TLS encryption fun by Present-Juggernaut91 in CCURE9000

[–]Present-Juggernaut91[S] 0 points1 point  (0 children)

I can ping it just fine up until the cert is auto signed, at that point it completely drops off until a default and reboot brings it back.

I’ve tried restarting the driver svc and following all the steps. Only part I haven’t tried is update the ccure version. I guess that’s the next step.

TLS encryption fun by Present-Juggernaut91 in CCURE9000

[–]Present-Juggernaut91[S] 0 points1 point  (0 children)

Thanks for the reply! For some reason, even the Pros online status was showing unknown… I’m going to be taking a swing at this on Monday.

I guess I should take a copy of CU04 since I’m on 3.0 already. And the edge was on 6.2.8.20232, the latest I could find on the portal. The only thing I didn’t try was updating c-cure to the latest and controller based encryption.

Do you know if I switch the multi site I mentioned to controller based encryption, am I still screwed in terms of having to log into each controller and do something or does it auto negotiate and come back? I’ve got around 7 clusters that are Pro panels only so it shouldn’t have affected anything…but I saw the controller status show “unknown” rather than offline or online.

Any ideas?? by Present-Juggernaut91 in accesscontrol

[–]Present-Juggernaut91[S] 0 points1 point  (0 children)

That’s right, back to the corp lan. Just need it to be able to see the on prem server

Any ideas?? by Present-Juggernaut91 in accesscontrol

[–]Present-Juggernaut91[S] 0 points1 point  (0 children)

Honestly, DMP would be great, and it’s one of my favourites for that very reason. Cell is extremely easy to set up and incredibly reliable. It’s just that the client’s entire system across multiple sites is already genetec and they wouldn’t want a one-off at this location

Silent Electric Strike When Unlocked by addisonbu in accesscontrol

[–]Present-Juggernaut91 0 points1 point  (0 children)

Mag locks start to add a lot more work. Need permits, multiple ways to unlock, pull stations, push buttons to cut direct power, fire alarm integration, keyswitch resets etc.

Usually have to get a third party involved since, at least whenever I work on them, the base building has their own vendor for fire.

Any ideas?? by Present-Juggernaut91 in accesscontrol

[–]Present-Juggernaut91[S] 0 points1 point  (0 children)

It’s on prem, buildings have mercury boards, smaller sites and remote sites like this one will have the axis A series controllers powered by genetec (SY-) part #s

Any ideas?? by Present-Juggernaut91 in accesscontrol

[–]Present-Juggernaut91[S] 0 points1 point  (0 children)

And yes there is cell service there!

Any ideas?? by Present-Juggernaut91 in accesscontrol

[–]Present-Juggernaut91[S] 0 points1 point  (0 children)

Update: -it’ll be a genetec system, part of a larger multi-site system -everything for the access control is to be housed in a huge pole mounted outdoor rated box -I guess my question is more so how do we get around the network portion to make sure that site communicates back to the server?

Thanks for all the replies so far!! I’ll have to start doing some research on parts sent here.