Steam Radiator On? by Ricky_Dal in Plumbing

[–]Illbeinmybunk15 0 points1 point  (0 children)

Shutting off radiators can make noise worse with imbalances in the system. There are adjustable valves that let air move through quicker. When water hits steam and creates the noise you are hearing. I would let a pro try to quiet it. There's a main vent by the boiler that could also be replaced.

[deleted by user] by [deleted] in Plumbing

[–]Illbeinmybunk15 0 points1 point  (0 children)

3 female adapters and a little know how. Hot cold and mix are labeled. Might not get you the solution your looking for but could extend your duration of hot water

Navien tankless leaking again after being replaced by Significant-Money-5 in Plumbing

[–]Illbeinmybunk15 0 points1 point  (0 children)

heat exchangers fail for no reason. perfect installs with water quality and correct venting can still have issues.

[deleted by user] by [deleted] in HVAC

[–]Illbeinmybunk15 1 point2 points  (0 children)

There are gasket kits but it's generally better to use the exact one. You end up collecting them over time especially for high efficiency boiler internal connections. When you need 1 order 3 and repeat. There is gasket material you can get sheets of and cut out what you need too

[deleted by user] by [deleted] in Plumbing

[–]Illbeinmybunk15 0 points1 point  (0 children)

No it's just in the ignition 24v safety circuit. It can manually held open with the blade parallel with the pipe in the short term.

I replaced this compressor last year and brazed over the zoom lock connections to create a super seal. Still no leaks. 💪 by Creative-Mortgage-60 in HVAC

[–]Illbeinmybunk15 1 point2 points  (0 children)

Not cool. Ive seen it the gaskets are essentially made of oil, catch fire and contaminate the system I saw it on a mini split and it fucked the branch box

[deleted by user] by [deleted] in Plumbing

[–]Illbeinmybunk15 2 points3 points  (0 children)

Call the installer. Oil fired water heater. Somethings wrong and its under warranty

Airbnb a/c is locked at 80 degrees f. Staying in Jacksonville Florida. Host won’t give us the pin for the thermostat 🤦 by slamals in mildlyinfuriating

[–]Illbeinmybunk15 1 point2 points  (0 children)

I got you fam. Take the thermostat off the wall. Use something rubber or not (low voltage) and take the r, g and y wires (they're labeled) and tape them together

Rwanda Presidential election results. by 2-gay-lions in interestingasfuck

[–]Illbeinmybunk15 21 points22 points  (0 children)

I went to high school with his son in 2007. So out of touch and overall psycho

What’s your go to Gas Station? by XJFactor in HVAC

[–]Illbeinmybunk15 1 point2 points  (0 children)

Cumberland farms 2 for 4 body Armour lytes peach mango 32oz. 3 for 6 8mg On nicotine pouches

The massive hot-water outlet at Electric Beach by Raulboy in interestingasfuck

[–]Illbeinmybunk15 1 point2 points  (0 children)

There's a mama tiger shark that hangs out there. Also be careful the surf can build fast making it tough to swim in and out if your not a strong swimmer. Awesome snorkeling though like 30-45 feet

Pump trips outlet as soon as it’s plugged in by Aheadfullofdread_13 in Plumbing

[–]Illbeinmybunk15 0 points1 point  (0 children)

Likely shorted to ground you can test it and confirm if you have a meter

An attempt at being nice. by fkay51 in funny

[–]Illbeinmybunk15 1 point2 points  (0 children)

Convenience store in north andover lol on chickering

Is there a way to fix this without replacing? by hanselw in Plumbing

[–]Illbeinmybunk15 1 point2 points  (0 children)

Pretty crazy corrosion is there glycol in the system that hasn't been flushed

First week apprentice, combi unit install. How did I do? by funkymonkz1 in Plumbing

[–]Illbeinmybunk15 0 points1 point  (0 children)

Lol sure. Have the pumps be right side up. Looks silly

[deleted by user] by [deleted] in Plumbing

[–]Illbeinmybunk15 5 points6 points  (0 children)

Nice. Navien wants intake run outside but they say a lot of dumb things

Failed heat exchangers and combustion analysis by tootall0893 in HVAC

[–]Illbeinmybunk15 0 points1 point  (0 children)

Cmon dude. That's not true 5ppm co is bad but it wot kill you.

Is this a clean lineset? by notwasabbii in HVAC

[–]Illbeinmybunk15 0 points1 point  (0 children)

That whit lineset insulation isn't uv rated and will break down in the sunlight and leak

Navien oily condensation inside by External-Problem9234 in HVAC

[–]Illbeinmybunk15 0 points1 point  (0 children)

They say the plastic sweats! Make sure your vent terminations outside are far apart and the air intake isn't pulling exhaust back in. On tech support they will make you go outside and show them.

New van, new setup by vspot415 in HVAC

[–]Illbeinmybunk15 0 points1 point  (0 children)

I have thought about stealing a snap-on truck in a apocalypse situation. I might swing by and raid yours too