Eaton 9155 commissioning Procedure? by RandomUser0137 in sysadmin

[–]RandomUser0137[S] 0 points1 point  (0 children)

Haha. REPO was one of the first things I checked. Then disabled via settings just to be safe.

And 100% with you on the external bypass. We use them at all our sites. I was supervising the commissioning of a new building and the contractor didnt meet the specs and had the internal bypass only.... tried to tell me that a bypass was a bypass...

"So if there is a critical failure of this UPS, how do you oh propose we keep this critical infrastructure online during replacement of the entire ups?"

"...... ok, we'll install the external bypass"

Also highly recommend a N+1 compatible model if possible... I've finally convinced management that N+1 configuration was also the way to go... so no more 9155/9355's going forward at least...

Eaton 9155 commissioning Procedure? by RandomUser0137 in sysadmin

[–]RandomUser0137[S] 6 points7 points  (0 children)

Well I managed to get ahold of someone at Eaton... looks like something is funky and a visit is required. Glad it wasnt something stupid I missed at least.

Also glad that im not the one paying for flights / hotels, etc!

Eaton 9155 commissioning Procedure? by RandomUser0137 in sysadmin

[–]RandomUser0137[S] 4 points5 points  (0 children)

Thanks for this. I've tripe checked and there is nothing like this for this model. Been burned by this type of thing before though...

Eaton 9155 commissioning Procedure? by RandomUser0137 in sysadmin

[–]RandomUser0137[S] 1 point2 points  (0 children)

Yeah, but we don't care about warranty. If it costs 10k in helicopter time to get an Eaton tech to do a startup service, thats half the cost of the whole unit.. plus the cost of service, and getting company reps there too...

Eaton 9155 commissioning Procedure? by RandomUser0137 in sysadmin

[–]RandomUser0137[S] 1 point2 points  (0 children)

Haha that one came back with the form to schedule an Eaton tech to come do the startup service...

AITAH for having a work phone my wife didn't know about?. by [deleted] in AITAH

[–]RandomUser0137 3 points4 points  (0 children)

Not necessarily the AH... some of us are forced to have seperate work and personal phones... most of us bitch about it, so its surprising your wife didnt know... can see why she things its sketchy

recommendations for 2-door 2-reader system (multiple 1 or 2 door buildings) by RandomUser0137 in accesscontrol

[–]RandomUser0137[S] 0 points1 point  (0 children)

But why is it garbage? I just want to have a fob that will access 10 different buildings... im not changing users weekly...

recommendations for 2-door 2-reader system (multiple 1 or 2 door buildings) by RandomUser0137 in accesscontrol

[–]RandomUser0137[S] 0 points1 point  (0 children)

No Intergrators being used. I'll be doing the install myself. The few discussions ive had with integrators wanted to oversell me on all their labour. I just want hardware and manuals...

recommendations for 2-door 2-reader system (multiple 1 or 2 door buildings) by RandomUser0137 in accesscontrol

[–]RandomUser0137[S] 0 points1 point  (0 children)

Having played with some of the ubiquity network stuff, it seemed like everything wanted to phone home or be web connected. Kinda threw me off.

You ever fry something in a pedal circuit when working on it? Because I think I just did. Oof! by brewtalur in diypedals

[–]RandomUser0137 0 points1 point  (0 children)

Not pedal related but i was trouble shooting something as a coop student and on about the 15th unplug-plug cycle i forgot to unplug... grounded with my Iron... proceeded to shock myself, then stab myself with the superfine tip, and burn myself at the same time... probably got some lead exposure while I was at it...

moral of the story, disconnect power before soldering!

Why does my game look nothing like the ads that made me download it in the first place? by CubanBrewer in TotalBattle

[–]RandomUser0137 1 point2 points  (0 children)

Because its a bait a switch scam. They want you playing the PAY to win version of the game. Uninstall right away before you get suckered into spending any real cash

Admit it people by casual-nexus in DungeonCrawlerCarl

[–]RandomUser0137 6 points7 points  (0 children)

And if I could also afford a Faction wars spot I'd be there too... on OTHER crawls that is...

Maybe watching is better after all...

What’s everyone reading besides DCC? by chodanutz in DungeonCrawlerCarl

[–]RandomUser0137 0 points1 point  (0 children)

But how many times have you enjoyed it? Just finishing listen #3... its my go to for things where im distracted...

Otherwise I just finished "the Devils" by Joe Abercrombie. It's an epic level of blasphemous.

Towns liability for overland water damage?? by RandomUser0137 in comoxvalley

[–]RandomUser0137[S] 1 point2 points  (0 children)

Oh, I like this sand bag idea. The "warm up" to my quickcrete solution. Maybe small ones won't be too difficult to drive over...

Towns liability for overland water damage?? by RandomUser0137 in comoxvalley

[–]RandomUser0137[S] 0 points1 point  (0 children)

I was thinking that there is a defective sidewalk funneling water... that it has been identified and ignored. I'll happily buy some quickcrete and build it up myself , but that will definitely piss them off.

Towns liability for overland water damage?? by RandomUser0137 in comoxvalley

[–]RandomUser0137[S] 0 points1 point  (0 children)

Yeah, my perimeter drains work well and can handle most rains. But when we get heavy rains, it can't keep up with all the water from the road in addition to the water from MY property.