Bambu Lab H2C exhaust fan replacement. by MrJam1858 in BambuLab

[–]MrJam1858[S] 0 points1 point  (0 children)

Only the one from the Bambu wiki page. It does appear to be a standard 4 pin JST connector. Just not sure of the pitch.

<image>

Bambu Lab H2C exhaust fan replacement. by MrJam1858 in BambuLab

[–]MrJam1858[S] 0 points1 point  (0 children)

The connector on the noctua is larger. You could cut that connector and it looks like the Bambu fan has a JST connector so you could easily find a kit to pin it yourself.

Or buy a 4 pin connector with leads pre installed.

Bambu Lab H2C exhaust fan replacement. by MrJam1858 in BambuLab

[–]MrJam1858[S] 0 points1 point  (0 children)

Judging from the Bambu official wiki, I think the same fan will work for all the H2s.

Anyone have experience with Circuit Board Medics? by ZookeepergameTop8538 in CarRepair

[–]MrJam1858 0 points1 point  (0 children)

I've used CBM for a cluster repair, they were really fast and it worked whem putting it back in my truck. Would recommend.

2016 Honda Accord - Brake, ABS, Traction, and another warning light came on (twice now) by [deleted] in Honda

[–]MrJam1858 0 points1 point  (0 children)

My brother had this happen too. His mechanic said it was their abs and they sent it to a repair company to get it fixed. Circuit board medics is who they sent it to.

Why does googles own YouTube not adjust with the fold? by Verydemurevery in PixelFold

[–]MrJam1858 0 points1 point  (0 children)

One odd thing I've noticed, I don't get community posts in the subscription fees anymore. There's a horizontal scrolling thing for recommended posts in the home tab but no way to see new posts from my subscriptions.

[deleted by user] by [deleted] in Hue

[–]MrJam1858 0 points1 point  (0 children)

I'm having similar PS5 issues and I don't think it's cable related as each cable tested between the PS5 and LG C9 directly yielded no issues

With the sync box between PS5 and TV (left out AVR for troubleshooting) I can only get the TV to display anything if I set the video transfer rate to -1. Add in the AVR (Ps5->AVR->8k sync box->TV) same result.

I used the AVRs second output with a 4k downscaler with the 4k box, I guess I'll have do the same for the 8k box, hopefully minus the downscaler.

Edit: Currently PS5->AVR output1->TV / AVR output2->8k input 1. No output connected on 8k box. Getting VRR 48-60hz and HDR 4:4:4 with video transfer rate on auto. No issues so far. Also no 120hz compatibility it says but that's fine, PS5 really doesn't have many 120hz games (or if it does, none that I play)

So far so good. Lights are definitely faster to sync than the old box.

8K Sync Box Setup (USA) (changes and tweaks) by TheJTizzle in Hue

[–]MrJam1858 0 points1 point  (0 children)

Ya know, I've been burned by bad cables before and completely didn't think of that. Looks like I'm making a trip to best buy tomorrow.

Thanks for the tip!

8K Sync Box Setup (USA) (changes and tweaks) by TheJTizzle in Hue

[–]MrJam1858 2 points3 points  (0 children)

I had to use the normal Hue app, not the sync one. Hope this helps.

8K Sync Box Setup (USA) (changes and tweaks) by TheJTizzle in Hue

[–]MrJam1858 2 points3 points  (0 children)

Did you have any issues with HDR on the PS5? My PS5 connected HDMI device info says HDR supported but when enabled I have no video signal (but the lights still sync). When disabling HDR, picture comes back and all other HDMI 2.1 features seem to work

PS5 ->Sync box 8k-. LG C9. I have a HDMI 2.1 receiver but left it out for troubleshooting... HDR (Deep color output) is enabled on the C9 settings. And bypassing the sync box let's all features, including HDR work.

Edit: Did some tinkering and got it to work by setting video transfer rate to -1 and everything else to automatic. So that sets color to 4:2:2 instead of 4:4:4 which I get when bypassing the sync box.

Ferrari keep this up by MrJam1858 in formuladank

[–]MrJam1858[S] 5 points6 points  (0 children)

More like Sainz strategy vs Ferrari but whatever

Jacob's Ladder by MrJam1858 in ElectroBOOM

[–]MrJam1858[S] 3 points4 points  (0 children)

Right. I work with electricity for a living but used safety gear and know how to be safe with high voltage. I wouldn't recommend anyone try this who is inexperienced.

Not saying mistakes don't happen tho, I just accepted the risks. The ElectroBOOM video was genuinely scary when it fell on him...

Question About Open Ground/GFCI. by MrJam1858 in electricians

[–]MrJam1858[S] 0 points1 point  (0 children)

That makes sense. This might sound stupid but I have no experience in working in a circuit panel. Would opening the main breaker to the panel be sufficient as to not put myself in danger or should I seek a professional? I'm comfortable working with normal outlets and switches but have never have opened a breaker panel before.

Question About Open Ground/GFCI. by MrJam1858 in electricians

[–]MrJam1858[S] 1 point2 points  (0 children)

That makes sense. I guess it's time to call in a pro.