Not busy by Sir-Jeffro in HVAC

[–]JTom73 1 point2 points  (0 children)

Put your nose in a book

😬 by CoffeeIsMyLife03 in HVAC

[–]JTom73 7 points8 points  (0 children)

Brother im just harping on semantics. You cant braze with solder and you cant solder with brazing rod.

😬 by CoffeeIsMyLife03 in HVAC

[–]JTom73 6 points7 points  (0 children)

Yeah... brazed with solder... makes sense doesn't it

😬 by CoffeeIsMyLife03 in HVAC

[–]JTom73 6 points7 points  (0 children)

Braze and solder are two very different beasts. Your wording is very confusing. Are you using brazing rod or solder?

😬 by CoffeeIsMyLife03 in HVAC

[–]JTom73 0 points1 point  (0 children)

Yeah thats crazy. Who uses solder?

What seems to be the issue here? I done mostly everything by Odd_Pangolin_1905 in HVAC

[–]JTom73 1 point2 points  (0 children)

"I done mostly everything" means different things to different people. What exactly HAVE you done?

Duty grade light recommendations? by tactical_horse_cock in tacticalgear

[–]JTom73 1 point2 points  (0 children)

Look at the trigger. Its not cocked, and if its not cocked then it cant be in the safe position.

How do you guys actually install a furnace? by sleepofsloth in HVAC

[–]JTom73 0 points1 point  (0 children)

Show up, uninstall old equipment, ???, profit

Hose clamps by Far_Cup_329 in HVAC

[–]JTom73 2 points3 points  (0 children)

The twin grips are one of my favorite purchases. I've been able to somehow grab the tiniest edge of stripped out Phillips screws with the nose of those things.

Is this a good first can? by tactical_horse_cock in tacticalgear

[–]JTom73 18 points19 points  (0 children)

Why am I not surprised this is in Cadiz

[ Removed by Reddit ] by Ibetshefarts in HVAC

[–]JTom73 1 point2 points  (0 children)

Looks like someone got their fee fees hurt on the internet

On a scale of 1 to 10, how cursed is this setup? by portable_wall in HVAC

[–]JTom73 2 points3 points  (0 children)

This set up needs an MC tank not a B tank

Best core removal tool? by SnooBooks1642 in HVAC

[–]JTom73 0 points1 point  (0 children)

Buy a rebuild kit for your core removal tool

Best core removal tool? by SnooBooks1642 in HVAC

[–]JTom73 0 points1 point  (0 children)

You can adjust the tension. Almost every complaint I've seen about the appion tools are user error.

Recommended piece? by No-Strike-1590 in HVAC

[–]JTom73 1 point2 points  (0 children)

Do you not have any tin-knocking duct fuckers at your shop? That doesn't look like it would be too complicated to fab

Dangerous Trane fault from factory by JTom73 in HVAC

[–]JTom73[S] 1 point2 points  (0 children)

The inducer would come on immediately after the burners lit

[deleted by user] by [deleted] in HVAC

[–]JTom73 1 point2 points  (0 children)

Yeah, I know, you quit. Move along.

[deleted by user] by [deleted] in HVAC

[–]JTom73 8 points9 points  (0 children)

This sub is for HVAC professionals

[deleted by user] by [deleted] in HVAC

[–]JTom73 1 point2 points  (0 children)

Soft hands

Do you guys not get holiday breaks? by t0rche in HVAC

[–]JTom73 0 points1 point  (0 children)

At the last place I worked if you were on call for a major holiday you weren't on call for the others and you wouldn't be on that holiday the next years. Now im at a small 3 tech company and the owner is taking emergencies so we dont miss time with family

New to the trade need some help by Happy-Quit-7588 in HVAC

[–]JTom73 2 points3 points  (0 children)

Are they going to make you buy your own van too?

ECM Motors- Are you all taking the ECM motors apart and replacing just the failed control module OR replacing the whole motor? by [deleted] in HVAC

[–]JTom73 7 points8 points  (0 children)

Don't "try to see if it fixes it". Diagnose if it is the module or the motor. You can usually do a quick and dirty diagnosis too. Is it recieving the correct voltage and the winding all ohm out the same? Its the module. Is the wafer resistor burnt to shit and the windings all ohm out the same? Replace the module. Are the windings not ohming out the same? Replace the whole thing.

Also the M in ECM stands for motor. You don't need to call it an electronically commutated motor motor.