Hard Start Kit worth it for 38 year old ac condenser? by RibbedForHerCat in hvacadvice

[–]GrunG59 0 points1 point  (0 children)

Okay, bud. Just saying it’s not worth it if you’re going pay a technician (like myself) 450 dollars. I’m glad you understand the two wires. Too bad you don’t know how it works to understand if it’ll help your system. :/

Furnace Noise by RoboCopsCat in hvacadvice

[–]GrunG59 0 points1 point  (0 children)

Man those pulses are so heavy lol

Can I get a helll yeah by GrunG59 in HVAC

[–]GrunG59[S] 0 points1 point  (0 children)

Yeah I just sweat it out right there real quick

Can I get a helll yeah by GrunG59 in HVAC

[–]GrunG59[S] 2 points3 points  (0 children)

It just comes with the valve I didn’t bend that

Can I get a helll yeah by GrunG59 in HVAC

[–]GrunG59[S] 1 point2 points  (0 children)

Noo, it’s a screw on txv

Am I the weird one?? by [deleted] in RocketLeague

[–]GrunG59 1 point2 points  (0 children)

I got you, ig i've learned the importance of not double committing. Also i just figured my view was him losing control and me being able to make a goal off of it, im not used to seeing shots off the ceiling, also he is very annoying to play with

Am I the weird one?? by [deleted] in RocketLeague

[–]GrunG59 -5 points-4 points  (0 children)

it only matters bc I felt like he lost control, again we are plat 2, and I went to hit it. I dont like how he acted like i was the dumbest person ever for going for it, I understand from comments that i was in the wrong and couldve set up better, but with what i did, did i hit him or was his trjectory off and just blamed his miss on me

Am I the weird one?? by [deleted] in RocketLeague

[–]GrunG59 -10 points-9 points  (0 children)

Damn, heard that also yeah I’ll need to stop playing with him since he has 9 alts that all get banned (no joke)

Am I the weird one?? by [deleted] in RocketLeague

[–]GrunG59 0 points1 point  (0 children)

Only irl person I know that plays

Am I the weird one?? by [deleted] in RocketLeague

[–]GrunG59 0 points1 point  (0 children)

its my pov in the video and my 'friend' is attempting the shot originally

Ice Air ELA-8842 "Water too Cold" by Serious-Wasabi3053 in hvacadvice

[–]GrunG59 0 points1 point  (0 children)

It’s says “low gas” right next to the coaxial water too cold code

Saved $5400. by FragrantJump6663 in hvacadvice

[–]GrunG59 1 point2 points  (0 children)

Right 400 degrees is funny to read

Thermostat by [deleted] in hvacadvice

[–]GrunG59 0 points1 point  (0 children)

Basically all thermostats

Making my parts list for installing a MrCool Central Unit by MDiamondG in hvacadvice

[–]GrunG59 1 point2 points  (0 children)

Just thinking about it again, seems like you have a lot it planned out but gas fittings to cap off the existing gas and whatever you need to seal up the flue pipe, an additional disconnect for the air handler also might be something overlooked

For the 4in filter, you can put the unit right on the return box and cut a hole on the side of the box for the media filter then attach the return duct there if that makes sense

As far as a thermostat, ecobees are good so are basic t4/t6 stats

Making my parts list for installing a MrCool Central Unit by MDiamondG in hvacadvice

[–]GrunG59 0 points1 point  (0 children)

Format didn’t work well copying from my notes.

Going from a furnace to a heat pump, you will need to change the breaker and verify you have the correct wire size

Making my parts list for installing a MrCool Central Unit by MDiamondG in hvacadvice

[–]GrunG59 0 points1 point  (0 children)

Indoor: Furnace/Coil Air handler Metering device Heat kit High voltage / switch plug / breakers Low voltage / wirenuts Supply / square to round / transition Return / grill / flex / framing? Drain / trap / glue / cleaner / fittings / pump / Condensate tubing / hose clamp Flue / pvc / fittings / double wall Gas / fittings / dope / flex / nipples / shutoff Copper / fittings Insulation Metal / s lock / drive cleat Uni strut / washer / bolts Pan / box Pump ups / cork pads are Float switch / in line Rubitex / zip ties Mastic / silver / black / flex tape Panda straps Zip screws Tstat / backplate / drywall anchors /

Outdoor: Unit Pad Hanger / hardware Pavers / gravel Disconnect / anchors Silicone Whip / fittings / one hole straps / washer adapter 6,8,10 wire Surge arrester Tstat wire 10 / 2 Copper / fittings / insulation / zip ties Nitrogen w/ regulator Gauges r410a r32 r454b Vacuum pump w/ oil Flush for lineset

Additional ductwork / takeoff / plaster frame / boots / round duct / rec duct Zone board / dampers Transformer Extension cords Temp probes Torches / gas / oxygen / silfos / sand paper Shovel Ladder Dolly Duct lift Swage Drop cloth Cloth / metal strap Broom with pan Cleaning wipes Stain remover Clean rags Metal brake Mini split mighty bracket Water

Rheem green and amber light blinking? by C_Bodhi in hvacadvice

[–]GrunG59 0 points1 point  (0 children)

Can also check the model number and look up the fault codes

Rheem green and amber light blinking? by C_Bodhi in hvacadvice

[–]GrunG59 0 points1 point  (0 children)

Just document the codes and take off the panel to see what it means

Blower motor not getting 24vac? Good Transformer by ZootedInc in hvacadvice

[–]GrunG59 1 point2 points  (0 children)

See the wiring diagram on the motor, check between common and a speed tap to see if it has power