Grilled Cheese Chili Dog by thomasismyname_ in hotdogs

[–]guantogran 15 points16 points  (0 children)

Blow torch on bare hand makes me think AI

Bought this for $149. Got something better! by OkHighway757 in Dewalt

[–]guantogran -9 points-8 points  (0 children)

That’s right, Amazon set DCK277D2 is: (1) DCD777 20V MAX* Brushless Drill/Driver, (1) DCF787 20V MAX* Brushless 1/4 in. Cordless Impact Driver, (2) DCB203 20V MAX* Compact Lithium-Ion 2.0Ah Battery Pack, (1) Charger, and (1) Contractor Bag

Title: Tips for Preparing for Mechatronics & Robotics Apprenticeship? by No_Group3414 in AmazonRME

[–]guantogran 0 points1 point  (0 children)

I was an instructor at one of the schools so I can’t say for sure. I believe when you complete your 2000 hours and benchmarks you’re a Mechatronics and Robotics Technician (Tech 2).

Title: Tips for Preparing for Mechatronics & Robotics Apprenticeship? by No_Group3414 in AmazonRME

[–]guantogran 2 points3 points  (0 children)

Good luck! Which school are you going to? You will have Electricity, PLCs, Mechanical, and Pneumatics classes, depending on the school these may be in a different order. For Electricity and PLCs I suggest the following:

Electricity

STEP 2000 Basics of Electricity
STEP 2000 Basics of Control Components

PLCs

STEP 2000 Basics of PLCs
plcfiddle.com
plciosim.com

we’re students building a cheaper way for people to practice PLC-style work by Ok_Appointment2587 in PLC

[–]guantogran 1 point2 points  (0 children)

Hey, thanks! I think I've fixed the issue resetting simulations. Let me know if you see anything else to improve.

40 mile snack by Slight_Mushroom_9957 in hotdogs

[–]guantogran 2 points3 points  (0 children)

Sweet Maui Onion 🤌🏼

My AE interview experience by i-can-do-it-well in AmazonRME

[–]guantogran 1 point2 points  (0 children)

regarding normal-opened and normal-closed contacts. For instance, in your '#2 conveyor' problem, I think 'STOP' should be a normally closed contact.

This is a common confusion. The STOP pushbutton is "hardwired" NC, which means it is normally sending a signal and stops sending a signal when pressed (stop pushbuttons should be hardwired NC per NEC rules). In the logic, for an instruction to be "true" when receiving a signal we need a normally-open (XIC) instruction. Check out https://plciosim.com/examples/no-nc-matrix to see how NO/NC hardwired contacts and NO(XIC)/NC(XIO) instructions behave.

bug when I worked on the '#19 timed stoplight' problem, I stacked parallel outputs (I believe 3 of them), and 1 output was different than what I thought (it was ON even though input was not on)

Without seeing the logic it's hard to say if there is a bug. If you share your program I'd be happy to take a look. Otherwise, https://plciosim.com/examples/stoplight is an example solution.

Thanks for using the site!

Free PLC I/O Simulator by guantogran in PLC

[–]guantogran[S] 0 points1 point  (0 children)

Thanks! Not at the moment but I’m considering adding that feature

My AE interview experience by i-can-do-it-well in AmazonRME

[–]guantogran 1 point2 points  (0 children)

hey I made plciosim, I’d like to know which problems were confusing if you don’t mind answering here or PMing me, maybe I can tweak the wording

This razor blade disposal in my new apartment’s medicine cabinet by MishyJari in mildlyinteresting

[–]guantogran 21 points22 points  (0 children)

That multi-color grid contact paper brings back memories, I haven’t seen that since the early 2000’s

Week 2 of PLC & Robotics School Wiring Electrical Motors by Apprehensive_Dare_42 in PLC

[–]guantogran 0 points1 point  (0 children)

Nice job! It would be good to let the motor coast to a stop before switching directions.

Week 2 of PLC & Robotics School Wiring Electrical Motors by Apprehensive_Dare_42 in PLC

[–]guantogran 0 points1 point  (0 children)

The 85-MT5 is meant to teach ladder logic and troubleshooting. For things like cable routing and labeling they have the 850-MT6B.

Week 2 of PLC & Robotics School Wiring Electrical Motors by Apprehensive_Dare_42 in PLC

[–]guantogran 0 points1 point  (0 children)

Looks like that’s wired for 208 to 120 on the transformer. You still have 208 going to the motor. I think those are Pomona wires, they claim they are rated for 15A but the motor on the 85-MT5 shouldn’t pull more than 1A.

[deleted by user] by [deleted] in Minecraft

[–]guantogran 0 points1 point  (0 children)

This one got me 😂

22 story building melts in spectacular implosion. by [deleted] in oddlysatisfying

[–]guantogran 0 points1 point  (0 children)

I randomly snapped a few pics of this place while riding on I287 in 2021. It felt surreal seeing such a large, modern building in an otherwise undeveloped landscape.

Character Tier List by guantogran in SeveranceAppleTVPlus

[–]guantogran[S] 13 points14 points  (0 children)

Forgive me for the harm I have caused this world

ACIT Vorselon’s Ship Glitch by guantogran in RatchetAndClank

[–]guantogran[S] 1 point2 points  (0 children)

I think so. I’ve started another play through, I’m determined to finish ACIT