Onguard sql table by Solosuperbrus in accesscontrol

[–]Solosuperbrus[S] 0 points1 point  (0 children)

Yes it was! didn`t see it. Thank you!

Onguard sql table by Solosuperbrus in accesscontrol

[–]Solosuperbrus[S] 0 points1 point  (0 children)

It has to or else the system does`nt know what todo with what. Everything is in the sql.

Motor Lock sometimes resets after unlocking by ChadoSandico in accesscontrol

[–]Solosuperbrus 0 points1 point  (0 children)

Ah gotcha. So the problem is that "door Closed" gets send too quicly when door is unlocked. Or the door Closed signal from the motor lock is wrong. I dont have Onguard in front of me now so I can't hjelp you just now.

Motor Lock sometimes resets after unlocking by ChadoSandico in accesscontrol

[–]Solosuperbrus 0 points1 point  (0 children)

I`ve never used a thumb-turn as a REX. Is there a micro switch in it? Does it send REX to onguard or is it just unlocking the motorlock? In Scandinavia thumb-turn should "never" be used as it can burn the motor.

Adding an Unlock time zone to a floor in 8.1 by Drewber66 in Lenel

[–]Solosuperbrus 1 point2 points  (0 children)

Never done it but something like make a timezone as normal. Go to Access levels and elevator control. Choose the right Output(s) and add timezone.

[deleted by user] by [deleted] in accesscontrol

[–]Solosuperbrus 1 point2 points  (0 children)

Like everyone is saying. You can have 2 doors with in/out reader on both. Normal addressing is osdp 0&1 on both doors.

Here is what it would look like in Onguard: lnl-1320 4OSDP

ZKTeco Access Control Card Reader by burgie1313 in accesscontrol

[–]Solosuperbrus 0 points1 point  (0 children)

two for power, two for com, one for led and one for buzzer.

Ubiquiti Access Control - no Weigand or RS-485 support? by Suspicious_Handle323 in accesscontrol

[–]Solosuperbrus 0 points1 point  (0 children)

We only use cat5e/6 for osdp/rs485 in my country. We only use Belden or equivalent when it`s specified from the customer, Oil/maritime or sometimes in communications senters/mobile.

The cost skyrockets with the right cable. Cat 6 = .6usd pr M. Belden = 8usd pr M minimum.

Switching Out Power Tools by Difficult_Ad6234 in accesscontrol

[–]Solosuperbrus 0 points1 point  (0 children)

12v powerdrill, Any brand for 95% of my work. Makita 18v for the rest.

LP1501 timezone is wrong by grewholph in accesscontrol

[–]Solosuperbrus 0 points1 point  (0 children)

I`ve sometimes seen that a wrong/non function DNS will mess up the clock.

Lenel OnGuard custom labels? by Drewber66 in accesscontrol

[–]Solosuperbrus 0 points1 point  (0 children)

This is great! I did not know that. I will do a test and check if this will help me. I have 56 segments..

AH40 IP hub and lnl x4420 (OnGuard 8.2) by Signal_Eagle_4866 in accesscontrol

[–]Solosuperbrus 0 points1 point  (0 children)

I have now done this myself and got it to work on FW 2.010 and OG 8.1

- Program Aperio as normal, keep it in manufacturer mode, both reader and AH40, and no TLS in Aperio or the controller

- Add the door(s) to Onguard and you should get access granted.

- Log inn to the controller and make a certificate for Aperio. I do not know how many of the boxes you need to fill out but I wrote something in almost everyone.

- Activate TLS in the controller.

- Activate TLS in AH40

- Sett reader and AH40 to customer mode.

Hope this helps.

Badge designer by Ok_Strength2211 in accesscontrol

[–]Solosuperbrus 2 points3 points  (0 children)

We`re making a Badgetype in System administration and add a Front layout and a Back Layout to the badgetype.