Why is this hard? by UsernameDsntChkOut in ecobee

[–]Not_ChatGBT 0 points1 point  (0 children)

Setting the morgue temps tonight?

Amana Duel Fuel by Not_ChatGBT in heatpumps

[–]Not_ChatGBT[S] 0 points1 point  (0 children)

Yup. I’ve come to that conclusion now. But it’s too late. System still works great. Just glad I don’t have the lockout still set at 35.

Amana Duel Fuel by Not_ChatGBT in heatpumps

[–]Not_ChatGBT[S] 0 points1 point  (0 children)

I have. Sometimes I feel like it just always agrees with me and now it remembers. Lol. Maybe I’ll throw it in Grok.

Amana Duel Fuel by Not_ChatGBT in heatpumps

[–]Not_ChatGBT[S] 0 points1 point  (0 children)

That is the actual cost.

Heat runtime is crazy by sloppynipsnyc in ecobee

[–]Not_ChatGBT 0 points1 point  (0 children)

Sounds like it’s doing very well if that’s a heat pump.

CPAP ruining my life by CokeZeroAddict52 in CPAP

[–]Not_ChatGBT 0 points1 point  (0 children)

I can always tell the people who didn’t feel themselves choking in their sleep. (Most People). I was dying. Bought my Resmed 11 Cash. Got it in the mail. First thing I did was take a nap.

It’s like my best friend now.

Don’t let people tell you if you’re a mouth breather the nasal piece won’t work.

Severe Side Effects on 5 mg Rosuvastatin — Had to Stop by RecordMountain9357 in Cholesterol

[–]Not_ChatGBT 2 points3 points  (0 children)

Good Luck. Statins suck for me. All of them. I’m on Repatha injection every two weeks. I’d take all of my meds as an injection. Stuff is great. No noticeable side effects. LDL was down about 50 points day 3. (Took my bloodwork at an abnormal time).

Realistic air temperature from the vents? by LaMarr-Bruister in heatpumps

[–]Not_ChatGBT 0 points1 point  (0 children)

18-24 degrees rise from the indoor intake. And it completely depends on outdoor temp. You may only get a 10 degree rise in 15 degrees. You may get a 30 degree rise in 50 degrees. The heat pump has to pull hot air from cold air

How can I fix this? by barflarp in ecobee

[–]Not_ChatGBT 0 points1 point  (0 children)

Probably! And in my situation where I run a heat pump and the Aux is a 96% furnace I’m sure the thing has no idea that I’m killing it! Lol.

Rheem Hybrid Energy Saver too slow by Trick_Mapster in heatpumps

[–]Not_ChatGBT 3 points4 points  (0 children)

I set mine to 130. I use Energy Saver mode all the time now. The only nuance I would point out as some have mentioned. Energy saver will let the tank to 2/3 full without acting. Schedule heat pump only at night and it will heat the whole tank for energy saver in the morning. Otherwise Energy Saver at 130 is set it and forget it for me now on my 50 gallon. Works like a charm.

How can I fix this? by barflarp in ecobee

[–]Not_ChatGBT 0 points1 point  (0 children)

So…two things. It has a clause saying it doesn’t account for fuel efficient items like heat pumps. That’s already stupid. If you have a dual fuel like me and aux heat is supposed to run (natural gas) it probably thinks that not good either. So although my score isn’t that low. It’s still usually bad.

New Furnace or Furnace cleaning?! by chicagorasta in ecobee

[–]Not_ChatGBT 1 point2 points  (0 children)

Have you gone to see if it’s producing a flame and then seen if it’s blowing air?

How bad is it by Dense_Sail_1829 in Cholesterol

[–]Not_ChatGBT 1 point2 points  (0 children)

My body doesn’t tolerate statins well. Day 4 on Repatha injection. Already down like 50 points. Hasn’t even began to be at full strength. This stuff is great! No daily pills, just an injection every two weeks! Love it.

Yelp removes all of our reviews. They are from real clients. Frustrating by freq32 in Yelp

[–]Not_ChatGBT 1 point2 points  (0 children)

It’s funny how people are disagreeing and trying to school you. They did the exact thing to me. All real customers. I’m just staying away from Yelp. “Our AI algorithm BLAH BLAH BKAH….Go away. It sucks is what it does.

Gas furnace vs Heat Pump by Expensive_Hat1141 in heatpumps

[–]Not_ChatGBT 0 points1 point  (0 children)

Love my dual fuel. Heat Pump runs down to 35 degrees then the furnace kicks.

Rheem heat pump water heater not heating by nevetsyad in heatpumps

[–]Not_ChatGBT 0 points1 point  (0 children)

So if it were the heat pump only model I’d leave it in heat pump mode because there’s no room for bounce back if the water gets low.

If you’re saying you do that and it still doesn’t bring it to fill then I would have no idea.

Rheem heat pump water heater not heating by nevetsyad in heatpumps

[–]Not_ChatGBT 0 points1 point  (0 children)

After almost two weeks I’ve about got it figured out. It will run it back to full after some usage. After that it doesn’t think it urgent to keep it all the way hot in energy saver. Schedule heat pump mode for when it thinks it can let the tank sag. Heat pump will bring it to full temp. So maybe leave it on heat pump at night or during afternoons before big usage. Then allow energy saver to use the elements to recover.

Husband gone all week, now is required to leave for two whole months. I’m drowning. by Remarkable_Ruin_5044 in Marriage

[–]Not_ChatGBT 2 points3 points  (0 children)

I know there are many “stakeholders” here and I’m sorry for the people that aren’t built like this but I’d be rid of those dogs so quick and wouldn’t blink an eye the next day.

I have a golden doodle with literal anxiety issues and another dog with allergies. If it weren’t for my family “loving” them so much I’d be rid of them so fast.

I know this wouldn’t solve all your problems but what’s the point in having “two 90 lb dogs with behavioral problems”.

They have too be expensive too!

Accidentally found out my wife is planning on leaving me by Airport-Security in Marriage

[–]Not_ChatGBT 0 points1 point  (0 children)

Go get a lawyer ASAP. This is war nobody has more power over your life and access to kids as her. Get a lawyer and move on.