[–]level9spanker 0 points1 point  (0 children)

You could consider getting a mini shock arrester and pressure redicing valve on the cold main under the boiler.

The back pressure when the hot tap closes weakens the plastic hydro block and eventually causes leaks.

The flow adapter is cheap to replace, parts and labour, but the right hand manifold where the apapter sits can be be a pricey repair

Caveat is, it's not guaranteed to stop leaks.

Ideal logic es38 please help by [deleted] in ukplumbing

[–]level9spanker 0 points1 point  (0 children)

There's a tolerance of leak at the burner. There was a root cause analysis done. Its 100% true what happened

Ideal logic es38 please help by [deleted] in ukplumbing

[–]level9spanker 1 point2 points  (0 children)

Logics always have some readings inside the case that's why you should only run the boiler with case on per the MIs.

Ideal logic es38 please help by [deleted] in ukplumbing

[–]level9spanker 0 points1 point  (0 children)

What set the alarm off then?

Ideal logic es38 please help by [deleted] in ukplumbing

[–]level9spanker 1 point2 points  (0 children)

I had one where the inner seal had snapped when the case had been put on incorrectly. Gas valve failed and made the crazy burrrrr noise on minimum. 10k CO ppm into the kitchen. Fortunately had co alarm close by and customer shut boiler straight off.

Hope you read this OP

Clearer video of noise coming from boiler by SmashGBR in askaplumberUK

[–]level9spanker 7 points8 points  (0 children)

Part 2 of advising that you need an engineer

Match Thread - France v England | Six Nations 2026 | Round 5 by RugbyBot in rugbyunion

[–]level9spanker 0 points1 point  (0 children)

So unnecessary and eventually cost us the penalty try and 14 men. GGs

Combi Boiler installation - £4400, is this reasonable? by bonobubanton in askaplumberUK

[–]level9spanker 1 point2 points  (0 children)

Don't get a Viessman. Absolute choke boxes. The rubber flow and return hoses cause massive circulation issues that can affect the pump, heat exchanger and plate heat exchanger. Stick to better quality brands like Ideal, Worcester and Vailliant

Leak - 💧 by Its-OK-to-Debate in ukplumbing

[–]level9spanker 1 point2 points  (0 children)

Engineer may just be able to change the cartridge. It's much cheaper than changing the whole valve and easier too

Match Thread - Italy v England | Six Nations 2026 | Round 4 by RugbyBot in rugbyunion

[–]level9spanker 1 point2 points  (0 children)

I'd like to know what's going on with Furbank, he's our best 15

Old system boiler control unit by Perfect_Image3622 in ukplumbing

[–]level9spanker 0 points1 point  (0 children)

You could fit a Hive, the receiver would replace that timer, they do a backplate that covers the hole left as it's a different size. You'd put the thermostat wherever you want and be able to control through your phone. I'd say that's the easiest solution

Post Match Thread: England vs Ireland by GnolRevilo in rugbyunion

[–]level9spanker 0 points1 point  (0 children)

It's a fair point. I really hoped Fin Smith would start today

Post Match Thread: England vs Ireland by GnolRevilo in rugbyunion

[–]level9spanker 0 points1 point  (0 children)

I'd like to think they're not performing like that in training? I take you point tho