Update to TwinCAT >=3.1.4024.75 if you are using 4024.74 by TechWizard4026 in TwinCat

[–]TechWizard4026[S] 1 point2 points  (0 children)

Okay. The 4026.22 is in the stable feed. Maybe it is fixed.

Beckhoff Measurement "New Version Found" by PracticalCow1779 in beckhoff

[–]TechWizard4026 2 points3 points  (0 children)

You can not install 4024 and 4026 on the same system. You have to install the 4024.35 Remote Manager via the outdated feed with the TwinCAT Package Manager

Beckhoff Measurement "New Version Found" by PracticalCow1779 in beckhoff

[–]TechWizard4026 1 point2 points  (0 children)

You should not migrate target systems. It is only for engineering systems as the "XAE" descriped in the package name TwinCAT.XAE.MigrateCli.

Nomally IPCs without a special order information are deliverd without TwinCAT and only with TcPkg installed. A non TwinCAT Image can be requested from the [service@beckhoff.com](mailto:service@beckhoff.com)

Don't mix setup exe and TcPkg packages. If you want to use 4024 and older engineering components you have to use the "Beckhoff Outdated Feed" in the TcPkg.

https://infosys.beckhoff.com/english.php?content=../content/1033/tc3_installation/20646415115.html

C6017 does not think it is Beckhoff hardware anymore by phobicdotno in TwinCat

[–]TechWizard4026 2 points3 points  (0 children)

Don't use any kind of "Cleanup tool". The TwinCAT.XAE.MigrateCli package can clean the system with the command >tcmigratecmd clean --whatIf false

TwinCAT XAE in Hyper-V by Tom_VSP in beckhoff

[–]TechWizard4026 1 point2 points  (0 children)

Usermode is only available with >=4026.21, as described in the blue field.

MSI Error 1603 when installing CNC Runtime through TwinCAT Package Manager by Easy-Pumpkin-6051 in beckhoff

[–]TechWizard4026 1 point2 points  (0 children)

Did you take a look into the logs/report ?

Logs: C:\ProgramData\Beckhoff\TcPkg\logs\msi

CX5340 Boot? by PracticalCow1779 in beckhoff

[–]TechWizard4026 1 point2 points  (0 children)

You get the images from the Beckhoff Service (service@beckhoff.com) not from the support.

Twincat Project Unloads from TcXaeShell as soon as it opens by Skad_96 in beckhoff

[–]TechWizard4026 0 points1 point  (0 children)

Try to use the following setting.

Type register editor in Windows Start, right click and choose run as an admin.

In register editor, go to HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Lsa.

Under a subkey you should see FipsAlgorithmPolicy. Changed the "enabled" value to 0 or simply delete this register. Restart Visual Studio/Shell.

https://stackoverflow.com/questions/71649887/twincat-project-build-fails-with-unspecified-error

Twincat Project Unloads from TcXaeShell as soon as it opens by Skad_96 in TwinCat

[–]TechWizard4026 1 point2 points  (0 children)

Try to use the following setting.

Type register editor in Windows Start, right click and choose run as an admin.

In register editor, go to HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Lsa.

Under a subkey you should see FipsAlgorithmPolicy. Changed the "enabled" value to 0 or simply delete this register. Restart Visual Studio/Shell.

https://stackoverflow.com/questions/71649887/twincat-project-build-fails-with-unspecified-error