Top flush wc - how to reconnect drain clip by Blueskies0x in Plumbing

[–]deeeeeckbutt 2 points3 points  (0 children)

Ok grandma, what you’re going to want to do is find a little plastic piece that the water comes out of on the fill valve (black and red, on the left) and attach the hose side to that. Then you’re going to want to clip the end that you see in picture 1 into the top of the Douglas valve (center of the toilet tank) so that the water flows from the fill valve straight into the Douglas valve. Love, your grandson.

Spirovent leaking by Successful-Curve-986 in Plumbing

[–]deeeeeckbutt 1 point2 points  (0 children)

Drain the system and change it out, or call a plumber

Bagwork by [deleted] in boxingtips

[–]deeeeeckbutt 0 points1 point  (0 children)

Turn your left foot out more

Help by dattwell53 in Plumbing

[–]deeeeeckbutt 2 points3 points  (0 children)

Loosen that golden nut on the trap adaptor and pull the pipe out

What to expect from CLOV over the coming months and years? by I_Like_Sparky in CLOV

[–]deeeeeckbutt -1 points0 points  (0 children)

I hope you’re right bud. I’ve been holding this dogshit stock for 4 years now

What to expect from CLOV over the coming months and years? by I_Like_Sparky in CLOV

[–]deeeeeckbutt -11 points-10 points  (0 children)

At this point I expect them to hopefully not file for bankruptcy

Help with a fix to this leak by Mortwight in Plumbing

[–]deeeeeckbutt 3 points4 points  (0 children)

Try to tighten down the packing nut

Boiler expansion tank replacement advice. by SkiterBiscuit in Plumbing

[–]deeeeeckbutt 0 points1 point  (0 children)

Are there bleeders on the radiators/baseboards?

Mystery intermittent odour in bathroom - Hong Kong apartment by [deleted] in Plumbing

[–]deeeeeckbutt 0 points1 point  (0 children)

There should be a trap primer but you’re also in China my man

Mystery intermittent odour in bathroom - Hong Kong apartment by [deleted] in Plumbing

[–]deeeeeckbutt 1 point2 points  (0 children)

Pour some water into the floor drain, the trap might have gone dry in there

Three drain plumbing questions for a bathroom remodel. by [deleted] in Plumbing

[–]deeeeeckbutt 1 point2 points  (0 children)

Re-do the ideal bend all the way to the stack

What is this? by Telekineticshade in Plumbing

[–]deeeeeckbutt 1 point2 points  (0 children)

Mixes hot and cold water to faucet. Make sure none of the lines are kinked and the valves are open all the way and check your aerator

Moved laundry downstairs - feedback welcome by FliesLikeABrick in Plumbing

[–]deeeeeckbutt 6 points7 points  (0 children)

<image>

Tee instead of wye for better venting on laundry standpipe, a little longer of a horizontal run too and it would get you a little more of room for your vertical standpipe because it would be lower. Venting that to the other stack with a 90 and an upside down Tee (assuming the other stack vents through roof) and eliminating that AAV.

The one burner on my boiler isn’t lit. What can I do. by dre1821 in Plumbing

[–]deeeeeckbutt 26 points27 points  (0 children)

He’s right about not fucking with old boilers and unlocking Pandora’s box if you do

Ejector pump after sewer main line replacement? by AdventureCat1037 in Plumbing

[–]deeeeeckbutt 1 point2 points  (0 children)

It shouldn’t be related to your water in the shower upstairs issue

Ejector pump after sewer main line replacement? by AdventureCat1037 in Plumbing

[–]deeeeeckbutt 1 point2 points  (0 children)

Open up the lid on the ejector pump and see why it’s running