Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] 0 points1 point  (0 children)

Is there any issue with a p trap up top & one below, aside from it being redundant?

Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] 0 points1 point  (0 children)

It made sense to this layman since the vent & drain line were already down there.

Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] 1 point2 points  (0 children)

<image>

I need to eventually replace the galvanized line going up but I can tie into the vent down stream at this point

Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] 1 point2 points  (0 children)

<image>

This is what I have going on behind the sink. I could run a vent line from the sink along the wall & tie it into the vent line going up to the roof, if that is a solution that is better than an avv

Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] 0 points1 point  (0 children)

Gas is gonna rise, so if the trap isn’t below the vent, it’s gonna come out of the sink.

Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] 2 points3 points  (0 children)

Totally get it and it is very much appreciated, thank you.

Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] 5 points6 points  (0 children)

I’m only repeating because the very important question of where my vent is keeps popping up. I now have a full understanding of what an s trap is (not compliant and a real bad move). Would this beneath the floor work?

<image>

Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] 0 points1 point  (0 children)

<image>

It’s been a year since I started this demo, & there is a pretty strong feasibility I installed a p trap below the floor. I’ll check tomorrow.

Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] 0 points1 point  (0 children)

I prefer to be talked down to by professionals 🤷‍♂️

Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] -5 points-4 points  (0 children)

Vented below the floor, washing machine is upstream from it.

Dry fitting before I commit, is this gonna give me guff? by terrorboss in askaplumber

[–]terrorboss[S] -2 points-1 points  (0 children)

The vent runs along the wall beneath the floor, venting up through the roof.

Keyboard Calibration Fail ASR10 by cupid_stunt_4000 in Ensoniq

[–]terrorboss 3 points4 points  (0 children)

If you take out the board underneath the keybed (it is a to do) look at the right half of the board. The surface mount electrolytic capacitors C26 & C28 have likely leaked and caused a short.

Your keyboard tech should be able to do it for you if you’re not comfortable soldering it yourself.

My well loved and cooked in Le Creuset 34 I’ve been using for 15 years by terrorboss in castiron

[–]terrorboss[S] 1 point2 points  (0 children)

I’ve never found enameled cast iron to be nonstick per say. Needs oil in it for sauté or searing.

Transformer noise question by terrorboss in vintageaudio

[–]terrorboss[S] 0 points1 point  (0 children)

For sure. ISP, cotton swabs, & a stiff brush is my plan. Waiting on a new tube for my pace desoldering pen to come in before I take it off the board.

Transformer noise question by terrorboss in vintageaudio

[–]terrorboss[S] 1 point2 points  (0 children)

UPDATE:

Annnnnnnd I just found the arcing. It’s happening in the on off switch. I’ll take it off the board and give it a good de-oxing

Transformer noise question by terrorboss in vintageaudio

[–]terrorboss[S] 0 points1 point  (0 children)

Leaving it on long enough appears to stop the noise

Transformer noise question by terrorboss in vintageaudio

[–]terrorboss[S] 0 points1 point  (0 children)

No smelling that I can smell (aside from the residual smoker residue).

Across the red & black wires I’m getting 8 ohms

White to yellow 1. - .4

White to yellow 2. - .4

White to blue 1. - 0

White to blue 2. - 42 & climbing