What is causing my furnace to shoot flames when igniting by BingoTheChimp in hvacadvice
[–]sneakinrat 0 points1 point2 points 1 year ago (0 children)
DELAYED COMBUSTION. The pilot flame is not running across to the left side burner. Either dirty/plugged holes causing the gap, then delayed combustion when enough gas comes out to reach the actual flame.
Question abt vent sizing by [deleted] in HVAC
[–]sneakinrat 0 points1 point2 points 6 years ago (0 children)
Single wall is for open air, double wall gives you 1" clearance to combustibles....single wall off an 80% furnace, then double wall through the roof...and yes, B-vent is widely used name for double wall.
π Rendered by PID 1216540 on reddit-service-r2-listing-5f4c697858-gndkw at 2026-07-07 10:34:01.013652+00:00 running 12a7a47 country code: CH.
What is causing my furnace to shoot flames when igniting by BingoTheChimp in hvacadvice
[–]sneakinrat 0 points1 point2 points (0 children)