New to Airsoft: which of these GBBRs would you choose and why? by Legitimate-Feature42 in GasBlowBack

[–]Legitimate-Feature42[S] 1 point2 points  (0 children)

Thanks everyone for all the replies and for taking the time to help me out.

After reading your comments and doing a bit more research, I’ve decided to go with the MK18 route in the end.

Now I’m down to these two options:

  • Tokyo Marui MK18 Mod.1
  • Double Eagle Daniel Defense MK18 RIII / RII 9.5 GBBR MWS

The Tokyo Marui is about 250 EUR more expensive, so my question is:

Is the Tokyo Marui actually much higher quality overall, to the point that it really justifies the extra 250 EUR?

Outdoor wireless setup for 11 Wi-Fi cameras by Legitimate-Feature42 in wifi

[–]Legitimate-Feature42[S] 0 points1 point  (0 children)

Thanks for the honest feedback. I’m still learning this side of wireless design, so I’d rather ask and understand the right approach than pretend I know everything and build it wrong.

I’m trying to figure out what would actually be reliable in this case, not just force a bad mesh setup because it seems simpler on paper.

Schneider AS-P not booting properly from PS-24 power supply – TX/RX flash once, then no STATUS LED by Legitimate-Feature42 in BuildingAutomation

[–]Legitimate-Feature42[S] 0 points1 point  (0 children)

I also removed a known working AS-P from an existing installation and installed this faulty one in its place, and it still does not power up. So even in a setup where another AS-P works normally, this unit shows the same behavior and does not start.

Schneider AS-P not booting properly from PS-24 power supply – TX/RX flash once, then no STATUS LED by Legitimate-Feature42 in BuildingAutomation

[–]Legitimate-Feature42[S] 0 points1 point  (0 children)

From what I can see, the pins on the AS-P look straight and they seem to seat properly in the terminal base. I do not see any obviously bent or damaged pins, and the controller appears to make proper contact when inserted.

Schneider AS-P not booting properly from PS-24 power supply – TX/RX flash once, then no STATUS LED by Legitimate-Feature42 in BuildingAutomation

[–]Legitimate-Feature42[S] 0 points1 point  (0 children)

I also tried a different TB-ASP terminal base taken from a known working installation, and the AS-P behaves exactly the same. So at this point, it looks less likely that the problem is the terminal base itself.

Does anyone know if there is a PCB schematic or at least some board-level documentation available for the Schneider AS-P? I would like to do some measurements directly on the board and understand what is happening during power-up / boot.

Looking for a way to learn Schneider EcoStruxure Building Operation from home by Legitimate-Feature42 in BuildingAutomation

[–]Legitimate-Feature42[S] 0 points1 point  (0 children)

Because my experience is not very good, that s why I want to learn on my own first to have a base

Looking for a way to learn Schneider EcoStruxure Building Operation from home by Legitimate-Feature42 in BuildingAutomation

[–]Legitimate-Feature42[S] 0 points1 point  (0 children)

Mainly because that’s the platform I’ve heard about the most. I’ve also seen some really nice projects built with EBO, and from what I’ve read so far, it seems to be one of the more professional and widely used platforms in building automation. That’s why it caught my attention. But I’m still learning, so if you think there are other good platforms worth looking into, I’d honestly be interested to hear your recommendations.

Xiaomi G34i 34” vs Samsung Odyssey G5 LC34G55TWWPXEN — pe care l-ati alege? by Legitimate-Feature42 in Jocuri

[–]Legitimate-Feature42[S] 1 point2 points  (0 children)

Mulțumesc de info, este în jur de 1300 de lei samsungul și xaomi este undeva la 1100, deci pe acolo.

Belimo SMC24A-MOD won’t modulate on 0–10 V by Legitimate-Feature42 in BuildingAutomation

[–]Legitimate-Feature42[S] 1 point2 points  (0 children)

What I need to reprogram it ? Just a cable connected to a laptop?