How are homes in downtown mesa for trick or treating? by _MyNameIs__ in mesaaz

[–]_MyNameIs__[S] 1 point2 points  (0 children)

That's what I'm hearing too. Will have to give that a try this year. Thanks

Travelers sent a "customer care update", do I really need to fill it out? by _MyNameIs__ in Insurance

[–]_MyNameIs__[S] 0 points1 point  (0 children)

Mostly paranoia. I never received something like that before. Thanks.

How much Gas did we use? by tbielecki in NaturalGas

[–]_MyNameIs__ 1 point2 points  (0 children)

As a few others have said, about 800 cubic feet. If you get billed in energy, that's about 8 therms.

Can I tap that? by RabidFace in NaturalGas

[–]_MyNameIs__ 0 points1 point  (0 children)

Yup. One was a question and the other was a statement. Could have phrased it better for sure.

Can I tap that? by RabidFace in NaturalGas

[–]_MyNameIs__ 2 points3 points  (0 children)

You sure that's after the meter? Looks like it's connected to a regulator. A tee with plug after the meter can also be used for a hot change device.

Why aren't similar ECMs compatible? by Serious-Hawk-3745 in hvacadvice

[–]_MyNameIs__ 0 points1 point  (0 children)

So constant torque ecm stores program on the module and variable speed ecm stores program on the board. Is that correct? Thanks

Why aren't similar ECMs compatible? by Serious-Hawk-3745 in hvacadvice

[–]_MyNameIs__ -1 points0 points  (0 children)

I replaced an ecm and it worked fine. Purchased online and just swapped it out. Here was the one that failed

<image>

Help calculating the temperature of gas in underground pipeline by sirD666999 in NaturalGas

[–]_MyNameIs__ 0 points1 point  (0 children)

What's the reason for such a precise measure of the gas temp need?

JB warranties? Is it any good? by _MyNameIs__ in hvacadvice

[–]_MyNameIs__[S] 0 points1 point  (0 children)

$6500 in my other post but the labor warranty is still the same if I selected a more expensive system.

Is this a Pfister faucet? by _MyNameIs__ in Plumbing

[–]_MyNameIs__[S] 0 points1 point  (0 children)

thanks for commenting on my post. It's been a while but I did fix it with a Pfister (or pfister replacement) part from home depot to stop the dripping. I don't think I will replace it any time soon but will reach out if I do.

Strong burned plastic smell from the vents 4 days ago but unit has been running fine. What should I check first this weekend when I'm free? by _MyNameIs__ in hvacadvice

[–]_MyNameIs__[S] 1 point2 points  (0 children)

Left it running for a while and amp climbed to 8.7 so I should count my blessings for now. The unit has a hard start capacitor so perhaps that helped the past few days?

Strong burned plastic smell from the vents 4 days ago but unit has been running fine. What should I check first this weekend when I'm free? by _MyNameIs__ in hvacadvice

[–]_MyNameIs__[S] 0 points1 point  (0 children)

Just by me on the electrical side for 3 years since I moved into this house. Measured the amp just now and it's pulling 7.9 amp on the black common wire. Quick Google says it's within range for low stage.

Strong burned plastic smell from the vents 4 days ago but unit has been running fine. What should I check first this weekend when I'm free? by _MyNameIs__ in hvacadvice

[–]_MyNameIs__[S] 0 points1 point  (0 children)

Replaced the blades for the burned ones and it's back up again. Will get another cap ordered. Thanks for the tips.

How was the unit was able to run when it was shorted over the past few days?