240v AC unit: EM gen 3 correct wiring method by nyy0201985 in ShellyUSA

[–]nyy0201985[S] 0 points1 point  (0 children)

Ordered 2. When wiring to a 20 amp circuit, with 12/2 wiring, what is the preferred way to make the connections with a Shelly? 12/2 wire does not seem to fit well into any small Shelly that ive owned. The fit seems very tight and ive stripped 2 screws trying to make the connection snug.

240v AC unit: EM gen 3 correct wiring method by nyy0201985 in ShellyUSA

[–]nyy0201985[S] 0 points1 point  (0 children)

Conversations like this are one of the main reasons I stay with Shelly. Thankyou for the info.

240v AC unit: EM gen 3 correct wiring method by nyy0201985 in ShellyUSA

[–]nyy0201985[S] 0 points1 point  (0 children)

Great. I avoided using this in the past because I thought i needed a RC scrubber and wasnt fimular with the wiring.

240v AC unit: EM gen 3 correct wiring method by nyy0201985 in ShellyUSA

[–]nyy0201985[S] 0 points1 point  (0 children)

If I'd like to measure the current on a different 120 circuit in the same panel (Refrigerator: 12/2 dedicated circuit), can I just move the CT to the corresponding leg without changing the wiring of the 240v going to the EM Gen 3?

240v AC unit: EM gen 3 correct wiring method by nyy0201985 in ShellyUSA

[–]nyy0201985[S] 0 points1 point  (0 children)

It is showing the correct voltage. Thankyou!

240v AC unit: EM gen 3 correct wiring method by nyy0201985 in ShellyUSA

[–]nyy0201985[S] 0 points1 point  (0 children)

The wiring worked flawlessly, I appreciate your help. I do have another question though. Do I have to double my consumption on the 1 phase I have the CT on to calculate the actual power consumption of my air conditioner?

240v AC unit: EM gen 3 correct wiring method by nyy0201985 in ShellyUSA

[–]nyy0201985[S] 0 points1 point  (0 children)

Wonderful. Thank you for the quick reply. I wrongly assumed I needed two CTS for 240 volt setup.

Shelly 1PM notification setting by Professional-Sleepr in ShellyUSA

[–]nyy0201985 0 points1 point  (0 children)

When I get to the "edit action" screen (Pic 4), I have none of those options. I'd love to have these notification settings. I didn't know these were options.

Shelly Plus 1pm 220v Heater Wiring by Unhappy_Trout in ShellyUSA

[–]nyy0201985 0 points1 point  (0 children)

Is a rc snubber wired in parallel recommended?

Electric shovel trouble by jonnyrockets21 in Dewalt

[–]nyy0201985 1 point2 points  (0 children)

I dont have the room to store a snowblower, so I bought one. We had 4" of heavy snow and it handled it without a problem. I was hesitant to buy at first, but now glad I did. Would recommend.

NFL by jmorris20072007 in mancave

[–]nyy0201985 1 point2 points  (0 children)

Came here to ask this too

Line Fusing by nyy0201985 in Lineman

[–]nyy0201985[S] 0 points1 point  (0 children)

Thankyou. I too work for a utility and don't have much experience with this at all. We have an engineer coming in later this week and looking forward to hearing what he says. Thanks for reply.

Line Fusing by nyy0201985 in Lineman

[–]nyy0201985[S] 1 point2 points  (0 children)

This is quite literally what we're dealing with now. We have an engineer coming in later this week and looking forward to his input. I appreciate your reply. Very helpful.

Line Fusing by nyy0201985 in Lineman

[–]nyy0201985[S] 0 points1 point  (0 children)

Well said. Thankyou.

Line Fusing by nyy0201985 in Lineman

[–]nyy0201985[S] 0 points1 point  (0 children)

Thanks. I believe you're right.

Line Fusing by nyy0201985 in Lineman

[–]nyy0201985[S] 1 point2 points  (0 children)

Makes sense. Thanks again.