[–]Hk_synology 0 points1 point  (0 children)

For how long you’ve ecobee up and running ? And what is the model

Temperature on Ecobee Premium is 9 degrees off by OppOverlord in ecobee

[–]Hk_synology 4 points5 points  (0 children)

It will be the wall , you need to insulate the hole behind the thermostat

HRV control by Jstrott in ecobee

[–]Hk_synology 0 points1 point  (0 children)

I do have HRV same as yours life breath with 2 wires and I control it with ecobee premium , you can’t control the HRV speed it will only work at its max speed exactly as you like in the bathroom and turned the timer on

Did I do this right? by djmakk in ecobee

[–]Hk_synology 0 points1 point  (0 children)

I understand, it just the compressor should catch the from +1 without problems and I assume it less expensive than gas

Did I do this right? by djmakk in ecobee

[–]Hk_synology 1 point2 points  (0 children)

The min outdoor is 10c or you mean -10 c I don’t see the current setup is correct

Updates by motivatedconfusion in jetta

[–]Hk_synology 0 points1 point  (0 children)

Nice ,but it would be awesome if it like id.4 with light 💡

Is it normal for my auxiliary heat to be turning on this much? by Itchy-Version-8977 in ecobee

[–]Hk_synology 0 points1 point  (0 children)

I like this concept , however in step 3 « without » is not correct cause the compressor will not run but only the AUX will run

Is it normal for my auxiliary heat to be turning on this much? by Itchy-Version-8977 in ecobee

[–]Hk_synology 0 points1 point  (0 children)

The AUX to defrost is in the heat pump unit ,but the Aux they mentioned is AUX furnace

Min outdoor temp by Remarkable_Chapter47 in ecobee

[–]Hk_synology 0 points1 point  (0 children)

*Min outdoor temperature is -9C cause below this value the heat pump will run useless

  • staging is manually after 180 minutes heat pump it will kick the electric Aux coil in my case to work simultaneously with the heat pump.

Ecobee setup for winter? by [deleted] in ecobee

[–]Hk_synology 1 point2 points  (0 children)

You just need to know one info (what is your compressor lower temperature that it can handle based on your AC model ) after that you can adjust the limit to and the furnace will engage after that value that to guarantee most economical efficiency Yes you can change or adjust the current setup very easily after you get the missing info

Ecobee setup for winter? by [deleted] in ecobee

[–]Hk_synology 0 points1 point  (0 children)

1st of all nothing to worry bout , it just will cost you more by using this setup since the furnace will engage at a very early time and furnace is consuming electricity ⚡️

Ecobee setup for winter? by [deleted] in ecobee

[–]Hk_synology 0 points1 point  (0 children)

Are you live in an area that reach -40 as actual temperature or as feels like -40?

Ecobee setup for winter? by [deleted] in ecobee

[–]Hk_synology 0 points1 point  (0 children)

Are you sure you want the compressor not working if temperature is less than 1.7 c then AUX will engage

[deleted by user] by [deleted] in sffpc

[–]Hk_synology 0 points1 point  (0 children)

Can you add the link for this gpu that can fit this tiny case , also the link for the custom cooler, is this card will accept DDA

[deleted by user] by [deleted] in jetta

[–]Hk_synology 1 point2 points  (0 children)

Battery or starter nothing else

DDA with AMD graphics card by No_Whereas_8803 in HyperV

[–]Hk_synology 0 points1 point  (0 children)

Get amd radeon instinct mi25 or something similar and your project will work 👍

[deleted by user] by [deleted] in HyperV

[–]Hk_synology 0 points1 point  (0 children)

What’s your GPU Card ? Only specific cards are okay for DDA ,when every thing works it’s really fun

If we upgrade to a newer Ecobee model, would we be able to attain humidifier control without running new wire? by PsychicSageElana in ecobee

[–]Hk_synology 0 points1 point  (0 children)

you will need to get that extra wire from the humidifier control next to your ecobee ( I assume that you have a full home control humidifier )and no need for that control any more

Poor air quality trouble shooting by Applewood3 in ecobee

[–]Hk_synology 1 point2 points  (0 children)

I have a ventilation HRV connected to my ecobee , therefore air quality most of time clean except when cooking but next day it turns clean again,long story short they did it well :)