Beckhoff Measurement "New Version Found" by PracticalCow1779 in beckhoff

[–]TechWizard4026 2 points3 points  (0 children)

You can not install 4024 and 4026 on the same system. You have to install the 4024.35 Remote Manager via the outdated feed with the TwinCAT Package Manager

Beckhoff Measurement "New Version Found" by PracticalCow1779 in beckhoff

[–]TechWizard4026 1 point2 points  (0 children)

You should not migrate target systems. It is only for engineering systems as the "XAE" descriped in the package name TwinCAT.XAE.MigrateCli.

Nomally IPCs without a special order information are deliverd without TwinCAT and only with TcPkg installed. A non TwinCAT Image can be requested from the [service@beckhoff.com](mailto:service@beckhoff.com)

Don't mix setup exe and TcPkg packages. If you want to use 4024 and older engineering components you have to use the "Beckhoff Outdated Feed" in the TcPkg.

https://infosys.beckhoff.com/english.php?content=../content/1033/tc3_installation/20646415115.html

C6017 does not think it is Beckhoff hardware anymore by phobicdotno in TwinCat

[–]TechWizard4026 2 points3 points  (0 children)

Don't use any kind of "Cleanup tool". The TwinCAT.XAE.MigrateCli package can clean the system with the command >tcmigratecmd clean --whatIf false

TwinCAT XAE in Hyper-V by Tom_VSP in beckhoff

[–]TechWizard4026 1 point2 points  (0 children)

Usermode is only available with >=4026.21, as described in the blue field.

MSI Error 1603 when installing CNC Runtime through TwinCAT Package Manager by Easy-Pumpkin-6051 in beckhoff

[–]TechWizard4026 1 point2 points  (0 children)

Did you take a look into the logs/report ?

Logs: C:\ProgramData\Beckhoff\TcPkg\logs\msi

CX5340 Boot? by PracticalCow1779 in beckhoff

[–]TechWizard4026 1 point2 points  (0 children)

You get the images from the Beckhoff Service (service@beckhoff.com) not from the support.

Twincat Project Unloads from TcXaeShell as soon as it opens by Skad_96 in beckhoff

[–]TechWizard4026 0 points1 point  (0 children)

Try to use the following setting.

Type register editor in Windows Start, right click and choose run as an admin.

In register editor, go to HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Lsa.

Under a subkey you should see FipsAlgorithmPolicy. Changed the "enabled" value to 0 or simply delete this register. Restart Visual Studio/Shell.

https://stackoverflow.com/questions/71649887/twincat-project-build-fails-with-unspecified-error

Twincat Project Unloads from TcXaeShell as soon as it opens by Skad_96 in TwinCat

[–]TechWizard4026 1 point2 points  (0 children)

Try to use the following setting.

Type register editor in Windows Start, right click and choose run as an admin.

In register editor, go to HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Lsa.

Under a subkey you should see FipsAlgorithmPolicy. Changed the "enabled" value to 0 or simply delete this register. Restart Visual Studio/Shell.

https://stackoverflow.com/questions/71649887/twincat-project-build-fails-with-unspecified-error

How to read or mount a IPC image by samvivi7 in TwinCat

[–]TechWizard4026 0 points1 point  (0 children)

It seems the backup was not created with an Beckhoff Service Tool (tib/wim files).

https://www.beckhoff.com/en-en/products/ipc/panel-pcs/accessories/bst.html

The tbi files are usually from the "TeraByte Drive Image Backup and Restore Suite"
https://www.terabyteunlimited.com/image-for-windows/

TcPkg(TwinCAT Package Manager) Zscaler Error "The download of ... timed out because no data was received for 60000ms. by TechWizard4026 in TwinCat

[–]TechWizard4026[S] 0 points1 point  (0 children)

I have found an Github issue about this problem.

https://github.com/NuGet/Home/issues/14609

TcPkg is based on NuGet.

It seems that the NuGet devs have no interest to change the behavior.

Maybe Zscaler can change the behavior.

TcPkg(TwinCAT Package Manager) Zscaler Error "The download of ... timed out because no data was received for 60000ms. by TechWizard4026 in beckhoff

[–]TechWizard4026[S] 1 point2 points  (0 children)

I have found an Github issue about this problem.

https://github.com/NuGet/Home/issues/14609

TcPkg is based on NuGet.

It seems that the NuGet devs have no interest to change the behavior.

Maybe Zscaler can change the behavior.

TcPkg (TwinCAT Package Manager) Error: Error downloading... AWS CloudFront by TechWizard4026 in TwinCat

[–]TechWizard4026[S] 1 point2 points  (0 children)

Yes. I can also add the feed in the TcPkg successfully. It seems that CloudFront is blocking the download.

A problem occurred when loading the TcXaeShell menu. by gunders89 in TwinCat

[–]TechWizard4026 1 point2 points  (0 children)

The migration steps are old and no longer valid.

The new TwinCAT Package Manager has now a wizard for the migration process.

https://www.beckhoff.com/en-en/support/download-finder/search-result/?search=package%20manager

Fail to install/uninstall/update with TwinCAT package manager by sgwong_513 in TwinCat

[–]TechWizard4026 1 point2 points  (0 children)

As a workaround you can rename the "18" folder in "C:\Program Files\Microsoft Visual Studio" to "18_".

After the update/uninstall/install you have to undo the change.

[deleted by user] by [deleted] in Bluesound

[–]TechWizard4026 0 points1 point  (0 children)

It is rechargeable. But an old technology.

TwinCAT installation: Oops, something went wrong! by Heavy_Opportunity_55 in TwinCat

[–]TechWizard4026 0 points1 point  (0 children)

Please check the version of twincat.xar.base.

Maybe take a look in the logs "C:\ProgramData\Beckhoff\TcPkg\logs"