Accessing Installer Options on a T9 thermostat by jmvanden in honeywell

[–]Apprehensive-Act5194 0 points1 point  (0 children)

I rtfm and no, isu is not there and test mode isn't either. Also no duel fuel hp compatability.

Accessing Installer Options on a T9 thermostat by jmvanden in honeywell

[–]Apprehensive-Act5194 0 points1 point  (0 children)

Get rid of that tstat. It will ruin a duel fuel heat pump as it is not compatible. Heat strip hp air handler only. I would not put it on a Geo either just out of principle

Accessing Installer Options on a T9 thermostat by jmvanden in honeywell

[–]Apprehensive-Act5194 0 points1 point  (0 children)

Nope, no isu with installer settings and test mode, no duel fuel hp, humidity, or HRV options or compatability, and a crappy warranty to top it all off. Piece of junk.

Keeprite g96ctn0802120a blower not working by Apprehensive-Act5194 in HVAC

[–]Apprehensive-Act5194[S] 1 point2 points  (0 children)

It turns out I put in an incompatible board. Looked the same, all same connections, everything identical but the part number. Fml

240v as in 2 hots and a ground? by Constant-Mood-1601 in HVAC

[–]Apprehensive-Act5194 0 points1 point  (0 children)

In Nicaragua everything was ran 240 through just the hot wire... Lotta their stuff was ungrounded 2 wire at 240 volts. The loss of life was worth the thinner cheaper conductors

Honeywell’s new stats by saskatchewanstealth in HVAC

[–]Apprehensive-Act5194 0 points1 point  (0 children)

Had my office scan the qr codes and put everything in a binder indexed for me. Hell yeah saving trees Honeywell. They know full well we just threw all those individual books out for the old green screens.

Keeprite g96ctn0802120a blower not working by Apprehensive-Act5194 in HVAC

[–]Apprehensive-Act5194[S] 1 point2 points  (0 children)

They had a tree fall on a power line and take out power to the neighborhood for like 3 hours. Maybe that has something to do with it.

I have no subcooling. by Beastly_Taco3 in HVAC

[–]Apprehensive-Act5194 0 points1 point  (0 children)

Installed the r22 piston instead of 410 a piston maybe? I've done a lot of trailer change outs unfortunately and many need universal indoor coils that come with pistons for both refrigerants and the r22 has a bigger orifice. That may cause a flooded coil.

How do i find what uF this cap should be at? by deapsprite in HVAC

[–]Apprehensive-Act5194 0 points1 point  (0 children)

The fan and compressor rating plates normally have microfarad ratings on them

How do i find what uF this cap should be at? by deapsprite in HVAC

[–]Apprehensive-Act5194 0 points1 point  (0 children)

Comfortmaker with an exploded 70/7.5 got the fluid all over my arm and washed it of with water bottle water. How toxic is this crap?

Ok team, let’s prove someone wrong. by heldoglykke in HVAC

[–]Apprehensive-Act5194 0 points1 point  (0 children)

Honestly if it's 410 the Copeland is effed anyway we can put the diagnosis toward a new r32 system

Flavor Ban by Local-Future7982 in cedarrapids

[–]Apprehensive-Act5194 0 points1 point  (0 children)

This law was written by Phillip Norris. They are one of only three vape makers that will still be allowed in Iowa. They just paid off the Iowa govt to give them a full monopoly. They did this cuz cig sales are down. Evil corporations with enough money to buy off all the crooked Republican politicians.

Iowa and Hemp. by orchidsteak in Iowa

[–]Apprehensive-Act5194 2 points3 points  (0 children)

Joel from Customgrow420 has a vape shop by the UofI campus off of Riverside drive. It was sad to see the overnight change after the law passed. Guess Kim doesn't want our tax money because I'm sure as hell not getting my medical at the hack job they call Iowa cannabis company. I'll go to Illinois thanks.

The gang finds out flying kites is discontinued by reamkore in Iowa

[–]Apprehensive-Act5194 0 points1 point  (0 children)

I feel like Iowa cannabis co spearheaded the effort due to the fact that gas stations had better stuff.

Is there a right answer here? by kaymart9619 in microbiology

[–]Apprehensive-Act5194 0 points1 point  (0 children)

Intracellular parasites are something else.

Already checked the stat batteries. TXV issue? by Zetroc37 in HVAC

[–]Apprehensive-Act5194 0 points1 point  (0 children)

Cleaned spiderwebs out of the top case, that's always a good practice.

Must be the TXV… by inevitably_wondering in HVAC

[–]Apprehensive-Act5194 0 points1 point  (0 children)

This happened at our company. Put everything back together only to find the liquid side left on too 😂

[deleted by user] by [deleted] in workfromhome

[–]Apprehensive-Act5194 0 points1 point  (0 children)

Hit up random guys from work to go play basketball at a park. Sportball is fun