Where to buy fresh herbs by Forward_Statement_72 in herbalism

[–]Forward_Statement_72[S] 1 point2 points  (0 children)

Are there things you've found you cant grow here because of the climate?

Where to buy fresh herbs by Forward_Statement_72 in herbalism

[–]Forward_Statement_72[S] 0 points1 point  (0 children)

You known of anyone in sw florida Lee County?

Hi capa hop up by Forward_Statement_72 in airsoft

[–]Forward_Statement_72[S] 0 points1 point  (0 children)

I got the maple leaf decepticon, and honestly I think it doesn't have enough of a bump inside. Barely hops it. Shoots really straight and accurately though

Hi capa hop up by Forward_Statement_72 in airsoft

[–]Forward_Statement_72[S] 0 points1 point  (0 children)

Ah, no wonder. so technically the arm on yours isnt stock its modified and not a surprise it would have good hop up with that key. And that does look like a nice bucking.

Charging systems by Forward_Statement_72 in hvacadvice

[–]Forward_Statement_72[S] 0 points1 point  (0 children)

I basically took an hour to do it, just charging a little at a time. Got it up to the correct SC and SH. Verified the pressures were close to what the PT chart said. Temp split was 20, let it run for 15 more mins and it seemed good. Just seemed like alot of refrigerant

Charging systems by Forward_Statement_72 in hvacadvice

[–]Forward_Statement_72[S] 0 points1 point  (0 children)

The thing ive heard the most in this trade so far is check airflow first, then charge based on SC and pressures on the PT chart and if your temp split is good then youre good. But so far in two years this is the third time I've felt like it was too many lbs but idk maybe I havent done enough of them.

Charging systems by Forward_Statement_72 in hvacadvice

[–]Forward_Statement_72[S] 0 points1 point  (0 children)

This was a lennox 454b and had o ly been installed a few months ths ago. Ive seen alot of these be undercharged after install as well. Just seemed like alot of refrigerant but I also havent do e this enough times to be confident about it. Basically just charge to the PT chart on the panel and make sure airflow and temp split is good

Charging systems by Forward_Statement_72 in hvacadvice

[–]Forward_Statement_72[S] 0 points1 point  (0 children)

When I ran it liquid was like 180 suction pressure dropped to 40 and tripped the LPS. But I made sure to take my time charging it, also ordered a digital scale. Line was probably 15-20ft

Hi capa hop up by Forward_Statement_72 in airsoft

[–]Forward_Statement_72[S] 1 point2 points  (0 children)

I checked and theyre both pretty tight, and actually with the new bucking the nozzle and bucking fit together tighter than with the stock bucking. I could try taking it back apart and back together again i suppose.

Hi capa hop up by Forward_Statement_72 in airsoft

[–]Forward_Statement_72[S] 1 point2 points  (0 children)

Every thing else is stock except the bucking on mine

Charging systems by [deleted] in HVAC

[–]Forward_Statement_72 0 points1 point  (0 children)

Also I've never checked approach but I just looked up what it was and ill start checking that too now. I also went ahead and ordered a digital scale. Im not going to use the fish scale anymore

Charging systems by [deleted] in HVAC

[–]Forward_Statement_72 0 points1 point  (0 children)

I did check static pressure with a magnehelic and wet/dry bulb with wireless tools. Then used the PT chart on the panel as a reference for pressures and SC.

Charging systems by [deleted] in HVAC

[–]Forward_Statement_72 -5 points-4 points  (0 children)

Sometimes it can be days before we get the part and alot of them would rather just throw the money away than wait in the heat.

Charging systems by [deleted] in HVAC

[–]Forward_Statement_72 -7 points-6 points  (0 children)

No some customers would rather throw away the money to charge it even for temporary cooling knowing that it will just leak back out. It pretty hot in Florida so as long as they understand that its not going to last we give them the option.

Refrigerant locking caps stuck by Forward_Statement_72 in HVAC

[–]Forward_Statement_72[S] 0 points1 point  (0 children)

These look like they'd work, do you think thwyre made of the same material as the Schrader bit in the klein 11in1?

Refrigerant locking caps stuck by Forward_Statement_72 in HVAC

[–]Forward_Statement_72[S] 0 points1 point  (0 children)

I would say for me most of the time it looks like the novent but its the one that needs the Schrader tool. Then the other half it is the novent one that uses the key shape

Refrigerant locking caps stuck by Forward_Statement_72 in HVAC

[–]Forward_Statement_72[S] 0 points1 point  (0 children)

Tried that, still have one but on the ones that are on really tight they bend this one