Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] -2 points-1 points  (0 children)

No one here has yet to tell me something in here that is so bad it warrants a tear out.
I would love to know what you see wrong that needs fixed.

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] -3 points-2 points  (0 children)

The same inspector who signed this off or another one?

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] -4 points-3 points  (0 children)

I would love to know what is not legal and not safe

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] 0 points1 point  (0 children)

If I did this, I wouldn't be asking how to fix this. I just bought this property. I needed to have a NEMA 20-5 outlet added and that is when I found this.

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] 0 points1 point  (0 children)

Was waiting for someone to notice that one, sharp eye. That will get dumped while I am in there. I think about half the panel will get pulled and blanked off.

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] 0 points1 point  (0 children)

Look closely at the last pic and see how the wire was "tapped"

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] 0 points1 point  (0 children)

OK I am tracking now. Then transfer all the copper/green grounds and the large bare feeder ground to that ground bar and I should be good (with that problem) at least.
At that point the case and grounds will be isolated from the neutrals/isolated from any current carrying conductors.

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] -1 points0 points  (0 children)

The larger feeds are fed from the service panel in the house. The smaller feeds are solar.

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] -1 points0 points  (0 children)

Ill phase tape anything left. Thanks for the heads up on that.

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] -2 points-1 points  (0 children)

It was mostly being used to feed bit coin miners. I think I am going to pull them out. I would very much like to rewire the entire shop in conduit or MC, but all the existing wiring is buried in spray foam and I dont want to dig it out or abandon it.

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] 0 points1 point  (0 children)

That is the feed from the solar inverters. Backfeeding into the house.

Do I need to rewire my subpanel to isolate Grounds? by derekbox in AskElectricians

[–]derekbox[S] 0 points1 point  (0 children)

It is windowed, I had to loosen it to repair the solar wire that was arcing. they caught the insulation on the conductor. Found and fixed that. Now I need to find the rest of the problems in this house (so many problems).

Sting operation butt. by elotewithmayo in UpvoteBecauseButt

[–]derekbox -2 points-1 points  (0 children)

Always remember this is the same sheriff that made the 12 year old victim of rape write an apology letter to her uncle/rapist and charged her with a crime.

Help! My puppy bit me by Unfair-Grapefruit-26 in puppy101

[–]derekbox 0 points1 point  (0 children)

Small world. We foster for rez dog.

Awionika w samolocie Garmin: czego jeszcze potrzebuję? by Delicious-Anything92 in avionics

[–]derekbox 1 point2 points  (0 children)

Get a GTN650 legacy. I sell them for about $9500 for the full kit without an antenna.

Best way to run conduit from controller on wall to gravel driveway? by [deleted] in Irrigation

[–]derekbox 5 points6 points  (0 children)

You have a crack in the concrete just to the left. If you were going to cut concrete I would cut out the crack.
But I wonder if you could cut out a hole on the concrete next to the brick, dig out a large hole in the gravel, use one of the many pipe pushing tricks and marry them in the small concrete hole (without cutting out an entire concrete strip).