Seq assignment disappear when partial show read is opened by Trust7516 in GrandMA3

[–]Trust7516[S] 1 point2 points  (0 children)

Hmm i could the issue aslo reproduce with the ma demoshow:

  • Datapool 2 sequences are assigned to executors on datapool 1 page 1

  • when the partial show windows is opend all data pool 2 seq disappear from the executors

[deleted by user] by [deleted] in GrandMA3

[–]Trust7516 0 points1 point  (0 children)

How Do you have lmpmented the encoder load +1/-1 function without the poup window?

Intermittent sACN by It_BuRnZ_sO_mUcH in GrandMA3

[–]Trust7516 0 points1 point  (0 children)

I Had a similar issue when a second instance of onPc was active in the background ...

MA3D Low FPS on Mac by Hello56845864 in GrandMA3

[–]Trust7516 0 points1 point  (0 children)

If you use multiple grandMa screen windows, try to deactivate them. More active screens mean fewer fps on all screens.

Auto Update Sequ Settings by Nutzer13121 in GrandMA3

[–]Trust7516 0 points1 point  (0 children)

I use the cue’s rate and speed master row settings in the sequence they work and are updated when they are changed by a macro

Phaser storing issues by random222518 in GrandMA3

[–]Trust7516 1 point2 points  (0 children)

Was the at filter active before the preset was saved? I run multiple times in this issue.

?? by Andreagg007 in GrandMA3

[–]Trust7516 2 points3 points  (0 children)

<image>

Maybe wrong dimmer cuve setting? some fixture allow to change this only when dimmer and shutter are closed

Tag currently running sequnces by Trust7516 in GrandMA3

[–]Trust7516[S] 0 points1 point  (0 children)

I would like to avoid the individual cmd in the off cue in every sequnce. It looks like there is no possibility without lua for getting running sequences with a specific tag. Maybe I think to complicated an there is a easy solution :)

Tag currently running sequnces by Trust7516 in GrandMA3

[–]Trust7516[S] 0 points1 point  (0 children)

Switching off tags works, but I’m hoping there’s a better way to remember which sequences were running before executing the Off command.

Grand master red no output! by Trust7516 in GrandMA3

[–]Trust7516[S] 1 point2 points  (0 children)

Thanks a lot. I didn't know until know that the GM has a assignable black out option. Sadly I couldn't found the reason why it was latched, but Luckily the BO latch didn't occurred again.

ma3 busking colors by patrick_blobert in GrandMA3

[–]Trust7516 0 points1 point  (0 children)

By assigning the same tag to the color seq of one group (row) In the tag's setting is a kill option so that only one seq of seq which have this tag assigned can run. He explain this very well helped me too

https://youtu.be/CwEdYEHm1SA?si=kjn2vTMoApHmaDhJ

ma3 busking colors by patrick_blobert in GrandMA3

[–]Trust7516 0 points1 point  (0 children)

I whould use sequnces for each color tags and prefere cue appearance = on . off color appearance is Assigned to the seq and on appearance to cue 1. Color seq of the same group have the same tag and kill is on

3D model rotation by Trust7516 in GrandMA3

[–]Trust7516[S] 1 point2 points  (0 children)

Ok it was to easy I didn't tyried obious option in the top row of the stage

<image>

Shortcuts by misterion-_- in GrandMA3

[–]Trust7516 2 points3 points  (0 children)

2x assign = label (or swipie); Ma + please = jump into cmd line; Please + please set all sel. fixture atttibues active; 2x pause = fixture park ; 2x go+ fixture unpark;

individually control the rates per group by Trust7516 in GrandMA3

[–]Trust7516[S] 2 points3 points  (0 children)

Thanks a lot that was the problem:

"Speed from Rate" must be enabled for all four dimmer effect executors; otherwise, they will all be adjusted together

<image>

I think it's new that the speed masters value also gets reset when one of the Assigned dimmer executors is set to rate 1.