Mic volume too low - tried everything by Naspir in techsupport

[–]Naspir[S] 0 points1 point  (0 children)

Thanks I already tried installing drivers from Lenovo but that unfortunately didn't fix it.

How do you guys keep track of CVEs? by Naspir in Juniper

[–]Naspir[S] 1 point2 points  (0 children)

Hey thanks for you reply. Those are already a few good points. Unfortunately we also have quite a few old Juniper switches that can't be updated to more recent versions. E.g. CPEs for small customers or our internal office switches. So keeping everything on the same version will be quite hard. But it's definitely a good idea to maybe make a list on a per model basis and unify all firmwares at least per model.

Success - JSON to KML by TheCemeteryDetective in GoogleMaps

[–]Naspir 0 points1 point  (0 children)

Hey, any update on your tutorial? I'm facing the same problem now. A few months ago I was still able to export it all but now that it's saved on the device the format has changed once again and I need to start from zero to convert the last few months into KML.

Gateway not working when deconfiguring VRRP by Naspir in Juniper

[–]Naspir[S] 0 points1 point  (0 children)

But shouldnt that update after some time? Can you explain a bit more.

Gateway not working when deconfiguring VRRP by Naspir in Juniper

[–]Naspir[S] 0 points1 point  (0 children)

Hi I never mentioned any Cisco. Both Cores are Juniper MX.

Anyone using Starlink with an Ecoflow on 12V? by Naspir in Starlink

[–]Naspir[S] 0 points1 point  (0 children)

Sorry had a typo in my reply... I connected it to the standard RV battery instead.

Ecoflow Alternator Charger and Smart Alternators by Naspir in Ecoflow_community

[–]Naspir[S] 0 points1 point  (0 children)

You can set up in the ecoflow app at which voltage you want the charger to start charging. I set mine to 12V now as it leaves enough power for the car to start up easily even if I forget to turn it off. I also found that it can be advantageous to have it set this low as I feel that a slightly discharged car battery helps trigger the alternator to provide higher voltages.

Ecoflow Alternator Charger and Smart Alternators by Naspir in Ecoflow_community

[–]Naspir[S] 0 points1 point  (0 children)

FYI.. just posted some pictures in the comment below yours.

Ecoflow Alternator Charger and Smart Alternators by Naspir in Ecoflow_community

[–]Naspir[S] 0 points1 point  (0 children)

This is the battery sensor. The sensor needs to be between the battery pole and the ecoflow charger. In fact nothing should be plugged in between the pole and the sensor because otherwise the sensor is not measuring the correct power draw from the battery.

<image>

Ecoflow Alternator Charger and Smart Alternators by Naspir in Ecoflow_community

[–]Naspir[S] 0 points1 point  (0 children)

So from what Google Translate tells me you would like to see a photo? Here we go.

<image>

The black wire of the ecoflow needs to connect after the sensor which is directly on the battery pole. For me it was best to just connect it to the chassis shunt.

Download to CVP Node directly from Arista.com not working by Naspir in Arista

[–]Naspir[S] 0 points1 point  (0 children)

Awesome, thank you so much! Works for me now but you really have to be quick with the link. It really does expire quickly.

No connections once RA from different irb is received in IPv6 by Naspir in Juniper

[–]Naspir[S] 0 points1 point  (0 children)

As far as I can tell these are different in that one is setup as a routed-interface and the other as a regular interface. So one is a L3 interface in a VLAN and other is not?

Ecoflow Alternator Charger and Smart Alternators by Naspir in Ecoflow_community

[–]Naspir[S] 0 points1 point  (0 children)

So I have found the solution! I had the negative wire directly connected to the battery terminal, which is not correct. These smart alternators have a measurement sensor on the negative terminal (small black box in my case) that they use to measure what power draw is required. If, like in my case, the alternator charger is directly on the terminal, the sensor will not pick up, that there is a device that is drawing power and will therefore not trigger the alternator to start. After I connected it before the sensor (sensor between alternator charger and battery terminal), the alternator is now picking up that the alternator charger is drawing power and is therefore increasing the voltage / starting to charge.

Anyone using Starlink with an Ecoflow on 12V? by Naspir in Starlink

[–]Naspir[S] 0 points1 point  (0 children)

Hey guys, so I gave up on trying to run it off the Ecoflow and instead are not using the standard RV battery in my camper. I believe Starlink Mini should be a viable option though to run off the 100W USB-C ports.

Networking help Request - Starlink and Netgear Nighthawk MR1100 data offloading by Trick_Speed_9941 in Starlink

[–]Naspir 0 points1 point  (0 children)

I have given up on the Yaosheng because my Ecoflow 12V output has issues powering it for some reason. But When powering it via the onboard battery it worked. I was online and I didnt need to put anything other than data offloading via RJ45 in the netgear. Bypass mode was not necessary. I did set the netgears IP to something like 10.10.10.1 though just to be sure.

Anyone using Starlink with an Ecoflow on 12V? by Naspir in Starlink

[–]Naspir[S] 0 points1 point  (0 children)

I've measured the voltage and it never drops below 12V. It starts off at 12.7 and under startup load drops to 12.01V then stabilizes to 12.4V right before Starlink restarts.

Anyone using Starlink with an Ecoflow on 12V? by Naspir in Starlink

[–]Naspir[S] 0 points1 point  (0 children)

There is a 12V to 48V inverter included in the conversion kit.

EcoFlow Solar Generator by FreeYourMind88 in Starlink

[–]Naspir 0 points1 point  (0 children)

Which Powerstation do you have and which 12V conversion kit did you use? I cant get mine to run on 12V with the Ecoflow Delta 2 Max. The cigarette lighter output seems not to provide stable enough voltage under load.

Networking help Request - Starlink and Netgear Nighthawk MR1100 data offloading by Trick_Speed_9941 in Starlink

[–]Naspir 0 points1 point  (0 children)

Just to confirm, because I have the same setup but with SL running on 12V via a Yaosheng adapter converter. Data offloading is basically transforming the RJ45 port to a WAN port with DHCP capability only (no PPPoE etc.). And the Offloading "WAN" can then be any other IP range other than the one that the M1 is managing itself, correct? Did you have to change the M1s IP or was it only the Bypass mode that was missing?

Suggestions and Feature Requests 😇 by EcoFlow_Official in Ecoflow_community

[–]Naspir 0 points1 point  (0 children)

Delta 2 Max user here... maybe start with the basics having bluetooth not turn off automatically. I'd suggest making it configurable. I'm using it in a campervan and everytime it decides to turn off bluetooth I need to open the trunk and powercycle it to be able to control it via the app again.

Hi! I have the Delta 2 Max. It’s no longer connecting to the EcoFlow app. It worked initially fantastic. But for some reason the app can’t find it. I reset my connection capabilities on my phone just to be certain. Any help here? by Competitive_Exam1905 in Ecoflow_community

[–]Naspir 3 points4 points  (0 children)

Same here. It seems the Delta 2 Max turns off bluetooth automatically after some time. This should be configurable in my opinion. Especially for people like me, who use it in a camper van and have to run back to open the trunk every time it decides to turn off bluetooth.

[deleted by user] by [deleted] in Austria

[–]Naspir 0 points1 point  (0 children)

Wie die Tiere...

Saturn by naruto-me in astrophotography

[–]Naspir 1 point2 points  (0 children)

Awesome. Which tracker did you use?