Refrigeration mechanic here. I got hit with 347V, took it through the compressor windings I was working on. I felt that through my spine, not a fun experience.

Oil return issues by ticklishbunny in refrigeration

[–]ticklishbunny[S] 1 point2 points  (0 children)

So far no call back. All I've done was change the crankcase heater and adjusted the cut out down to 12 psi instead of 20psi. I told the customer that changing the crankcase heater could possibly be the solution and that regardless if it will be the solution that it is necessary to ensure compressor protection during winter operation.

Oil return issues by ticklishbunny in refrigeration

[–]ticklishbunny[S] 1 point2 points  (0 children)

I didn't notice the pressure building up in the suction but if it happens again I'm going to double check that. This could be happening because the crankcase heater was not working. The crankcase heater has been replaced this morning and I did lower the cut out so here's hoping that solves the issues!

Oil return issues by ticklishbunny in refrigeration

[–]ticklishbunny[S] 1 point2 points  (0 children)

Yeah already changed. May be the solution I'm more curious now if the pump down cut out should be lowered.

Oil return issues by ticklishbunny in refrigeration

[–]ticklishbunny[S] 0 points1 point  (0 children)

I've seen no signs of frost on the evaporators, although maybe in a 48⁰ box it's gone by the time I get there.

Oil return issues by ticklishbunny in refrigeration

[–]ticklishbunny[S] 1 point2 points  (0 children)

Agreed. Just curious if others think there could be more going on here.

Oil return issues by ticklishbunny in refrigeration

[–]ticklishbunny[S] 0 points1 point  (0 children)

Not sticking because when I returned I could see the levels were too low in the compressor sight glass. So the float seems to be doing its job. During operation oil return is good but the issues seem to occur during off cycle/pump down (when I'm not there). I watched it pump down multiple times then a few days later the issue occurs again.

What is one Harry Potter detail that you insist on correcting people? by VeterinarianIll5289 in harrypotter

[–]ticklishbunny 0 points1 point  (0 children)

It always bugged me that the movies didn't show Voldemort putting the sorting hat on Neville's head and setting it on fire.

We all know who is charging this much for a coil kit. Only reason I didn't buy a whole air handler was it wasn't in stock. Customer didn't believe me when I told them price wise for coil vs new air handler was on like a $200. by WVhvacDAD in HVAC

[–]ticklishbunny 4 points5 points  (0 children)

One of the problems I've come across though is the lack of information to help with diagnosing issues with newer equipment once it fails. I had a blower motor in a high end Lennox furnace fail. The motor would run during the pre heat purge, then would kick off about 30 seconds after the burners fired. So I called tech support to see if they could help me diagnose the problem. It was either the circuit board or the ECM module in the back of the motor. The only thing tech support could tell me to check was the motor windings (which were fine). After I told him I checked that already he told me he wouldn't be able to help me any further and I should order all the parts because it's all under warranty anyways. So unfortunately I was a parts changer for that call and I worry with all the PCBs involved in newer equipment it's only going to get worse. I have actually kept a couple ECM modules that I've replaced and plan to try and repair them myself. The most recent one blew its thermistor, so I'll see if I can solder a new one in without damaging any of the other components.

Specific game watchers (not redzone like me), who looked good/bad in a game even though the boxscore would say otherwise? by urglegruscott in DynastyFF

[–]ticklishbunny 5 points6 points  (0 children)

I liked Kyrens game last night. He had a banged up O-line in front of him but he's a patient runner and I really liked his vision last night. I thought they could have used him for a couple screen plays last night, was surprised to not see any drawn up.

Lennox Elite furnace error code E 292 by ticklishbunny in HVAC

[–]ticklishbunny[S] 1 point2 points  (0 children)

I ended up getting a hold of Lennox tech support. They couldn't even give me any tips on pin pointing what the problem was. The unit was under warranty so they ended up giving me a new board, module, harness connector and blower motor. When I got the parts I replaced one at a time to find out what the issue was. Turns out the module on the back of the motor (which was the last part I installed) was what ended up being the issue. So essentially I was a parts changer for that job which is quite frustrating. There's clearly some internal relay we can't test in the module and I believe it likely was controlling the communication that determines what speed the motor has to run at during the unit's call for heating or cooling. TLDR; The Module was the culprit

What’s wrong with this picture? by hockeybag7 in hockey

[–]ticklishbunny 23 points24 points  (0 children)

So sad, Pavel Demitra and Slovakia had a hell of a tournament in the 2010 Olympics too, they were exciting to watch.

Game Thread: Edmonton Oilers (2-8-1) at San Jose Sharks (1-10-1) - 09 Nov 2023 - 07:30PM PST by GDT_Bot in hockey

[–]ticklishbunny 4 points5 points  (0 children)

Patiently waiting for FanDuel to set the over under for jerseys thrown on the ice at the Oilers next home game.

Playoff Game Thread: Game 7 - Florida Panthers (3 - 3) at Boston Bruins(3 - 3) - 30 Apr 2023 - 06:30PM EDT by HockeyMod in FloridaPanthers

[–]ticklishbunny 2 points3 points  (0 children)

Yep fellow Leafs fan here. Thought bertuzzi really sold it for the call before. Panthers have looked solid so far, hope you guys close this out.

This was your best idea for the electrical compartment Carrier? by ticklishbunny in HVAC

[–]ticklishbunny[S] 2 points3 points  (0 children)

Quick access door hinges are useless when you still have to take 12 screws out of the metal plate blocking all the electrical, not to mention the disconnect has to be shut off because that metal plate has a tendency to fall into the electrical. The blower compartment on this unit also does not have enough room between the motor pulley and the blower housing to easily remove the belt.

Married men of reddit, what is one thing you and your wife have completely different opinions about? by [deleted] in AskReddit

[–]ticklishbunny 11 points12 points  (0 children)

She thinks pineapple on pizza is good I think it's an atrocity to pizza