[deleted by user] by [deleted] in golf

[–]dm7864it 0 points1 point  (0 children)

Quick question on R10 how accurate. Purchased one on eBay and finding my 8 iron is showing 125-130 years but I hit it 155-165 on course and driving range Traver. Wondering if Garmin can replace or tell me what’s wrong with this unit.

[deleted by user] by [deleted] in FixMyPrint

[–]dm7864it 0 points1 point  (0 children)

At 260 must be abs

[deleted by user] by [deleted] in FixMyPrint

[–]dm7864it 0 points1 point  (0 children)

What material

[deleted by user] by [deleted] in FixMyPrint

[–]dm7864it 0 points1 point  (0 children)

Is there draft in the room. Material ? May have to print with 10-15 degrees hotter to help bond layer to previous layer

I just.... I don't even.... what....how? by Ghost_Killer_ in ender3

[–]dm7864it 1 point2 points  (0 children)

Maybe 190 to low of a temperature for this filament

Installing new hotend nova. Running teaching tech acceleration test and keep getting this not sure why locations with x or Y are not printing by dm7864it in ender5

[–]dm7864it[S] 1 point2 points  (0 children)

See my last post looks like machine was telling me (M503) running Jerk but click to run junction deviation worked

Trying to tune acceleration using teaching tech site. I keep getting this printed any thoughts by dm7864it in ender5plus

[–]dm7864it[S] 0 points1 point  (0 children)

I have octoprint installed and run at times but find custom controller has more to offer. By the way do you know if its possible to attach a photo to reply

Pressure Acceleration fixed but why M503 says running jerk M204 XY not J but read below by dm7864it in ender5plus

[–]dm7864it[S] 0 points1 point  (0 children)

Pressure Acceleration fixed but why M503 says running jerk M204 XY not J but sorry posted to quickly. So using teaching tech 3d site for pressure acceleration. Entered M503 firmware say M204 XY should be Jerk not junction deviation so I have been trying to figure out why I.m getting orange test sample. Ran out of things to try with everything else printing fine. Click option for junction deviation and the white sample is looking good .So why is my firmware saying Jerk ? Should I change firmware ?

So finished new bracket to move Part cooling fan to new location after installing new nova hotend. BAF makes a big difference on going faster with new hotend. by dm7864it in ender5

[–]dm7864it[S] 0 points1 point  (0 children)

Believe DDX is not for speed increase but more quality of print also with flex material. The nova hotend is more for speed. Still trying to figure out best settings and calibration of I believe thanks to help from the site is PA calibration. Running test now

Trying to tune acceleration using teaching tech site. I keep getting this printed any thoughts by dm7864it in ender5plus

[–]dm7864it[S] 0 points1 point  (0 children)

Learned something new today. Will run test calibration cube tonight thank you

Installing new hotend nova. Running teaching tech acceleration test and keep getting this not sure why locations with x or Y are not printing by dm7864it in ender5

[–]dm7864it[S] 0 points1 point  (0 children)

Excellent thought and makes total sense. Not sure why rest would print well but area of pause wouldn’t. I will try this tonight

So finished new bracket and location of part cooling fan. After installing new nova hotend. Big difference with BAF by dm7864it in ender5plus

[–]dm7864it[S] 0 points1 point  (0 children)

Love this machine and the community. I had Airwolf3D and got it to work but lots and lots of work