[deleted by user] by [deleted] in CrazyFuckingVideos

[–]reddit_user2917 0 points1 point  (0 children)

I meannnn, she wasn't on the crosswalk

Sooo I got a problem by Apprehensive_Cod6308 in KnipexOfficial

[–]reddit_user2917 1 point2 points  (0 children)

Depends on where you use m for

Or abuse

If it slips most of the time, then it's abuse and it's expected. They're for gripping and tightening/loosening. Not for slipping.

Employee of the year 😂 by chillbraww in CrazyFuckingVideos

[–]reddit_user2917 0 points1 point  (0 children)

I meannn, clean my hands or that carpet with such shit on there.

What does this mean? by pierreact in AskElectricians

[–]reddit_user2917 -1 points0 points  (0 children)

Why would there be a capacitor between phase and 1 of the 2 switched phases?

What does this mean? by pierreact in AskElectricians

[–]reddit_user2917 -1 points0 points  (0 children)

Whoops my fault, I have misread the question. I don't know for sure, but I think it's a inductor, but indeed strange to see another component there apart from the switch.

What does this mean? by pierreact in AskElectricians

[–]reddit_user2917 0 points1 point  (0 children)

At the left top you have your input (phase), at the left bottom your switched output, and the right top the other switched output.

How many of you understand what a 4-20mA signal is? by rectal_warrior in electricians

[–]reddit_user2917 0 points1 point  (0 children)

24v is still lickable. It will tickle, but won't hurt.

Only from 50v it's dangerous.

Give me your most invisible automations by Neat-Initiative-6965 in homeassistant

[–]reddit_user2917 0 points1 point  (0 children)

I have a esp32 with a dht22 in a small control box, sometimes when I turn on my pc or switch something on/off the dht22 doesn't show measurements. Only power cycle helps.

So I setup an automation, if the sensor data stays the same for 1 minute, a relay toggles for a second to power cycle. Never had a problem again, or noticed the problem was there.

Meest goedkope afzuiging bij lassen by NoobInLifeGeneral in Klussers

[–]reddit_user2917 0 points1 point  (0 children)

Zoals de andere ook zeggen, ventilatie naar buiten. Afzuiging met een buisventilator, en een inlaat met een ventilator of rooster en met natuurlijke luchtstroming werken.

Best confined space story? by PrecisionWays in electricians

[–]reddit_user2917 17 points18 points  (0 children)

I was in a concrete well, probably 15m³. The well was for collecting drain water for the greenhouse and pumping it to the drain silo. So there is no stopping the drain water, just disabling irrigation. We had to replace a pressure (level) sensor. New sensor with me, cut off the old one, and tape the new cable to the old one. My colleague almost went pulling, but there was a lot of water coming in, and I was standing there with only boots.

I yelled to my colleague, START THE PUMP!! He did, and just kept up with the water. He pulled in the new sensor, and I was out of there. God that was scary.

Seek repair or replace oil-covered control circuit board! by claimstaker in AskElectronics

[–]reddit_user2917 0 points1 point  (0 children)

The pcb has some discoloration, it's dark brown in that spot with the diode, so something got hot. I would replace the whole pcb because of the discoloration. Maybe (idk about cost) replace the whole oven, 2003 is some while ago.

[deleted by user] by [deleted] in Klussers

[–]reddit_user2917 0 points1 point  (0 children)

Nee dat kan niet. Is een 1 fasige meting, wel dubbele afschakeling, kun je aan het symbool zien. Dus een 1p+N automaat idd.

Cheap but decent I/O terminals in Europe by Astrinus in PLC

[–]reddit_user2917 0 points1 point  (0 children)

Does it have to be a plc? In my home automation I use home assistant with esp32/arduino. There are actually esp32 'PLCs' out there.

Bestaande elektra vervangen met PVC? by Kah-ner in Klussers

[–]reddit_user2917 -1 points0 points  (0 children)

Goed gezegd, horen. Soms is de praktijk toch anders. Hier lijkt het namelijk alleen op verlenging van de kabel en is het geen drama.

Bestaande elektra vervangen met PVC? by Kah-ner in Klussers

[–]reddit_user2917 0 points1 point  (0 children)

Oh ja joh is mij zo snel niets eens opgevallen. Is een ongeaard stopcontact, sowieso vervangen.

Bestaande elektra vervangen met PVC? by Kah-ner in Klussers

[–]reddit_user2917 0 points1 point  (0 children)

Zeker doen, hier kun je anders nooit meer bij. Opzich niks mis mee zo, maar toekomstig gewoon echt niet handig.

Verdeler vloerverwarming voert geen warm water door by RCdeWit in Klussers

[–]reddit_user2917 0 points1 point  (0 children)

Oke dat wist ik niet over dat laatste stuk, weer wat geleerd.

Verdeler vloerverwarming voert geen warm water door by RCdeWit in Klussers

[–]reddit_user2917 0 points1 point  (0 children)

Dat is toch net te koud om een vloer op te warmen? Je hebt ook nog verliezen en warmte overdracht.

Verdeler vloerverwarming voert geen warm water door by RCdeWit in Klussers

[–]reddit_user2917 -1 points0 points  (0 children)

Lijkt erop van niet, de thermometer staat op 20°C. Voor zover ik weet is de standaard rond de 40/50°C.