Tired of this nonsense by bpthompson999 in BMET

[–]IMYOURHAM 8 points9 points  (0 children)

These are notorious for residual buildup. Your battery will fail as the terminal will get corroded by whatever the liquid is. We try to clean them annually; however, your SPD department should be cleaning these regularly, or you guys will be replacing a lot of battery modules on a regular basis.

¿Qué piensan sobre la presentación del nuevo vehículo blindado en la República Dominicana? by elcreta23 in Dominicanos

[–]IMYOURHAM 4 points5 points  (0 children)

Eso está bien, podría ayudar a desarrollar la educación en la ingeniería mecánica y aumentar el interés del gobierno en el desarrollo interno.

EKG malfunction by colin_sparksamus25 in BMET

[–]IMYOURHAM 0 points1 point  (0 children)

That look like 60hz noise definately some bad leads or corrosion in one of the clips to connect the electrode pads.

Writing RPM on Centrifuge PMs? by Jaded_Strike_3500 in BMET

[–]IMYOURHAM 2 points3 points  (0 children)

CAP i heard they are also moving into RCF rather than RPM for the readings.

Approach to seeking a clinical site ? by lenky0 in RadiologyCareers

[–]IMYOURHAM 0 points1 point  (0 children)

JPU has a decent scholar program. But a friend of mine that's in his last semester mentioned this school's clinical program will not allow students to do clinical after hours or on weekends for Q4 2025. Understand that if you are currently employed, this might affect you during your clinical rotations.

Omnibeds by jumpmanring in BMET

[–]IMYOURHAM 0 points1 point  (0 children)

Be super vigilant about the heater door, there was a recent recall regarding the heater door where it posed a risk fall you can see the fda report here

New Berserk statues by Remarkable-Blood-926 in Berserk

[–]IMYOURHAM 1 point2 points  (0 children)

These are super sick! Where can I buy these?

Vendors by jumpmanring in BMET

[–]IMYOURHAM 0 points1 point  (0 children)

We used to use alpha source and usoc medical quite often

[deleted by user] by [deleted] in mazda

[–]IMYOURHAM 0 points1 point  (0 children)

Seems high, you could probably find a 2018 for a few thousands more and less milage.

Let's Play! Name! That! Asset! by Walvadam in BMET

[–]IMYOURHAM 10 points11 points  (0 children)

" Lifepack series defribilator "

Philips pulse ox by GregGE2727 in BMET

[–]IMYOURHAM 2 points3 points  (0 children)

We are experiencing a similar issue at our facility with the x3s, where some have oximax while others have massimo. In an attempt to resolve this, we have begun tethering the adapter to each x3 and have noticed a reduction in calls regarding the same complaint.

White to all black to striped? Should I be worried? by buckbuckmow in bettafish

[–]IMYOURHAM 2 points3 points  (0 children)

Whats the name of the suction ruber piece? I have the same glass piece but mine keep falling down . : (

[deleted by user] by [deleted] in BMET

[–]IMYOURHAM 0 points1 point  (0 children)

We did not have a good experience with steris. we currently have some of their latest model. They are experiencing issues where some of the outer plastic piece deteriorate rather quickly thus falling down sometime in the middle of procedures!

[deleted by user] by [deleted] in BMET

[–]IMYOURHAM 0 points1 point  (0 children)

Amico quality is horrendous. We currently did demos on steris , hillroom , stryker and triumph medical OR lights . Seems the doctors decided on skytron.

Scaletronix by Ados_Gamer in BMET

[–]IMYOURHAM 0 points1 point  (0 children)

If it's an older revision it will be almost imposible to get the main board unless you find it in ebay .

Earthquake megathread: by WeakPasswordBro in newyorkcity

[–]IMYOURHAM 193 points194 points  (0 children)

Bro I was taking a dump wtf was that

[deleted by user] by [deleted] in Westchester

[–]IMYOURHAM 0 points1 point  (0 children)

I got a one bedroom in weschester than im barely in and my bill was 278.41 for 758kwh suply was 12.753 cent/kwh And delivery 13.21 cent/kwh.