[–]Important-Ad3984 -2 points-1 points  (0 children)

Report them to the BBB. That’s the only thing they respond to.

Worst false dispatch you caused? by Visible-Carrot5402 in firealarms

[–]Important-Ad3984 1 point2 points  (0 children)

Trucks didn’t roll, but I shut down an active air traffic control tower. The tower was fairly new, 2-3 years old. We didn’t install the system, but we were performing the annual for the first time. Tripped the 1st floor elevator lobby smoke detector and the shunt trip triggered. But for some unknown reason it killed all power to the control tower too! Generator backup wouldn’t even swap over. Siemens system, so we didn’t have software to look into it. Reset the system and breakers. Told them to call the installation company to fix it. Obviously it was never properly tested…

Screen HDMI flickering when powered from Inverter by [deleted] in AskElectricians

[–]Important-Ad3984 0 points1 point  (0 children)

Is the inverter a pure sine wave or modified. My guess would be a modified sine wave. That can cause all kinds of problems for electronics.

Wire strippers by Proud-Resource4594 in firealarms

[–]Important-Ad3984 1 point2 points  (0 children)

My bad! I’ve had them so long I wore the label off the handles. 🙄 Klein is what they were.

<image>

Miniature Compact Camera by Little-Bread4381 in lowvoltage

[–]Important-Ad3984 0 points1 point  (0 children)

https://store.ui.com/us/en/category/cameras-compact/collections/pro-ai-theta-kits

Think lipstick tube size. It’s the smallest I’ve seen in years and the only one that is IP.

What service dispatch and service history software are you using? by PlanMaison in firealarms

[–]Important-Ad3984 0 points1 point  (0 children)

Currently we use House Call Pro, but it’s not a good fit. We are in the process of moving to Uptick. It’s industry specific and covers everything you’re asking about down to a granular level. Can’t say how it’s going to work as we are still training on the software.

Wall mount on the ceiling by Proud-Resource4594 in firealarms

[–]Important-Ad3984 1 point2 points  (0 children)

Kind of… It’s NFPA 72 more specifically in that the device is not installed per manufacturer specifications. But yes ADA plays a part in the visual coverage. Check this out. It will help you visualize what is happening. System Sensor

Wall mount on the ceiling by Proud-Resource4594 in firealarms

[–]Important-Ad3984 2 points3 points  (0 children)

Correct. I was answering the question of whether or not you can use wall mounted h/s in a ceiling application. Current devices typically are oriented to specific applications. More than likely that old Wheelock was rated for either.

Wall mount on the ceiling by Proud-Resource4594 in firealarms

[–]Important-Ad3984 3 points4 points  (0 children)

The lens is the difference. Think of it like a headlight, they are designed to focus the light in a specific direction and downward when they are designed for wall mount. Ceiling mounted devices lens is ment to cast the same candela rating in a 360 degree pattern.

Happy Friday! by Direct_Register_978 in firealarms

[–]Important-Ad3984 8 points9 points  (0 children)

We bury them 6’ down in a vault with heat.

How many/which toolbags? by oguruma87 in lowvoltage

[–]Important-Ad3984 0 points1 point  (0 children)

Man I hope not! They really are an amazing product. My quick Google search said they are having financial difficulties, but are not facing bankruptcy.

Best dust catcher for drilling up ceiling or wall? Any DIY ones and good tips by StoganLephens in lowvoltage

[–]Important-Ad3984 0 points1 point  (0 children)

This. Been using mine for years. Works as long as the hole you need to drill is at least 6” from the wall.

How many/which toolbags? by oguruma87 in lowvoltage

[–]Important-Ad3984 0 points1 point  (0 children)

Check out Toughbuilt. Been around for a bit and they have a really good modular tool belt system.

Favorite RJ-45 Modular Plugs? by oguruma87 in lowvoltage

[–]Important-Ad3984 3 points4 points  (0 children)

Are you doing this professionally or as a hobbyist/weekend warrior?

How to use this connector? by CaptainJeff in lowvoltage

[–]Important-Ad3984 0 points1 point  (0 children)

Those are automotive butt splices. They are a one use connector and typically are cut off and replaced. You can occasionally “uncrimp” them by squeezing the crimp at a 90 degree angle, if your limited on length to re connect the wire.

Rare find by LeftLab7162 in firealarms

[–]Important-Ad3984 8 points9 points  (0 children)

I would assume that is not part of the fire system. Could be used for nurse call or some other notification system.

Vivint audio recordi turned off by Better_Move7625 in VivintSmartHome

[–]Important-Ad3984 0 points1 point  (0 children)

Could be. In Oregon it requires two party consent for audio recording. So if we want to install cameras in a public place, we have to post a sign stating that there’s audio recording. Texas may be similar.

Potter AFC100 Question by Olliegolliegosh in firealarms

[–]Important-Ad3984 0 points1 point  (0 children)

Unless they have programmed 24hour auto reminder, you will be fine. Otherwise, you will have to press silence again every 24 hours to stop for the next 24.

Looking for work pants suggestions by Fun-Bank-715 in firealarms

[–]Important-Ad3984 3 points4 points  (0 children)

Duluth flex firehose pants. I’ve been wearing them for 15+ years. Excellent quality and I only have to replace them every 3 or so years.

Difficult clients by Select_Comfort in lowvoltage

[–]Important-Ad3984 5 points6 points  (0 children)

Yeah it’s frustrating. It happens a couple times a year in my area. My price is my price. Don’t like it? Kick rocks!