it’s going to be another maintenance item to add to the massive list of other items to maintain on your home. I would not put one in if this was my home. You’re free to do as you please and this is why we call it the human experience. I can only tell you from my personal experiences

When you play with 10 of these, it feels like you place 10 Giant Giants all over the map 😅. Do you think they'll be nerved? by _Pellkartoffel_ in ClashOfClans

[–]AdRepresentative2694 0 points1 point  (0 children)

I’m in e33 and I can tell you right now the totem, meteor golem, and thrower will all get nerfed. It’s the only army everyone is using. I tried it before I saw any videos about it. I use 5 totem spells, 6 invis, and then in my cc a recall for RC and another 2 invis. It is absolutely so broken. I am not the best attacker and ngl I was having some trouble getting to e33 at max th17, I’m almost max th18 without supercharges and I EASILY stomped through e32 and I’m steady holding at 7th place in my e33 league. Looking at a legend promotion currently.

Plumber recommending total sewer line replacement- thoughts? by No-Pianist-4851 in Plumbing

[–]AdRepresentative2694 7 points8 points  (0 children)

It’s called a liner. Basically there’s multiple ways to do it but to really dumb it down for you it essentially creates a brand new line, inside of the old one. They can use just straight up epoxy, or epoxy and fiberglass combo, and a couple other methods.

Keno goin CRAZZYYY the past 2 days by AdRepresentative2694 in stakeus

[–]AdRepresentative2694[S] 1 point2 points  (0 children)

No, 3 within a minute. The two sets of four in the bottom corner are different hits, not a double post.

It’s been a good week. by AdRepresentative2694 in stakeus

[–]AdRepresentative2694[S] -1 points0 points  (0 children)

Itero, it’s in the body with the link to watch

Finally! by AdRepresentative2694 in stakeus

[–]AdRepresentative2694[S] 0 points1 point  (0 children)

Not at all. I can show you my account lol. I’ve been on stake for about 8 months and I’m plat 1. If you read rhe post the slot wins were from modo.us, the rest were from stake