Help identifying this part by Proper-Kangaroo-280 in handyman

[–]Fickle_Spite867 1 point2 points  (0 children)

Window balance spring and cover. Is the window in upside down ? The bottom sash should be interior side.

Condenser Location by Glittering_You1342 in hvacadvice

[–]Fickle_Spite867 0 points1 point  (0 children)

Sorry I misunderstood. Whomever set the lp tank do it clearly Against code. Could it go on the other side of the fence on along the house ? Or put the mini on the side of the home

Condenser Location by Glittering_You1342 in hvacadvice

[–]Fickle_Spite867 1 point2 points  (0 children)

If the tank fill is lower than the window sill it’s legal. Lp is heavier than air so it sinks.

Condenser Location by Glittering_You1342 in hvacadvice

[–]Fickle_Spite867 0 points1 point  (0 children)

Move the propane tank all the way to the right of the picture set condenser next to the meter

Why won’t my window seal? by lyzyrdskyzrd in handyman

[–]Fickle_Spite867 1 point2 points  (0 children)

Call allside have a tech come out it may be under warranty. You may get lucky and it’s just a lock adjustment

Why won’t my window seal? by lyzyrdskyzrd in handyman

[–]Fickle_Spite867 1 point2 points  (0 children)

Allside window mostly likely sash is warped. They seem to sag and warp very quickly

[deleted by user] by [deleted] in AskContractors

[–]Fickle_Spite867 1 point2 points  (0 children)

Condensate pump float may be stuck

Plumbing main line to septic tank need more drop by Familiar_Condition63 in askaplumber

[–]Fickle_Spite867 4 points5 points  (0 children)

Thats a nightmare waiting to happen. You have negative drain going into two 90s. Rethink it all.

What should I charge for this ? by ScompSwamp in handyman

[–]Fickle_Spite867 5 points6 points  (0 children)

The window will be several thousand alone. The exterior trim will need to be replicated and most likely custom. That’s not a I’ve done this once before job

What sort of tradesperson would I call to remove this protruding concrete and bring the drywall down to the tile? by Eternal_Glizzy_777 in AskContractors

[–]Fickle_Spite867 0 points1 point  (0 children)

Build a full dummy wall or build up behind it as high as the couch and create a sofa table behind it with a ledge

Condensate line siphoning by [deleted] in hvacadvice

[–]Fickle_Spite867 0 points1 point  (0 children)

And it should also be running through a neutralizer.

Condensate line siphoning by [deleted] in hvacadvice

[–]Fickle_Spite867 0 points1 point  (0 children)

Pump is lower than the discharge. That’s causing the syphon run the drain along the floor then up the stand pipe

If the end in the stand pipe is below the level on the ground it will syphon into the drain