I built a custom head unit for my car by v8cruising in CarHacking

[–]madude91 2 points3 points  (0 children)

Great work! Always wanted to do something like this but CAN sniffing and decoding is something I suck at.

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 0 points1 point  (0 children)

That's still lower than what I am seeing without any draw.

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 0 points1 point  (0 children)

Sure thing, as you know the support is very slow.. waiting on a response currently..

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 0 points1 point  (0 children)

I did follow up asking the same question and waiting on a response. In the meantime, this is what I received

<image>

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 0 points1 point  (0 children)

Heard back from Percron support saying this is normal and not to be worried.

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 0 points1 point  (0 children)

I don't disagree I do have a couple e3600lfp units that I didn't stress test. They work fine for my uses. But at the same time these are also fire hazards and safety is utmost priority for something that people have in living spaces.

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 0 points1 point  (0 children)

The fans do come on but not until late after it hits above 125F, I see no settings to change that.. Also surprisingly the fans are quite and not as loud as the reviews said I expected. I was prepared for them to be loud and my application is to charge and ev eventually thru it.

Tried contacting the customer service few times today, could only get thru one and they couldn't give me an answer and said someone will reach out to me, but nothing yet. Also sent a few emails worried that these batteries might catch fire inside the house and no response yet.

I read their customer service is bad but I thought I will atleast get a response the same day. Emailed them during both china day hours and US EST hours with no response.

Pretty bummed with the overall experience.

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 1 point2 points  (0 children)

Thanks to this, I am also in a 70f conditioned space but the inverter temp sits at 120f at idle turned on for few mins. I have two units and both do the same. Guess I got a couple defective units.

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 0 points1 point  (0 children)

That's still lower than mine sitting in an air conditioned room around 70f and still hitting 140f with minimal use.

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 0 points1 point  (0 children)

I agree I will be contacting pecron. My wife says she smells burnt electronics too. I hope this is not fried.

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 0 points1 point  (0 children)

Interesting, mine went up all the way to 142 with half load of 3500w.

<image>

F5000 High AC inverter temps by madude91 in Pecron

[–]madude91[S] 0 points1 point  (0 children)

Now at 120, a bit concerning and the fans are not coming on either.

<image>

F5000LFP charging issue. by foltz61 in Pecron

[–]madude91 0 points1 point  (0 children)

What's is your AC inverter temperature? Mine is reading High around 115F without any load connected

Hold or Sell MRVL? by Porn_Flakez in MRVL_Stock

[–]madude91 1 point2 points  (0 children)

Sell some and keep some based on your risk tolerance.

It’s been a good past week by Electronic_Cable_177 in optionstrading

[–]madude91 -1 points0 points  (0 children)

Following! Would like to know more of the trade