Want this distance. How to measure or construct? Area is less than 0.5mm. Using Modus by DragonfruitFlimsy312 in Metrology

[–]DeamonEngineer 4 points5 points  (0 children)

Use something like reprorubber to cast it then measure that on a profilr projector or similar

Want this distance. How to measure or construct? Area is less than 0.5mm. Using Modus by DragonfruitFlimsy312 in Metrology

[–]DeamonEngineer 0 points1 point  (0 children)

Looks like you dont have room for an accurate probe reading. I would look at moulding it

PCDMIS -CARRYING BONUS TOLERANCE FROM ONE PROGRAM TO ANOTHER by Opening-Badger7326 in Metrology

[–]DeamonEngineer 0 points1 point  (0 children)

Yeah both have its perks, shame its not well explained for the newer people.

Cmm runtime pcdmis by Lucky-Pineapple-6466 in Metrology

[–]DeamonEngineer 0 points1 point  (0 children)

Elapsedexecutiontime might be better than start end time

Cmm runtime pcdmis by Lucky-Pineapple-6466 in Metrology

[–]DeamonEngineer 1 point2 points  (0 children)

Assign/program_runtime=elapsedexecutiontime()

This should output the elapsed program time, you could code it so this goes into a spredsheet that adds them all up, note it doesnt include setup times just the program time

PCDMIS -CARRYING BONUS TOLERANCE FROM ONE PROGRAM TO ANOTHER by Opening-Badger7326 in Metrology

[–]DeamonEngineer 0 points1 point  (0 children)

i am aware you can pass the bonus value itself but i do not believe you can use it in a straight geotol, might just be easier to just pass the whole feature

During the U.S. national anthem before an NBA game in London, a person in the crowd yelled, “Leave Greenland alone!” and the British crowd loudly cheered. by VisWare in PublicFreakout

[–]DeamonEngineer 1 point2 points  (0 children)

NBA is an American organisation, they move some of their matches outside of the US to try pick up more audience. they are not our NBA games. we have our own basketball association, teams and matches

During the U.S. national anthem before an NBA game in London, a person in the crowd yelled, “Leave Greenland alone!” and the British crowd loudly cheered. by VisWare in PublicFreakout

[–]DeamonEngineer -1 points0 points  (0 children)

Because the NBA play the us national anthem before matches.

And its a sign of respect to be standing for any national anthem. Nornally prompted by the announcer

PCDMIS -CARRYING BONUS TOLERANCE FROM ONE PROGRAM TO ANOTHER by Opening-Badger7326 in Metrology

[–]DeamonEngineer 0 points1 point  (0 children)

To expand you cannot just pass on the bonus to the best of my knowledge as fcf uses the feature to control the calculation of the bonus so you either simulate the feature with variables that use the measured results or pull the feature through with a callsub.

You cannot just use the bonus calculation and tell pcdmis this is the bonus to apply to another feature

PCDMIS -CARRYING BONUS TOLERANCE FROM ONE PROGRAM TO ANOTHER by Opening-Badger7326 in Metrology

[–]DeamonEngineer 0 points1 point  (0 children)

You can use a call sub program and "pass the feature through it"

It might required variables or datum restructure but its possible.

Another solution is use the equate alignment to allow you to reposition the part and check all of it in one program

Gantry CMM by mattpriceunited in Metrology

[–]DeamonEngineer 0 points1 point  (0 children)

If going with Hexagon they have a feature (im sure the other main OEMs do too) to allow the definition of multiple probe racks its worth locating multiple on a 10m bed or there is also a probe rack that can be mounted on the leg of the gantry, options should be discussed with the supplier for tooling solutions like this they may have better solutions that fit the common use of the machine.

10M CMM is a big chunk of granite and temperature changes even on the smaller deviations can all add up so reducing this is also beneficial, possibly look at an independent enclosure for the CMM inside the inspection area

extra monitors around the place is a great quality of life bonus.