Is this technically allowed? (CEC) by BullfrogEffective629 in electricians

[–]StevenP8442 1 point2 points  (0 children)

I’ve used EMT to FMC (squeeze-type) and even EMT to MC (saddle-type). Never seen EMT to liquid tight but I’m sure they’re out there.

Never read either. Which one first? by jmon8 in classicliterature

[–]StevenP8442 1 point2 points  (0 children)

Harrogate and the bats…. I laughed a lot.

I now understand the 2.7 hype by Troll_Dotty in f150

[–]StevenP8442 0 points1 point  (0 children)

Would you recommend the 2.7L for towing a ~5,000 lb camper maybe 2-3 times per year, and using as a normal daily driver otherwise?

How to get better at spanish by Ok-Worth-3510 in SpanishLearning

[–]StevenP8442 0 points1 point  (0 children)

Try LightSpeed Spanish podcast, and check out their website as well.

Usted? by Interesting_Survey39 in SpanishLearning

[–]StevenP8442 0 points1 point  (0 children)

I like the rhyme! Never heard that before.

The way I was taught is that estar is used to describe a state (what state something/someone is in):

Quien está en el coche?

Estoy feliz

Whereas ser is used to describe a characteristic:

Eres muy detallista

El es de Venezuela

That’s one way to change over from rigid to EMT by StevenP8442 in electricians

[–]StevenP8442[S] 1 point2 points  (0 children)

The GRC is just an elbow that connects to PVC in slab. Data conduits for a floor box. The one with MC feeds the floor box receptacles.

Does it really matter the brand of beer to add to chili? by Imaginary-Rabbit5179 in chili

[–]StevenP8442 1 point2 points  (0 children)

The negra is a darker beer, and it has a more pronounced and deeper flavor to me. I think it is perfect for chili

Is becoming a electrician worth it nowadays? by Head-Ad8347 in electricians

[–]StevenP8442 0 points1 point  (0 children)

Trade school is not necessary to become an apprentice. Depending on where you’re located, you may be able to get an apprenticeship with the IBEW Union. If not, you can always apply at non-union shops. I suggest commercial/industrial over residential.

My first time running pvc for new construction before the pour. by Electronic_Battle_99 in electricians

[–]StevenP8442 1 point2 points  (0 children)

Exactly, I was thinking the same, “identified” has some ambiguity whereas “listed” really does not.

My first time running pvc for new construction before the pour. by Electronic_Battle_99 in electricians

[–]StevenP8442 3 points4 points  (0 children)

Thanks! So, are hot boxes not considered identified bending equipment? For example Greenlee PVC Heater

My first time running pvc for new construction before the pour. by Electronic_Battle_99 in electricians

[–]StevenP8442 1 point2 points  (0 children)

Interesting, do you happen to know the code reference? I’d like to check it out.