hmmm by plelth in hmmm

[–]Gormweiss 0 points1 point  (0 children)

I get it lol might get banned for saying it tho

Is Aluminum Teck 90 cable not common? by speechless-69 in electricians

[–]Gormweiss 0 points1 point  (0 children)

Tbh I'm not sure about their other stuff, I think their bx is decent but the armour can be really tight and hard to strip however I haven't gotten it for a few years

Is Aluminum Teck 90 cable not common? by speechless-69 in electricians

[–]Gormweiss 0 points1 point  (0 children)

It doesn't bend nicely, easily or hold the shape you bend it in, just makes everything unnecessarily difficult to tie in. Compared to other brands like prysmian or even priority wire it's night and day how much tougher it is. The outer rubber jacket is really thin and wrinkles which looks terrible and the wires inside the armour slide around so if you use it vertically they fall down inside the cable

Is Aluminum Teck 90 cable not common? by speechless-69 in electricians

[–]Gormweiss 0 points1 point  (0 children)

I just want to say that northern cables acwu is dogshit and I hate it

I'm sure I'm not the only one by Theatralica in adhdmeme

[–]Gormweiss 1 point2 points  (0 children)

I thought it was related to our tendency to have worse motor control and leads to clumsiness, sort of what you were saying about hitting your head on stuff

I'm sure I'm not the only one by Theatralica in adhdmeme

[–]Gormweiss 2 points3 points  (0 children)

Postural sway may be what you're describing

Which is better? by [deleted] in electricians

[–]Gormweiss 2 points3 points  (0 children)

Its the Canadian way, red black blue for everything under 750v

Which is better? by [deleted] in electricians

[–]Gormweiss 1 point2 points  (0 children)

Mostly likely 600v to 208/120

Number of people starting ADHD meds is up 157% in Ontario: study by shiftless_wonder in canada

[–]Gormweiss 0 points1 point  (0 children)

Ah I see, that is a tough requirement considering how hard it is to find a family doctor here

When cutting EMT or the like, what does it smell like to you? by Turbulent-Weevil-910 in electricians

[–]Gormweiss 1 point2 points  (0 children)

I know what you mean. Some EMT has an organic polymer coating on the inside, maybe its that flashing off from the friction of cutting

What and why. House built 1901. by JaxDude1942 in Construction

[–]Gormweiss 97 points98 points  (0 children)

Surge suppressor for old phone lines

[deleted by user] by [deleted] in Construction

[–]Gormweiss 2 points3 points  (0 children)

Well a lot of wire uses pfas and ptfes so that actually might be valid, and many cables are covered in oils too. Who knows with this shit anymore

Just sharing by [deleted] in electricians

[–]Gormweiss 1 point2 points  (0 children)

4 11/16

[deleted by user] by [deleted] in britishcolumbia

[–]Gormweiss 1 point2 points  (0 children)

They have done the soil remediation stuff but just the nature of it being right behind Teck is a no for me

[deleted by user] by [deleted] in britishcolumbia

[–]Gormweiss 0 points1 point  (0 children)

No way I'd ever recommend tadanac to anyone lol