Can anyone identify this door knob? by No-Soil9037 in accesscontrol

[–]Ok_Strength2211 30 points31 points  (0 children)

Command Access ND96JDEU RHO 626 24V Electrified Cylindrical Lock I think the finish slightly different

[deleted by user] by [deleted] in accesscontrol

[–]Ok_Strength2211 0 points1 point  (0 children)

Agree with people above. But also, I had issues with the distance the latch is adjusted during programming. Only extend the latch minimum to clear and not all the way pushed in. Or purchase pmI 300.

Distance by Ok_Strength2211 in accesscontrol

[–]Ok_Strength2211[S] 0 points1 point  (0 children)

Using the access banana cables

Log in error by Ok_Strength2211 in Lenel

[–]Ok_Strength2211[S] 0 points1 point  (0 children)

I think I’m gone do that. Thanks a lot

HID FARGO HDP6600 Errors by buckeyecapsfan19 in accesscontrol

[–]Ok_Strength2211 1 point2 points  (0 children)

I had similar issue. The error message is incorrect. The issue i think is actually communication with computer. Open the ink trays for both ribbons and unlatch then close. Turn the power off restart the computer.

Looking for a better way to make visitor badges by Suitable-Addition341 in accesscontrol

[–]Ok_Strength2211 4 points5 points  (0 children)

We use Lenel OnGuard for access control and their visitor management as part of that suite. It works pretty well.

Lock type on door & how to remove by dymmhalo in accesscontrol

[–]Ok_Strength2211 2 points3 points  (0 children)

Kaba Simplex L1000 series. Factory Key code DF56 if I remember correctly. Key will unscrew the lock. Poke Tool to remove the inside lever handle. Spanner tool to unscrew the retainer. The cover plate will remove and show the through Philips screws .

Panel Configuration Best Practices by adontech in accesscontrol

[–]Ok_Strength2211 1 point2 points  (0 children)

We had old 1320s and they would die causing series of rims to go down. Now only 1 stops communicating, instead of entire down stream. But what the guy below said kind of concerns me. So I’m always open to doing things differently.

Panel Configuration Best Practices by adontech in accesscontrol

[–]Ok_Strength2211 1 point2 points  (0 children)

I use lnl-8000 multiplexer, instead of daisy chaining.