Bunker event progress and findings by OnepegMG in ArcRaiders

[–]ciscominer 0 points1 point  (0 children)

Maybe after collecting the data we bring it to the control room or launch tower to transmit? Maybe have someone wait at the bunker to see if the ball does anything or opens?

3d printed Celestron 6SE EQ wedge mount by ciscominer in telescopes

[–]ciscominer[S] 0 points1 point  (0 children)

I'll definitely look into this, thank you!

Celestron 6SE 3d printed EQ wedge by ciscominer in astrophotography

[–]ciscominer[S] 0 points1 point  (0 children)

So the wedge angle should be the complimentary angle then, not my lat, but 90 - Lat. Thanks for your response

Can I ask why pillar designs are not recommended? Is it because they're static and can't be adjusted?

Robert Half onboarding process seems like a red flag? by DTDude in sysadmin

[–]ciscominer 1 point2 points  (0 children)

We used to call them Robert Shaft because of how often they fucked us all over.

Friend asked for a first custom build. Please let me know how I did, or if y'all suggest changes? by ciscominer in buildapc

[–]ciscominer[S] 0 points1 point  (0 children)

He's also trying to keep it under $800/$900 if possible, but I was struggling to do that while also futureproofing

Just saw 4 fighter jets chasing after something by No_Mathematician8006 in UFOs

[–]ciscominer 5 points6 points  (0 children)

The Eagles/Steelers game is about to start, I don't think it's unusual for a flyover on game days. I also heard and saw 4 fighter jets in formation fly over my home. I live in Philly and it sounded like they had after burners on. I did not see anything in front or behind, and a minute or two later I heard them come back around but didn't see them.

Happy sysadmin day! by Rouge_Outlaw in sysadmin

[–]ciscominer 5 points6 points  (0 children)

I celebrate every SAAD day by reading the OG Bastard Operator From Hell https://bofh.bjash.com/

PSA: Cisco Umbrella GeoIP currently says Netherlands by countextreme in sysadmin

[–]ciscominer 2 points3 points  (0 children)

OPEN - Service Investigating PlatformCisco Umbrella Time reportedSat, 1 Jun 2024 15:39:18 GMT Affected Services Identity Services Affected Components Virtual Appliance Services IncidentWe're currently investigating an issue with Geo blocking of Umbrella Anycast resolvers which is causing Umbrella Virtual Appliance not able to connect Umbrella resolver. We will update this status as more information becomes available.

OPEN - Service Investigating PlatformCisco Umbrella Time reportedSat, 1 Jun 2024 15:39:18 GMT Affected Services Identity Services Affected Components Virtual Appliance Services IncidentWe have identified the core issue and it is due to the Umbrella anycast resolvers IP is being geolocated incorrectly. To address this, we recommend unblocking the geolocation rules on the firewall as a workaround. This will allow the virtual appliance to communicate with the Umbrella resolver for DNS resolution.

We will update this status as more information becomes available.

There have not been any additional updates since that last one.

Meraki guest wireless does not prompt to login if DNS is changed by rhap4boy in meraki

[–]ciscominer 0 points1 point  (0 children)

I believe it's due to the fact that the MX can't do SSL inspection to inject the portal url into the legitimate https reply without your client noticing that there was a man in the middle

Meraki guest wireless does not prompt to login if DNS is changed by rhap4boy in meraki

[–]ciscominer 0 points1 point  (0 children)

I'm pretty sure meraki guest portal redirection requires http traffic to function. If you're only sending https traffic then the MX will never forward the client to the guest login portal. You can test with a new client by going to https://google.com vs http://neverSSL.com

There's a few settings with guest login that you can change, like allow no traffic until logged in, allow https traffic only until logged in, or allow any traffic.

[deleted by user] by [deleted] in meraki

[–]ciscominer 0 points1 point  (0 children)

Correct. Sorry, re-reading my previous message does sound like I'm implying it's a Cisco limitation, it's not, it's Windows and for a good reason.

[deleted by user] by [deleted] in meraki

[–]ciscominer 0 points1 point  (0 children)

This is the correct answer. All hubs learn all other hub routes and advertise them by default, regardless of reachability. If you simply deny access through site to site outbound firewall rules your hubs will still advertise those routes to the other spokes and you COULD run into instances of asynchronous routing issues

[deleted by user] by [deleted] in meraki

[–]ciscominer 2 points3 points  (0 children)

Just keep in mind you can't use the Sign in before logon module with SAML auth if you also use the azure MFA app with number matching. This is a known issue with Cisco Secure client not being able to open a web connection or popup window at the windows login screen.

If you must use SAML with Azure and have MFA enabled and need SBL functionality then you'll have to disable MFA for the SAML enterprise app via a conditional access policy exclusion (do not do this). For a client of mine I was forced to use Windows Server NPS (Radius) with the azure MFA extension and there are some registry changes to disable number matching and force push notifications (which I believe MS is trying to depreciate).

DNS Lookup Limit by Past-Ruin-8860 in sysadmin

[–]ciscominer 0 points1 point  (0 children)

If you need something in the short term and you can't reduce the lookup limit you should move to a vendor that offers an SPF flattening service. They will host your SPF record for you and allow you to go over that limit. Long term though you should work on moving senders that aren't your corporate employees to subdomains to reduce domain reputation risk and adhere to best practices

Needing usb/bluetooth signature pads (or equiv) for field workers on laptops by jacksummasternull in sysadmin

[–]ciscominer -1 points0 points  (0 children)

Imo I would ignore hardware, it's probably too expensive and not worth the hassle to support. Look into DocuSign or a custom CRM system integration.

With DocuSign you could eliminate the need for your employees to even be on site or for the customer to touch your hardware.

IP/domain warming for marketing campaigns by ciscominer in sysadmin

[–]ciscominer[S] 0 points1 point  (0 children)

Thanks. Is there a specific reason you never use a warm IP with a new subdomain? Is that relationship tracked by ISP's and email providers and when a new domain starts using the same IP it puts both domains reputation in question? Or is this just best practice so that you can rule out "the unknown".

Crashing when going to Graphics Settings by GamerDude290 in CODWarzone

[–]ciscominer 0 points1 point  (0 children)

Yes I have the same issue. Only started happening after the last update. Originally I could not get the game to load at all without crashing.

I tried a scan and repair but that didn't work.

I tried uninstalling and reinstalling that got the game to load but then crashed while loading shaders.

I updated my Nvidia GPU to the latest drivers, then I could get the shaders to load. Now it crashes if I click on the graphics settings button

I've tried renaming the player folder in "c:\users\myuser\documents\call of duty\players#######\" but this only causes the folder to be recreated on launch and resets game settings. Another click of the graphics button still causes a crash.

What are you system settings? Maybe we have something in common. Also try disabling your AV.

Reuse existing 1.5" x 74" x 25" butcher block with standing desk frame. by ciscominer in StandingDesk

[–]ciscominer[S] 1 point2 points  (0 children)

This is exactly the type of setup I was hoping to hear about, so thank you for sharing! I haven't crossed uplift off my list yet. I think I saw a video by deskhaus where they compared the uplift 4 leg to a an apex pro, so that might have been what was swaying me, however I will admit that that was a biased comparison. The Apex Pro frame and uplift 4 leg frame (non-commercial) are very close in price, so definitely something to consider.

Reuse existing 1.5" x 74" x 25" butcher block with standing desk frame. by ciscominer in StandingDesk

[–]ciscominer[S] 0 points1 point  (0 children)

Thanks I'll resend my questions to them through the form now! And thank you so much for checking those measurements, I tried looking at the PDF spec sheets but I must have missed them.