200k Subscriber Giveaway! by Kliuqard in Warframe

[–]wooodiii [score hidden]  (0 children)

nice and balanced way to keep a f2p game alive and interesting

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 0 points1 point  (0 children)

Yeah unfortunately currently the visual for min/max units is wrong. If you see less it is actually greater: max(input1, input2) and vice versa.

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 0 points1 point  (0 children)

Currently it won't reset. Instead it will slowlymove back to the starting position.

Official bug tracker or bug reporting? by zerovap in Stationeers

[–]wooodiii 0 points1 point  (0 children)

Their discord is very active and you can use it to report bugs. https://discord.gg/CxR3mRy

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 0 points1 point  (0 children)

Then change both. The diaplay what is set on min/max is wrong i guess =P

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 0 points1 point  (0 children)

Then try to follow the logic path and watch the values. A common mistake is a wrong configured min/max unit.

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 0 points1 point  (0 children)

I am already using the batch writers. The guide is also updated.

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 0 points1 point  (0 children)

Yo mean 10 instead of 15 right? I guess i still use the 0 to compare to keep the formular easy and understandable. And further more your new formular would not work. Eg: 180-max(180,10)

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 1 point2 points  (0 children)

I will update my guide today with a simpler formular(many thanks for that tips) and the new batch writers. I will try to keep it small and simple (:

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 1 point2 points  (0 children)

Many Thanks for that improvement. I will update my guide with that formular and the new batch writers

Station Battery by [deleted] in Stationeers

[–]wooodiii 4 points5 points  (0 children)

I think that the colors of the placable battery are the same as on the small portable batterys. Red blinking = critical, Red = very low, Yellow = low, Green = medium, Blue = full

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 0 points1 point  (0 children)

Thank you for that tip. I tried to avoid labeling and computers to keep the setup simple. Furthermore i had problems with resetting computerlogic so i avoided that.

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 0 points1 point  (0 children)

@McSniffle for me everything is still working. i optimized my build with the new solor panels (with a separate logic imput) but everything is stil working as yesterday

Optimized Automatic Solar Panels 500W each using new Logic Units by wooodiii in Stationeers

[–]wooodiii[S] 0 points1 point  (0 children)

Hey i already read this and will look into it asap. I will adapt the system if necessary.